3T MR of the prostate: Reducing susceptibility gradients by inflating the endorectal coil with a barium sulfate suspension

Yael Rosen, B. Nicolas Bloch, Robert E. Lenkinski, Robert L. Greenman, Robert P. Marquis, Neil M. Rofsky

Research output: Contribution to journalArticle

47 Citations (Scopus)

Abstract

Most prostate MRI/MRS examinations are performed with an endorectal coil inflated with air, leading to an air-tissue interface that induces magnetic susceptibility gradients within the gland. Inflation of the coil with a barium sulfate suspension is described and compared to inflation with air or liquid perfluorocarbon (PFC). The B0 field in the prostate gland was mapped for five healthy volunteers when the endorectal coil was inflated with each of the three agents. A marked decrease in the posterior-anterior (P-A) field gradient and a significant improvement in field homogeneity were evident in the presence of a barium suspension and PFC relative to air. MRS data acquired from the prostate gland in the presence of air, PFC, and a barium suspension in the endorectal coil showed similar trends, demonstrating improvement in line-widths and spectral resolution when the barium suspension or the PFC were inflating the endorectal coil. On this basis we conclude that a barium suspension provides an available, cheap, and safe alternative to PFC, and we suggest that inflating the endorectal coil with a barium suspension should be considered for prostate MR studies, especially at high field strengths (such as 3T).

Original languageEnglish (US)
Pages (from-to)898-904
Number of pages7
JournalMagnetic Resonance in Medicine
Volume57
Issue number5
DOIs
StatePublished - May 2007

Fingerprint

Barium Sulfate
Fluorocarbons
Barium
Prostate
Suspensions
Air
Economic Inflation
Healthy Volunteers

Keywords

  • 3T MR
  • Barium
  • Endorectal coil
  • MRS
  • Prostate

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

3T MR of the prostate : Reducing susceptibility gradients by inflating the endorectal coil with a barium sulfate suspension. / Rosen, Yael; Bloch, B. Nicolas; Lenkinski, Robert E.; Greenman, Robert L.; Marquis, Robert P.; Rofsky, Neil M.

In: Magnetic Resonance in Medicine, Vol. 57, No. 5, 05.2007, p. 898-904.

Research output: Contribution to journalArticle

Rosen, Yael ; Bloch, B. Nicolas ; Lenkinski, Robert E. ; Greenman, Robert L. ; Marquis, Robert P. ; Rofsky, Neil M. / 3T MR of the prostate : Reducing susceptibility gradients by inflating the endorectal coil with a barium sulfate suspension. In: Magnetic Resonance in Medicine. 2007 ; Vol. 57, No. 5. pp. 898-904.
@article{f584c834ffe94ef4802606d6b2f28794,
title = "3T MR of the prostate: Reducing susceptibility gradients by inflating the endorectal coil with a barium sulfate suspension",
abstract = "Most prostate MRI/MRS examinations are performed with an endorectal coil inflated with air, leading to an air-tissue interface that induces magnetic susceptibility gradients within the gland. Inflation of the coil with a barium sulfate suspension is described and compared to inflation with air or liquid perfluorocarbon (PFC). The B0 field in the prostate gland was mapped for five healthy volunteers when the endorectal coil was inflated with each of the three agents. A marked decrease in the posterior-anterior (P-A) field gradient and a significant improvement in field homogeneity were evident in the presence of a barium suspension and PFC relative to air. MRS data acquired from the prostate gland in the presence of air, PFC, and a barium suspension in the endorectal coil showed similar trends, demonstrating improvement in line-widths and spectral resolution when the barium suspension or the PFC were inflating the endorectal coil. On this basis we conclude that a barium suspension provides an available, cheap, and safe alternative to PFC, and we suggest that inflating the endorectal coil with a barium suspension should be considered for prostate MR studies, especially at high field strengths (such as 3T).",
keywords = "3T MR, Barium, Endorectal coil, MRS, Prostate",
author = "Yael Rosen and Bloch, {B. Nicolas} and Lenkinski, {Robert E.} and Greenman, {Robert L.} and Marquis, {Robert P.} and Rofsky, {Neil M.}",
year = "2007",
month = "5",
doi = "10.1002/mrm.21166",
language = "English (US)",
volume = "57",
pages = "898--904",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "5",

}

TY - JOUR

T1 - 3T MR of the prostate

T2 - Reducing susceptibility gradients by inflating the endorectal coil with a barium sulfate suspension

AU - Rosen, Yael

AU - Bloch, B. Nicolas

AU - Lenkinski, Robert E.

AU - Greenman, Robert L.

AU - Marquis, Robert P.

AU - Rofsky, Neil M.

PY - 2007/5

Y1 - 2007/5

N2 - Most prostate MRI/MRS examinations are performed with an endorectal coil inflated with air, leading to an air-tissue interface that induces magnetic susceptibility gradients within the gland. Inflation of the coil with a barium sulfate suspension is described and compared to inflation with air or liquid perfluorocarbon (PFC). The B0 field in the prostate gland was mapped for five healthy volunteers when the endorectal coil was inflated with each of the three agents. A marked decrease in the posterior-anterior (P-A) field gradient and a significant improvement in field homogeneity were evident in the presence of a barium suspension and PFC relative to air. MRS data acquired from the prostate gland in the presence of air, PFC, and a barium suspension in the endorectal coil showed similar trends, demonstrating improvement in line-widths and spectral resolution when the barium suspension or the PFC were inflating the endorectal coil. On this basis we conclude that a barium suspension provides an available, cheap, and safe alternative to PFC, and we suggest that inflating the endorectal coil with a barium suspension should be considered for prostate MR studies, especially at high field strengths (such as 3T).

AB - Most prostate MRI/MRS examinations are performed with an endorectal coil inflated with air, leading to an air-tissue interface that induces magnetic susceptibility gradients within the gland. Inflation of the coil with a barium sulfate suspension is described and compared to inflation with air or liquid perfluorocarbon (PFC). The B0 field in the prostate gland was mapped for five healthy volunteers when the endorectal coil was inflated with each of the three agents. A marked decrease in the posterior-anterior (P-A) field gradient and a significant improvement in field homogeneity were evident in the presence of a barium suspension and PFC relative to air. MRS data acquired from the prostate gland in the presence of air, PFC, and a barium suspension in the endorectal coil showed similar trends, demonstrating improvement in line-widths and spectral resolution when the barium suspension or the PFC were inflating the endorectal coil. On this basis we conclude that a barium suspension provides an available, cheap, and safe alternative to PFC, and we suggest that inflating the endorectal coil with a barium suspension should be considered for prostate MR studies, especially at high field strengths (such as 3T).

KW - 3T MR

KW - Barium

KW - Endorectal coil

KW - MRS

KW - Prostate

UR - http://www.scopus.com/inward/record.url?scp=34248166142&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34248166142&partnerID=8YFLogxK

U2 - 10.1002/mrm.21166

DO - 10.1002/mrm.21166

M3 - Article

C2 - 17457870

AN - SCOPUS:34248166142

VL - 57

SP - 898

EP - 904

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 5

ER -