An investigation into the mechanical and aesthetic properties of new generation coated nickel-titanium wires in the as-received state and after clinical use

T. Gerard Bradley, David W. Berzins, Nicholas Valeri, Jessica Pruszynski, Theodore Eliades, Christos Katsaros

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

BACKGROUND/OBJECTIVES: The purpose of this study was to compare the mechanical, structural, and aesthetic properties of two types of aesthetic coated nickel-titanium (NiTi) wires compared with comparable regular NiTi wires in the as-received state and after clinical use. MATERIALS/METHODS: Sixty one subjects were randomly assigned to four groups (N = 61), two groups of coated wires and two groups of comparable, non-coated controls (n = 15/group). The period in the mouth ranged from 4 to 12 weeks after insertion. In total, 121 wires (61 retrieved and 60 as-received) were used in the study. The percentages of coating retention and loss were extrapolated from scans. A brief survey of five questions with three choices was given to all patients. Differential scanning calorimetry (DSC) and three-point bending tests were done on as-received and used wires. RESULTS: The surface characterization by the percentage of resin remaining indicated that most wires in both test groups lost a significant amount of coating. A patient survey indicated that this was a noticeable feature for patients. DSC analysis of the wires indicated that the metallurgical properties of the coated wires were not similar to the uncoated wires in the as-received condition. Three-point bending results indicate a wide variation in test results with large standard deviations among all the groups. LIMITATIONS: The extent of coating loss requires investigating, as do the biological properties of the detached coating. CONCLUSIONS: Both wires lost a significant amount of aesthetic coating after varying periods in the mouth. The metallurgical testing of these findings may indicate that these wires perform differently in the mouth.

Original languageEnglish (US)
Pages (from-to)290-296
Number of pages7
JournalEuropean Journal of Orthodontics
Volume36
Issue number3
DOIs
StatePublished - Jan 1 2014

Fingerprint

Esthetics
Mouth
Differential Scanning Calorimetry
nitinol
Surveys and Questionnaires

ASJC Scopus subject areas

  • Orthodontics

Cite this

An investigation into the mechanical and aesthetic properties of new generation coated nickel-titanium wires in the as-received state and after clinical use. / Bradley, T. Gerard; Berzins, David W.; Valeri, Nicholas; Pruszynski, Jessica; Eliades, Theodore; Katsaros, Christos.

In: European Journal of Orthodontics, Vol. 36, No. 3, 01.01.2014, p. 290-296.

Research output: Contribution to journalArticle

Bradley, T. Gerard ; Berzins, David W. ; Valeri, Nicholas ; Pruszynski, Jessica ; Eliades, Theodore ; Katsaros, Christos. / An investigation into the mechanical and aesthetic properties of new generation coated nickel-titanium wires in the as-received state and after clinical use. In: European Journal of Orthodontics. 2014 ; Vol. 36, No. 3. pp. 290-296.
@article{d07a6eef666e4185bab71baf25f00b6b,
title = "An investigation into the mechanical and aesthetic properties of new generation coated nickel-titanium wires in the as-received state and after clinical use",
abstract = "BACKGROUND/OBJECTIVES: The purpose of this study was to compare the mechanical, structural, and aesthetic properties of two types of aesthetic coated nickel-titanium (NiTi) wires compared with comparable regular NiTi wires in the as-received state and after clinical use. MATERIALS/METHODS: Sixty one subjects were randomly assigned to four groups (N = 61), two groups of coated wires and two groups of comparable, non-coated controls (n = 15/group). The period in the mouth ranged from 4 to 12 weeks after insertion. In total, 121 wires (61 retrieved and 60 as-received) were used in the study. The percentages of coating retention and loss were extrapolated from scans. A brief survey of five questions with three choices was given to all patients. Differential scanning calorimetry (DSC) and three-point bending tests were done on as-received and used wires. RESULTS: The surface characterization by the percentage of resin remaining indicated that most wires in both test groups lost a significant amount of coating. A patient survey indicated that this was a noticeable feature for patients. DSC analysis of the wires indicated that the metallurgical properties of the coated wires were not similar to the uncoated wires in the as-received condition. Three-point bending results indicate a wide variation in test results with large standard deviations among all the groups. LIMITATIONS: The extent of coating loss requires investigating, as do the biological properties of the detached coating. CONCLUSIONS: Both wires lost a significant amount of aesthetic coating after varying periods in the mouth. The metallurgical testing of these findings may indicate that these wires perform differently in the mouth.",
author = "Bradley, {T. Gerard} and Berzins, {David W.} and Nicholas Valeri and Jessica Pruszynski and Theodore Eliades and Christos Katsaros",
year = "2014",
month = "1",
day = "1",
doi = "10.1093/ejo/cjt048",
language = "English (US)",
volume = "36",
pages = "290--296",
journal = "European Journal of Orthodontics",
issn = "0141-5387",
publisher = "Oxford University Press",
number = "3",

