Automated motion evaluation of left ventricular tissue from grid tagged MR images

Yeaser M. Ibrahim, Michael P Chwialkowski, Dennis P Pfeifer, Geoffrey Clarke, Jose Paraga, Ronald M Peshock

Research output: Chapter in Book/Report/Conference proceedingConference contribution

2 Citations (Scopus)

Abstract

Analysis of the left ventricular function requires accurate evaluation of segmental left ventricular wall motion. Magnetic Resonance Imaging (MRI) with magnetic tagging provides a means of determining absolute myocardial wall motion by labeling the myocardium. Manual analysis of the images is not only time consuming, but also suffers from human errors related to fatigue. In this paper we present a method to automatically track the motion of the left ventricular wall using grid-tagged MR images.

Original languageEnglish (US)
Title of host publicationProceedings of the Annual Conference on Engineering in Medicine and Biology
Place of PublicationPiscataway, NJ, United States
PublisherPubl by IEEE
Pages168-169
Number of pages2
Volume15
Editionpt 1
ISBN (Print)0780313771
StatePublished - 1993
EventProceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Society - San Diego, CA, USA
Duration: Oct 28 1993Oct 31 1993

Other

OtherProceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
CitySan Diego, CA, USA
Period10/28/9310/31/93

Fingerprint

Labeling
Fatigue of materials
Tissue
Magnetic Resonance Imaging

ASJC Scopus subject areas

  • Bioengineering

Cite this

Ibrahim, Y. M., Chwialkowski, M. P., Pfeifer, D. P., Clarke, G., Paraga, J., & Peshock, R. M. (1993). Automated motion evaluation of left ventricular tissue from grid tagged MR images. In Proceedings of the Annual Conference on Engineering in Medicine and Biology (pt 1 ed., Vol. 15, pp. 168-169). Piscataway, NJ, United States: Publ by IEEE.

Automated motion evaluation of left ventricular tissue from grid tagged MR images. / Ibrahim, Yeaser M.; Chwialkowski, Michael P; Pfeifer, Dennis P; Clarke, Geoffrey; Paraga, Jose; Peshock, Ronald M.

Proceedings of the Annual Conference on Engineering in Medicine and Biology. Vol. 15 pt 1. ed. Piscataway, NJ, United States : Publ by IEEE, 1993. p. 168-169.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Ibrahim, YM, Chwialkowski, MP, Pfeifer, DP, Clarke, G, Paraga, J & Peshock, RM 1993, Automated motion evaluation of left ventricular tissue from grid tagged MR images. in Proceedings of the Annual Conference on Engineering in Medicine and Biology. pt 1 edn, vol. 15, Publ by IEEE, Piscataway, NJ, United States, pp. 168-169, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Diego, CA, USA, 10/28/93.
Ibrahim YM, Chwialkowski MP, Pfeifer DP, Clarke G, Paraga J, Peshock RM. Automated motion evaluation of left ventricular tissue from grid tagged MR images. In Proceedings of the Annual Conference on Engineering in Medicine and Biology. pt 1 ed. Vol. 15. Piscataway, NJ, United States: Publ by IEEE. 1993. p. 168-169
Ibrahim, Yeaser M. ; Chwialkowski, Michael P ; Pfeifer, Dennis P ; Clarke, Geoffrey ; Paraga, Jose ; Peshock, Ronald M. / Automated motion evaluation of left ventricular tissue from grid tagged MR images. Proceedings of the Annual Conference on Engineering in Medicine and Biology. Vol. 15 pt 1. ed. Piscataway, NJ, United States : Publ by IEEE, 1993. pp. 168-169
@inproceedings{8db7ff52f9264439ae665e13ade3dda8,
title = "Automated motion evaluation of left ventricular tissue from grid tagged MR images",
abstract = "Analysis of the left ventricular function requires accurate evaluation of segmental left ventricular wall motion. Magnetic Resonance Imaging (MRI) with magnetic tagging provides a means of determining absolute myocardial wall motion by labeling the myocardium. Manual analysis of the images is not only time consuming, but also suffers from human errors related to fatigue. In this paper we present a method to automatically track the motion of the left ventricular wall using grid-tagged MR images.",
author = "Ibrahim, {Yeaser M.} and Chwialkowski, {Michael P} and Pfeifer, {Dennis P} and Geoffrey Clarke and Jose Paraga and Peshock, {Ronald M}",
year = "1993",
language = "English (US)",
isbn = "0780313771",
volume = "15",
pages = "168--169",
booktitle = "Proceedings of the Annual Conference on Engineering in Medicine and Biology",
publisher = "Publ by IEEE",
edition = "pt 1",

}

TY - GEN

T1 - Automated motion evaluation of left ventricular tissue from grid tagged MR images

AU - Ibrahim, Yeaser M.

AU - Chwialkowski, Michael P

AU - Pfeifer, Dennis P

AU - Clarke, Geoffrey

AU - Paraga, Jose

AU - Peshock, Ronald M

PY - 1993

Y1 - 1993

N2 - Analysis of the left ventricular function requires accurate evaluation of segmental left ventricular wall motion. Magnetic Resonance Imaging (MRI) with magnetic tagging provides a means of determining absolute myocardial wall motion by labeling the myocardium. Manual analysis of the images is not only time consuming, but also suffers from human errors related to fatigue. In this paper we present a method to automatically track the motion of the left ventricular wall using grid-tagged MR images.

AB - Analysis of the left ventricular function requires accurate evaluation of segmental left ventricular wall motion. Magnetic Resonance Imaging (MRI) with magnetic tagging provides a means of determining absolute myocardial wall motion by labeling the myocardium. Manual analysis of the images is not only time consuming, but also suffers from human errors related to fatigue. In this paper we present a method to automatically track the motion of the left ventricular wall using grid-tagged MR images.

UR - http://www.scopus.com/inward/record.url?scp=0027874673&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027874673&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:0027874673

SN - 0780313771

VL - 15

SP - 168

EP - 169

BT - Proceedings of the Annual Conference on Engineering in Medicine and Biology

PB - Publ by IEEE

CY - Piscataway, NJ, United States

ER -