A computational model for stress reduction at the skin-implant interface of osseointegrated prostheses

Srinivasu Yerneni, Yasin Dhaher, Todd A. Kuiken

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Osseointegrated implants (OI)s for transfemoral prosthetic attachment offer amputees an alternative to the traditional socket attachment. Potential benefits include a natural transfer of loads directly to the skeleton via the percutaneous abutment, relief of pain and discomfort of residual limb soft tissues by eliminating sockets, increased sensory feedback, and improved function. Despite the benefits, the skin-implant interface remains a critical limitation, as it is highly prone to bacterial infection. One approach to improve clinical outcomes is to minimize stress concentrations at the skin-implant interface due to shear loading, reducing soft tissue breakdown and subsequent risk of infection. We hypothesized that broadening the bone base at the distal end of the femur would provide added surface area for skin adhesion and reduce stresses at the skin-implant interface. We tested this hypothesis using finite element models of an OI in a residual limb. Results showed a dramatic decrease in stress reduction, with up to ∼90% decrease in stresses at the skin-implant interface as cortical bone thickness increased from 2 to 8 mm. The findings in this study suggests that surgical techniques could stabilize the skin-implant interface, thus enhancing a skin-to-bone seal around the percutaneous device and minimizing infection.

Original languageEnglish (US)
Pages (from-to)911-917
Number of pages7
JournalJournal of Biomedical Materials Research - Part A
Volume100 A
Issue number4
DOIs
StatePublished - Apr 1 2012
Externally publishedYes

Fingerprint

Prosthetics
Skin
Bone
Sensory feedback
Tissue
Seals
Stress concentration
Adhesion

Keywords

  • finite
  • osseointegration
  • prostheses
  • skin-implant
  • stresses

ASJC Scopus subject areas

  • Ceramics and Composites
  • Biomaterials
  • Biomedical Engineering
  • Metals and Alloys

Cite this

A computational model for stress reduction at the skin-implant interface of osseointegrated prostheses. / Yerneni, Srinivasu; Dhaher, Yasin; Kuiken, Todd A.

In: Journal of Biomedical Materials Research - Part A, Vol. 100 A, No. 4, 01.04.2012, p. 911-917.

Research output: Contribution to journalArticle

@article{6930a0d6afec460fa2ae463a1872ee63,
title = "A computational model for stress reduction at the skin-implant interface of osseointegrated prostheses",
abstract = "Osseointegrated implants (OI)s for transfemoral prosthetic attachment offer amputees an alternative to the traditional socket attachment. Potential benefits include a natural transfer of loads directly to the skeleton via the percutaneous abutment, relief of pain and discomfort of residual limb soft tissues by eliminating sockets, increased sensory feedback, and improved function. Despite the benefits, the skin-implant interface remains a critical limitation, as it is highly prone to bacterial infection. One approach to improve clinical outcomes is to minimize stress concentrations at the skin-implant interface due to shear loading, reducing soft tissue breakdown and subsequent risk of infection. We hypothesized that broadening the bone base at the distal end of the femur would provide added surface area for skin adhesion and reduce stresses at the skin-implant interface. We tested this hypothesis using finite element models of an OI in a residual limb. Results showed a dramatic decrease in stress reduction, with up to ∼90{\%} decrease in stresses at the skin-implant interface as cortical bone thickness increased from 2 to 8 mm. The findings in this study suggests that surgical techniques could stabilize the skin-implant interface, thus enhancing a skin-to-bone seal around the percutaneous device and minimizing infection.",
keywords = "finite, osseointegration, prostheses, skin-implant, stresses",
author = "Srinivasu Yerneni and Yasin Dhaher and Kuiken, {Todd A.}",
year = "2012",
month = "4",
day = "1",
doi = "10.1002/jbm.a.34028",
language = "English (US)",
volume = "100 A",
pages = "911--917",
journal = "Journal of Biomedical Materials Research - Part A",
issn = "0021-9304",
publisher = "John Wiley and Sons Inc.",
number = "4",

}

TY - JOUR

T1 - A computational model for stress reduction at the skin-implant interface of osseointegrated prostheses

AU - Yerneni, Srinivasu

AU - Dhaher, Yasin

AU - Kuiken, Todd A.

PY - 2012/4/1

Y1 - 2012/4/1

N2 - Osseointegrated implants (OI)s for transfemoral prosthetic attachment offer amputees an alternative to the traditional socket attachment. Potential benefits include a natural transfer of loads directly to the skeleton via the percutaneous abutment, relief of pain and discomfort of residual limb soft tissues by eliminating sockets, increased sensory feedback, and improved function. Despite the benefits, the skin-implant interface remains a critical limitation, as it is highly prone to bacterial infection. One approach to improve clinical outcomes is to minimize stress concentrations at the skin-implant interface due to shear loading, reducing soft tissue breakdown and subsequent risk of infection. We hypothesized that broadening the bone base at the distal end of the femur would provide added surface area for skin adhesion and reduce stresses at the skin-implant interface. We tested this hypothesis using finite element models of an OI in a residual limb. Results showed a dramatic decrease in stress reduction, with up to ∼90% decrease in stresses at the skin-implant interface as cortical bone thickness increased from 2 to 8 mm. The findings in this study suggests that surgical techniques could stabilize the skin-implant interface, thus enhancing a skin-to-bone seal around the percutaneous device and minimizing infection.

AB - Osseointegrated implants (OI)s for transfemoral prosthetic attachment offer amputees an alternative to the traditional socket attachment. Potential benefits include a natural transfer of loads directly to the skeleton via the percutaneous abutment, relief of pain and discomfort of residual limb soft tissues by eliminating sockets, increased sensory feedback, and improved function. Despite the benefits, the skin-implant interface remains a critical limitation, as it is highly prone to bacterial infection. One approach to improve clinical outcomes is to minimize stress concentrations at the skin-implant interface due to shear loading, reducing soft tissue breakdown and subsequent risk of infection. We hypothesized that broadening the bone base at the distal end of the femur would provide added surface area for skin adhesion and reduce stresses at the skin-implant interface. We tested this hypothesis using finite element models of an OI in a residual limb. Results showed a dramatic decrease in stress reduction, with up to ∼90% decrease in stresses at the skin-implant interface as cortical bone thickness increased from 2 to 8 mm. The findings in this study suggests that surgical techniques could stabilize the skin-implant interface, thus enhancing a skin-to-bone seal around the percutaneous device and minimizing infection.

KW - finite

KW - osseointegration

KW - prostheses

KW - skin-implant

KW - stresses

UR - http://www.scopus.com/inward/record.url?scp=84857363870&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84857363870&partnerID=8YFLogxK

U2 - 10.1002/jbm.a.34028

DO - 10.1002/jbm.a.34028

M3 - Article

C2 - 22275149

AN - SCOPUS:84857363870

VL - 100 A

SP - 911

EP - 917

JO - Journal of Biomedical Materials Research - Part A

JF - Journal of Biomedical Materials Research - Part A

SN - 0021-9304

IS - 4

ER -