}

TY - JOUR

T1 - An investigation into the mechanical and aesthetic properties of new generation coated nickel-titanium wires in the as-received state and after clinical use

AU - Bradley, T. Gerard

AU - Berzins, David W.

AU - Valeri, Nicholas

AU - Pruszynski, Jessica

AU - Eliades, Theodore

AU - Katsaros, Christos

PY - 2014/1/1

Y1 - 2014/1/1

N2 - BACKGROUND/OBJECTIVES: The purpose of this study was to compare the mechanical, structural, and aesthetic properties of two types of aesthetic coated nickel-titanium (NiTi) wires compared with comparable regular NiTi wires in the as-received state and after clinical use. MATERIALS/METHODS: Sixty one subjects were randomly assigned to four groups (N = 61), two groups of coated wires and two groups of comparable, non-coated controls (n = 15/group). The period in the mouth ranged from 4 to 12 weeks after insertion. In total, 121 wires (61 retrieved and 60 as-received) were used in the study. The percentages of coating retention and loss were extrapolated from scans. A brief survey of five questions with three choices was given to all patients. Differential scanning calorimetry (DSC) and three-point bending tests were done on as-received and used wires. RESULTS: The surface characterization by the percentage of resin remaining indicated that most wires in both test groups lost a significant amount of coating. A patient survey indicated that this was a noticeable feature for patients. DSC analysis of the wires indicated that the metallurgical properties of the coated wires were not similar to the uncoated wires in the as-received condition. Three-point bending results indicate a wide variation in test results with large standard deviations among all the groups. LIMITATIONS: The extent of coating loss requires investigating, as do the biological properties of the detached coating. CONCLUSIONS: Both wires lost a significant amount of aesthetic coating after varying periods in the mouth. The metallurgical testing of these findings may indicate that these wires perform differently in the mouth.

AB - BACKGROUND/OBJECTIVES: The purpose of this study was to compare the mechanical, structural, and aesthetic properties of two types of aesthetic coated nickel-titanium (NiTi) wires compared with comparable regular NiTi wires in the as-received state and after clinical use. MATERIALS/METHODS: Sixty one subjects were randomly assigned to four groups (N = 61), two groups of coated wires and two groups of comparable, non-coated controls (n = 15/group). The period in the mouth ranged from 4 to 12 weeks after insertion. In total, 121 wires (61 retrieved and 60 as-received) were used in the study. The percentages of coating retention and loss were extrapolated from scans. A brief survey of five questions with three choices was given to all patients. Differential scanning calorimetry (DSC) and three-point bending tests were done on as-received and used wires. RESULTS: The surface characterization by the percentage of resin remaining indicated that most wires in both test groups lost a significant amount of coating. A patient survey indicated that this was a noticeable feature for patients. DSC analysis of the wires indicated that the metallurgical properties of the coated wires were not similar to the uncoated wires in the as-received condition. Three-point bending results indicate a wide variation in test results with large standard deviations among all the groups. LIMITATIONS: The extent of coating loss requires investigating, as do the biological properties of the detached coating. CONCLUSIONS: Both wires lost a significant amount of aesthetic coating after varying periods in the mouth. The metallurgical testing of these findings may indicate that these wires perform differently in the mouth.

UR - http://www.scopus.com/inward/record.url?scp=84901461145&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84901461145&partnerID=8YFLogxK

U2 - 10.1093/ejo/cjt048

DO - 10.1093/ejo/cjt048

M3 - Article

C2 - 23873791

AN - SCOPUS:84901461145

VL - 36

SP - 290

EP - 296

JO - European Journal of Orthodontics

JF - European Journal of Orthodontics

SN - 0141-5387

IS - 3

ER -