Automated system for blood flow measurement using MR velocity sensitive imaging

Yaser M. Ibrahim, Michael P. Chwialkowski, Dennis P. Pfeifer, Geoffrey Clarke, Janice Kowal, Glen Wilbert, Ronald M. Penshock

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

Quantitative blood flow analysis is an important tool for the diagnosis of many diseases. Magnetic Resonance Imaging (MRI) offers a techniques for estimating pulsatile blood flow using phase difference of velocity-encoded and velocity-compensated image sequences. Here we present an automated system for quantitative analysis and visualization of blood flow and volume.

Original languageEnglish (US)
Title of host publicationProceedings of the Annual Conference on Engineering in Medicine and Biology
Place of PublicationPiscataway, NJ, United States
PublisherPubl by IEEE
Pages170-171
Number of pages2
Volume15
Editionpt 1
ISBN (Print)0780313771
StatePublished - 1993
EventProceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Society - San Diego, CA, USA
Duration: Oct 28 1993Oct 31 1993

Other

OtherProceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
CitySan Diego, CA, USA
Period10/28/9310/31/93

Fingerprint

Flow measurement
Blood
Imaging techniques
Visualization
Chemical analysis

ASJC Scopus subject areas

  • Bioengineering

Cite this

Ibrahim, Y. M., Chwialkowski, M. P., Pfeifer, D. P., Clarke, G., Kowal, J., Wilbert, G., & Penshock, R. M. (1993). Automated system for blood flow measurement using MR velocity sensitive imaging. In Proceedings of the Annual Conference on Engineering in Medicine and Biology (pt 1 ed., Vol. 15, pp. 170-171). Piscataway, NJ, United States: Publ by IEEE.

Automated system for blood flow measurement using MR velocity sensitive imaging. / Ibrahim, Yaser M.; Chwialkowski, Michael P.; Pfeifer, Dennis P.; Clarke, Geoffrey; Kowal, Janice; Wilbert, Glen; Penshock, Ronald M.

Proceedings of the Annual Conference on Engineering in Medicine and Biology. Vol. 15 pt 1. ed. Piscataway, NJ, United States : Publ by IEEE, 1993. p. 170-171.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Ibrahim, YM, Chwialkowski, MP, Pfeifer, DP, Clarke, G, Kowal, J, Wilbert, G & Penshock, RM 1993, Automated system for blood flow measurement using MR velocity sensitive imaging. in Proceedings of the Annual Conference on Engineering in Medicine and Biology. pt 1 edn, vol. 15, Publ by IEEE, Piscataway, NJ, United States, pp. 170-171, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Diego, CA, USA, 10/28/93.
Ibrahim YM, Chwialkowski MP, Pfeifer DP, Clarke G, Kowal J, Wilbert G et al. Automated system for blood flow measurement using MR velocity sensitive imaging. In Proceedings of the Annual Conference on Engineering in Medicine and Biology. pt 1 ed. Vol. 15. Piscataway, NJ, United States: Publ by IEEE. 1993. p. 170-171
Ibrahim, Yaser M. ; Chwialkowski, Michael P. ; Pfeifer, Dennis P. ; Clarke, Geoffrey ; Kowal, Janice ; Wilbert, Glen ; Penshock, Ronald M. / Automated system for blood flow measurement using MR velocity sensitive imaging. Proceedings of the Annual Conference on Engineering in Medicine and Biology. Vol. 15 pt 1. ed. Piscataway, NJ, United States : Publ by IEEE, 1993. pp. 170-171
@inproceedings{06f7caeda3e14b14b353428c843d6894,
title = "Automated system for blood flow measurement using MR velocity sensitive imaging",
abstract = "Quantitative blood flow analysis is an important tool for the diagnosis of many diseases. Magnetic Resonance Imaging (MRI) offers a techniques for estimating pulsatile blood flow using phase difference of velocity-encoded and velocity-compensated image sequences. Here we present an automated system for quantitative analysis and visualization of blood flow and volume.",
author = "Ibrahim, {Yaser M.} and Chwialkowski, {Michael P.} and Pfeifer, {Dennis P.} and Geoffrey Clarke and Janice Kowal and Glen Wilbert and Penshock, {Ronald M.}",
year = "1993",
language = "English (US)",
isbn = "0780313771",
volume = "15",
pages = "170--171",
booktitle = "Proceedings of the Annual Conference on Engineering in Medicine and Biology",
publisher = "Publ by IEEE",
edition = "pt 1",

}

TY - GEN

T1 - Automated system for blood flow measurement using MR velocity sensitive imaging

AU - Ibrahim, Yaser M.

AU - Chwialkowski, Michael P.

AU - Pfeifer, Dennis P.

AU - Clarke, Geoffrey

AU - Kowal, Janice

AU - Wilbert, Glen

AU - Penshock, Ronald M.

PY - 1993

Y1 - 1993

N2 - Quantitative blood flow analysis is an important tool for the diagnosis of many diseases. Magnetic Resonance Imaging (MRI) offers a techniques for estimating pulsatile blood flow using phase difference of velocity-encoded and velocity-compensated image sequences. Here we present an automated system for quantitative analysis and visualization of blood flow and volume.

AB - Quantitative blood flow analysis is an important tool for the diagnosis of many diseases. Magnetic Resonance Imaging (MRI) offers a techniques for estimating pulsatile blood flow using phase difference of velocity-encoded and velocity-compensated image sequences. Here we present an automated system for quantitative analysis and visualization of blood flow and volume.

UR - http://www.scopus.com/inward/record.url?scp=0027867346&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027867346&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:0027867346

SN - 0780313771

VL - 15

SP - 170

EP - 171

BT - Proceedings of the Annual Conference on Engineering in Medicine and Biology

PB - Publ by IEEE

CY - Piscataway, NJ, United States

ER -