A Fast, Effective Filtering Method for Improving Clinical Pulsed Arterial Spin Labeling MRI

Huan Tan, Joseph A Maldjian, Jeffrey M. Pollock, Jonathan H. Burdette, Lucie Y. Yang, Andrew R. Deibler, Robert A. Kraft

Research output: Contribution to journalArticle

28 Citations (Scopus)

Abstract

Purpose: To evaluate the effectiveness of a fully automated postprocessing filter algorithm in pulsed arterial spin labeling (PASL) MRI perfusion images in a large clinical population. Materials and Methods: A mean and standard deviation- based filter was implemented to remove outliers in the set of perfusion-weighted images (control - label) before being averaged and scaled to quantitative cerebral blood flow (CBF) maps. Filtered and unfiltered CBF maps from 200 randomly selected clinical cases were assessed by four blinded raters to evaluate the effectiveness of the filter. Results: The filter salvaged many studies deemed uninter- pretable as a result of motion artifacts, transient gradient, and/or radiofrequency instabilities, and unexpected dis- ruption of data acquisition by the technologist to commu- nicate with the patient. The filtered CBF maps contained significantly (P 0.05) fewer artifacts and were more inter- pretable than unfiltered CBF maps as determined by one- tail paired t-test. Conclusion: Variations in MR perfusion signal related to patient motion, system instability, or disruption of the steady state can introduce artifacts in the CBF maps that can be significantly reduced by postprocessing filtering. Diagnostic quality of the clinical perfusion images can be improved by performing selective averaging without a sig- nificant loss in perfusion signal-to-noise ratio.

Original languageEnglish (US)
Pages (from-to)1134-1139
Number of pages6
JournalJournal of Magnetic Resonance Imaging
Volume29
Issue number5
DOIs
StatePublished - May 1 2009

Fingerprint

Cerebrovascular Circulation
Perfusion
Artifacts
Signal-To-Noise Ratio
Population

Keywords

  • Arterial spin labeling
  • Clinical perfusion MRI
  • PASL filtering

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

A Fast, Effective Filtering Method for Improving Clinical Pulsed Arterial Spin Labeling MRI. / Tan, Huan; Maldjian, Joseph A; Pollock, Jeffrey M.; Burdette, Jonathan H.; Yang, Lucie Y.; Deibler, Andrew R.; Kraft, Robert A.

In: Journal of Magnetic Resonance Imaging, Vol. 29, No. 5, 01.05.2009, p. 1134-1139.

Research output: Contribution to journalArticle

Tan, Huan ; Maldjian, Joseph A ; Pollock, Jeffrey M. ; Burdette, Jonathan H. ; Yang, Lucie Y. ; Deibler, Andrew R. ; Kraft, Robert A. / A Fast, Effective Filtering Method for Improving Clinical Pulsed Arterial Spin Labeling MRI. In: Journal of Magnetic Resonance Imaging. 2009 ; Vol. 29, No. 5. pp. 1134-1139.
@article{39d01b9d8397474997093efadfd71dfa,
title = "A Fast, Effective Filtering Method for Improving Clinical Pulsed Arterial Spin Labeling MRI",
abstract = "Purpose: To evaluate the effectiveness of a fully automated postprocessing filter algorithm in pulsed arterial spin labeling (PASL) MRI perfusion images in a large clinical population. Materials and Methods: A mean and standard deviation- based filter was implemented to remove outliers in the set of perfusion-weighted images (control - label) before being averaged and scaled to quantitative cerebral blood flow (CBF) maps. Filtered and unfiltered CBF maps from 200 randomly selected clinical cases were assessed by four blinded raters to evaluate the effectiveness of the filter. Results: The filter salvaged many studies deemed uninter- pretable as a result of motion artifacts, transient gradient, and/or radiofrequency instabilities, and unexpected dis- ruption of data acquisition by the technologist to commu- nicate with the patient. The filtered CBF maps contained significantly (P 0.05) fewer artifacts and were more inter- pretable than unfiltered CBF maps as determined by one- tail paired t-test. Conclusion: Variations in MR perfusion signal related to patient motion, system instability, or disruption of the steady state can introduce artifacts in the CBF maps that can be significantly reduced by postprocessing filtering. Diagnostic quality of the clinical perfusion images can be improved by performing selective averaging without a sig- nificant loss in perfusion signal-to-noise ratio.",
keywords = "Arterial spin labeling, Clinical perfusion MRI, PASL filtering",
author = "Huan Tan and Maldjian, {Joseph A} and Pollock, {Jeffrey M.} and Burdette, {Jonathan H.} and Yang, {Lucie Y.} and Deibler, {Andrew R.} and Kraft, {Robert A.}",
year = "2009",
month = "5",
day = "1",
doi = "10.1002/jmri.21721",
language = "English (US)",
volume = "29",
pages = "1134--1139",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "5",

