TY - JOUR
T1 - Arthroscopic suture bridge transosseus equivalent fixation of rotator cuff tendon preserves intratendinous blood flow at the time of initial fixation
AU - Christoforetti, John J.
AU - Krupp, Ryan J.
AU - Singleton, Steven B.
AU - Kissenberth, Michael J.
AU - Cook, Chad
AU - Hawkins, Richard J.
N1 - Funding Information:
No author, their immediate family, and any research foundation with which they are affiliated have received any financial payments or other benefits from any commercial entity related to the subject of this article. The Laser Doppler flowmetry probe was provided by the Orthopaedic Research Foundation of the Carolinas for the purpose of this research project. This study was funded in part by the Orthopaedic Research Foundation of the Carolinas.
PY - 2012/4
Y1 - 2012/4
N2 - Background: Current etiologic theories concerning healing rates in rotator cuff repair have focused on the blood supply in the tendinous portion of the cuff. We currently have little information regarding the effect of our repair techniques on this critical variable. We hypothesize that intratendinous blood flow is changed during transosseus equivalent tendon fixation. Methods: Eighteen consecutive patients with rotator cuff tears amenable to double row fixation were included in the study. Each patient underwent a standard arthroscopic transosseous equivalent double row fixation procedure using the Arthrex SutureBridge technique (Arthrex, Naples, FL, USA). After tying down of the medial row, a first set of recordings was taken using a custom laser doppler flowmetry probe (Perimed, Inc., Ohio, USA). A second recording was made following securing of the lateral PushLock anchors. The data were compared to determine the overall effect on blood flow associated with this technique. Results: Summated averages for the 2 groups show a significant (44.67%) decline in the blood flow present after the second row of implants are placed (P < .01). Individual calculations for regions of the cuff tear indicate significant differences in anterior third (P = .01), middle third (P < .01), and posterior third (P = .02) of the tear after transosseous equivalent fixation. Conclusion: Completion of the construct with lateral anchors in the transosseous equivalent technique results in reduced but preserved blood flow in the tendon repair site. Further study is required to determine the implications for tendon healing. Clinical relevance: Intratendinous blood flow is a variable that should be considered when evaluating repair methods in rotator cuff surgery. Level of evidence: Level IV, Case Series, Treatment Study.
AB - Background: Current etiologic theories concerning healing rates in rotator cuff repair have focused on the blood supply in the tendinous portion of the cuff. We currently have little information regarding the effect of our repair techniques on this critical variable. We hypothesize that intratendinous blood flow is changed during transosseus equivalent tendon fixation. Methods: Eighteen consecutive patients with rotator cuff tears amenable to double row fixation were included in the study. Each patient underwent a standard arthroscopic transosseous equivalent double row fixation procedure using the Arthrex SutureBridge technique (Arthrex, Naples, FL, USA). After tying down of the medial row, a first set of recordings was taken using a custom laser doppler flowmetry probe (Perimed, Inc., Ohio, USA). A second recording was made following securing of the lateral PushLock anchors. The data were compared to determine the overall effect on blood flow associated with this technique. Results: Summated averages for the 2 groups show a significant (44.67%) decline in the blood flow present after the second row of implants are placed (P < .01). Individual calculations for regions of the cuff tear indicate significant differences in anterior third (P = .01), middle third (P < .01), and posterior third (P = .02) of the tear after transosseous equivalent fixation. Conclusion: Completion of the construct with lateral anchors in the transosseous equivalent technique results in reduced but preserved blood flow in the tendon repair site. Further study is required to determine the implications for tendon healing. Clinical relevance: Intratendinous blood flow is a variable that should be considered when evaluating repair methods in rotator cuff surgery. Level of evidence: Level IV, Case Series, Treatment Study.
KW - Blood flow
KW - Doppler
KW - Laser
KW - Rotator cuff
KW - Surgery
UR - http://www.scopus.com/inward/record.url?scp=84858335592&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84858335592&partnerID=8YFLogxK
U2 - 10.1016/j.jse.2011.02.012
DO - 10.1016/j.jse.2011.02.012
M3 - Article
C2 - 21596587
AN - SCOPUS:84858335592
SN - 1058-2746
VL - 21
SP - 523
EP - 530
JO - Journal of Shoulder and Elbow Surgery
JF - Journal of Shoulder and Elbow Surgery
IS - 4
ER -