Accuracy of clinical detection of INO in MS: Corroboration with quantitative infrared oculography

T. C. Frohman, Elliot Frohman, Padraig E O'Suilleabhain, A. Salter, Richard B Dewey, Robert N Hogan, S. Galetta, A. G. Lee, D. Straumann, J. Noseworthy, D. Zee, J. Corbett, J. Corboy, V. M. Rivera, P. D. Kramer

Research output: Contribution to journalArticle

37 Citations (Scopus)

Abstract

The authors compared the accuracy of clinical detection (by 279 physician observers) of internuclear ophthalmoparesis (INO) with that of quantitative infrared oculography. For the patients with mild adduction slowing, INO was not identified by 71%. Intermediate dysconjugacy was not detected by 25% of the evaluators. In the most severe cases, INO was not identified by only 6%. Oculographic techniques significantly enhance the precision of INO detection compared to the clinical exam.

Original languageEnglish (US)
Pages (from-to)848-850
Number of pages3
JournalNeurology
Volume61
Issue number6
StatePublished - Sep 23 2003

Fingerprint

Ophthalmoplegia
Physicians

ASJC Scopus subject areas

  • Neuroscience(all)

Cite this

Accuracy of clinical detection of INO in MS : Corroboration with quantitative infrared oculography. / Frohman, T. C.; Frohman, Elliot; O'Suilleabhain, Padraig E; Salter, A.; Dewey, Richard B; Hogan, Robert N; Galetta, S.; Lee, A. G.; Straumann, D.; Noseworthy, J.; Zee, D.; Corbett, J.; Corboy, J.; Rivera, V. M.; Kramer, P. D.

In: Neurology, Vol. 61, No. 6, 23.09.2003, p. 848-850.

Research output: Contribution to journalArticle

Frohman, TC, Frohman, E, O'Suilleabhain, PE, Salter, A, Dewey, RB, Hogan, RN, Galetta, S, Lee, AG, Straumann, D, Noseworthy, J, Zee, D, Corbett, J, Corboy, J, Rivera, VM & Kramer, PD 2003, 'Accuracy of clinical detection of INO in MS: Corroboration with quantitative infrared oculography', Neurology, vol. 61, no. 6, pp. 848-850.
Frohman, T. C. ; Frohman, Elliot ; O'Suilleabhain, Padraig E ; Salter, A. ; Dewey, Richard B ; Hogan, Robert N ; Galetta, S. ; Lee, A. G. ; Straumann, D. ; Noseworthy, J. ; Zee, D. ; Corbett, J. ; Corboy, J. ; Rivera, V. M. ; Kramer, P. D. / Accuracy of clinical detection of INO in MS : Corroboration with quantitative infrared oculography. In: Neurology. 2003 ; Vol. 61, No. 6. pp. 848-850.
@article{d726461172b64ba8a715fadf9b79034d,
title = "Accuracy of clinical detection of INO in MS: Corroboration with quantitative infrared oculography",
abstract = "The authors compared the accuracy of clinical detection (by 279 physician observers) of internuclear ophthalmoparesis (INO) with that of quantitative infrared oculography. For the patients with mild adduction slowing, INO was not identified by 71{\%}. Intermediate dysconjugacy was not detected by 25{\%} of the evaluators. In the most severe cases, INO was not identified by only 6{\%}. Oculographic techniques significantly enhance the precision of INO detection compared to the clinical exam.",
author = "Frohman, {T. C.} and Elliot Frohman and O'Suilleabhain, {Padraig E} and A. Salter and Dewey, {Richard B} and Hogan, {Robert N} and S. Galetta and Lee, {A. G.} and D. Straumann and J. Noseworthy and D. Zee and J. Corbett and J. Corboy and Rivera, {V. M.} and Kramer, {P. D.}",
year = "2003",
month = "9",
day = "23",
language = "English (US)",
volume = "61",
pages = "848--850",
journal = "Neurology",
issn = "0028-3878",
publisher = "Lippincott Williams and Wilkins",
number = "6",

}

TY - JOUR

T1 - Accuracy of clinical detection of INO in MS

T2 - Corroboration with quantitative infrared oculography

AU - Frohman, T. C.

AU - Frohman, Elliot

AU - O'Suilleabhain, Padraig E

AU - Salter, A.

AU - Dewey, Richard B

AU - Hogan, Robert N

AU - Galetta, S.

AU - Lee, A. G.

AU - Straumann, D.

AU - Noseworthy, J.

AU - Zee, D.

AU - Corbett, J.

AU - Corboy, J.

AU - Rivera, V. M.

AU - Kramer, P. D.

PY - 2003/9/23

Y1 - 2003/9/23

N2 - The authors compared the accuracy of clinical detection (by 279 physician observers) of internuclear ophthalmoparesis (INO) with that of quantitative infrared oculography. For the patients with mild adduction slowing, INO was not identified by 71%. Intermediate dysconjugacy was not detected by 25% of the evaluators. In the most severe cases, INO was not identified by only 6%. Oculographic techniques significantly enhance the precision of INO detection compared to the clinical exam.

AB - The authors compared the accuracy of clinical detection (by 279 physician observers) of internuclear ophthalmoparesis (INO) with that of quantitative infrared oculography. For the patients with mild adduction slowing, INO was not identified by 71%. Intermediate dysconjugacy was not detected by 25% of the evaluators. In the most severe cases, INO was not identified by only 6%. Oculographic techniques significantly enhance the precision of INO detection compared to the clinical exam.

UR - http://www.scopus.com/inward/record.url?scp=10744229588&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=10744229588&partnerID=8YFLogxK

M3 - Article

C2 - 14504338

AN - SCOPUS:10744229588

VL - 61

SP - 848

EP - 850

JO - Neurology

JF - Neurology

SN - 0028-3878

IS - 6

ER -