}

TY - JOUR

T1 - A Fast, Effective Filtering Method for Improving Clinical Pulsed Arterial Spin Labeling MRI

AU - Tan, Huan

AU - Maldjian, Joseph A

AU - Pollock, Jeffrey M.

AU - Burdette, Jonathan H.

AU - Yang, Lucie Y.

AU - Deibler, Andrew R.

AU - Kraft, Robert A.

PY - 2009/5/1

Y1 - 2009/5/1

N2 - Purpose: To evaluate the effectiveness of a fully automated postprocessing filter algorithm in pulsed arterial spin labeling (PASL) MRI perfusion images in a large clinical population. Materials and Methods: A mean and standard deviation- based filter was implemented to remove outliers in the set of perfusion-weighted images (control - label) before being averaged and scaled to quantitative cerebral blood flow (CBF) maps. Filtered and unfiltered CBF maps from 200 randomly selected clinical cases were assessed by four blinded raters to evaluate the effectiveness of the filter. Results: The filter salvaged many studies deemed uninter- pretable as a result of motion artifacts, transient gradient, and/or radiofrequency instabilities, and unexpected dis- ruption of data acquisition by the technologist to commu- nicate with the patient. The filtered CBF maps contained significantly (P 0.05) fewer artifacts and were more inter- pretable than unfiltered CBF maps as determined by one- tail paired t-test. Conclusion: Variations in MR perfusion signal related to patient motion, system instability, or disruption of the steady state can introduce artifacts in the CBF maps that can be significantly reduced by postprocessing filtering. Diagnostic quality of the clinical perfusion images can be improved by performing selective averaging without a sig- nificant loss in perfusion signal-to-noise ratio.

AB - Purpose: To evaluate the effectiveness of a fully automated postprocessing filter algorithm in pulsed arterial spin labeling (PASL) MRI perfusion images in a large clinical population. Materials and Methods: A mean and standard deviation- based filter was implemented to remove outliers in the set of perfusion-weighted images (control - label) before being averaged and scaled to quantitative cerebral blood flow (CBF) maps. Filtered and unfiltered CBF maps from 200 randomly selected clinical cases were assessed by four blinded raters to evaluate the effectiveness of the filter. Results: The filter salvaged many studies deemed uninter- pretable as a result of motion artifacts, transient gradient, and/or radiofrequency instabilities, and unexpected dis- ruption of data acquisition by the technologist to commu- nicate with the patient. The filtered CBF maps contained significantly (P 0.05) fewer artifacts and were more inter- pretable than unfiltered CBF maps as determined by one- tail paired t-test. Conclusion: Variations in MR perfusion signal related to patient motion, system instability, or disruption of the steady state can introduce artifacts in the CBF maps that can be significantly reduced by postprocessing filtering. Diagnostic quality of the clinical perfusion images can be improved by performing selective averaging without a sig- nificant loss in perfusion signal-to-noise ratio.

KW - Arterial spin labeling

KW - Clinical perfusion MRI

KW - PASL filtering

UR - http://www.scopus.com/inward/record.url?scp=66149090768&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=66149090768&partnerID=8YFLogxK

U2 - 10.1002/jmri.21721

DO - 10.1002/jmri.21721

M3 - Article

VL - 29

SP - 1134

EP - 1139

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 5

ER -