A rapid and sensitive technique for the detection of Fc receptors on macrophages

A. J. Schroit, E. Kedar, Ruth Gallily

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

A rapid and sensitive technique for the production of macrophage EA rosettes employing centrifugal sedimentation of opsonized erythrocytes is described. Using this method, a sensitive rosette formation-inhibition assay for the determination of anti-macrophage antibody titers has been developed.

Original languageEnglish (US)
Pages (from-to)163-170
Number of pages8
JournalJournal of Immunological Methods
Volume12
Issue number1-2
DOIs
StatePublished - 1976

Fingerprint

Fc Receptors
Macrophages
Rosette Formation
Blood Sedimentation
Anti-Idiotypic Antibodies

ASJC Scopus subject areas

  • Biotechnology
  • Immunology

Cite this

A rapid and sensitive technique for the detection of Fc receptors on macrophages. / Schroit, A. J.; Kedar, E.; Gallily, Ruth.

In: Journal of Immunological Methods, Vol. 12, No. 1-2, 1976, p. 163-170.

Research output: Contribution to journalArticle

Schroit, A. J. ; Kedar, E. ; Gallily, Ruth. / A rapid and sensitive technique for the detection of Fc receptors on macrophages. In: Journal of Immunological Methods. 1976 ; Vol. 12, No. 1-2. pp. 163-170.
@article{825b4df79dad4a72b84841a5403d0d5d,
title = "A rapid and sensitive technique for the detection of Fc receptors on macrophages",
abstract = "A rapid and sensitive technique for the production of macrophage EA rosettes employing centrifugal sedimentation of opsonized erythrocytes is described. Using this method, a sensitive rosette formation-inhibition assay for the determination of anti-macrophage antibody titers has been developed.",
author = "Schroit, {A. J.} and E. Kedar and Ruth Gallily",
year = "1976",
doi = "10.1016/0022-1759(76)90106-X",
language = "English (US)",
volume = "12",
pages = "163--170",
journal = "Journal of Immunological Methods",
issn = "0022-1759",
publisher = "Elsevier",
number = "1-2",

}

TY - JOUR

T1 - A rapid and sensitive technique for the detection of Fc receptors on macrophages

AU - Schroit, A. J.

AU - Kedar, E.

AU - Gallily, Ruth

PY - 1976

Y1 - 1976

N2 - A rapid and sensitive technique for the production of macrophage EA rosettes employing centrifugal sedimentation of opsonized erythrocytes is described. Using this method, a sensitive rosette formation-inhibition assay for the determination of anti-macrophage antibody titers has been developed.

AB - A rapid and sensitive technique for the production of macrophage EA rosettes employing centrifugal sedimentation of opsonized erythrocytes is described. Using this method, a sensitive rosette formation-inhibition assay for the determination of anti-macrophage antibody titers has been developed.

UR - http://www.scopus.com/inward/record.url?scp=0017076738&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0017076738&partnerID=8YFLogxK

U2 - 10.1016/0022-1759(76)90106-X

DO - 10.1016/0022-1759(76)90106-X

M3 - Article

C2 - 792347

AN - SCOPUS:0017076738

VL - 12

SP - 163

EP - 170

JO - Journal of Immunological Methods

JF - Journal of Immunological Methods

SN - 0022-1759

IS - 1-2

ER -