Cardiac output during exercise measured by acetylene rebreathing, thermodilution, and Fick techniques

C. C W Hsia, L. F. Herazo, M. Ramanathan, R. L. Johnson

Research output: Contribution to journalArticle

34 Citations (Scopus)

Abstract

In dogs during exercise, respiratory rate can reach 200 breaths/min, blood temperature can exceed 42°C, and hematocrit can approach 60%. To determine whether these changes significantly affect the measurement of cardiac output by the acetylene rebreathing method (Q̇c(RB)), we compared estimates of Q̇c(RB) with those measured by thermodilution and Fick (Q̇c(FI)) techniques in nine dogs at rest and during steady-state exercise on a treadmill up to near-maximal workloads. Solubility of acetylene in blood was corrected to the simultaneously measured blood temperature and hematocrit. Results were also adjusted for mixing efficiency. Up to a Q̇c(FI) of 20 1/min, Q̇c(RB) was not significantly different from Q̇c(FI) (P > 0.05). However, cardiac output measured by thermodilution was consistently higher than those measured by the other techniques (P < 0.0001). We conclude that the overall agreement between Q̇c(RB) and Q̇c(FI) estimates supports the validity of the rebreathing technique under exercise conditions where body temperature and hematocrit are changing rapidly and the breathing pattern is unrestrained. Systematic error by the thermodilution technique may be related to a variety of methodological issues as well as possible dissipation of cooling into the myocardial tissue and subsequent incomplete washout.

Original languageEnglish (US)
Pages (from-to)1612-1616
Number of pages5
JournalJournal of Applied Physiology
Volume78
Issue number4
StatePublished - 1995

Fingerprint

Thermodilution
Acetylene
Hematocrit
Cardiac Output
Dogs
Temperature
Respiratory Rate
Workload
Body Temperature
Solubility
Respiration

Keywords

  • acetylene
  • dog
  • hematocrit correction
  • mixing efficiency
  • pulmonary blood flow
  • temperature correction

ASJC Scopus subject areas

  • Endocrinology
  • Physiology
  • Orthopedics and Sports Medicine
  • Physical Therapy, Sports Therapy and Rehabilitation

Cite this

Cardiac output during exercise measured by acetylene rebreathing, thermodilution, and Fick techniques. / Hsia, C. C W; Herazo, L. F.; Ramanathan, M.; Johnson, R. L.

In: Journal of Applied Physiology, Vol. 78, No. 4, 1995, p. 1612-1616.

Research output: Contribution to journalArticle

Hsia, C. C W ; Herazo, L. F. ; Ramanathan, M. ; Johnson, R. L. / Cardiac output during exercise measured by acetylene rebreathing, thermodilution, and Fick techniques. In: Journal of Applied Physiology. 1995 ; Vol. 78, No. 4. pp. 1612-1616.
@article{483a32ac5c8e41f49c917aa4d1f7bbdb,
title = "Cardiac output during exercise measured by acetylene rebreathing, thermodilution, and Fick techniques",
abstract = "In dogs during exercise, respiratory rate can reach 200 breaths/min, blood temperature can exceed 42°C, and hematocrit can approach 60{\%}. To determine whether these changes significantly affect the measurement of cardiac output by the acetylene rebreathing method (Q̇c(RB)), we compared estimates of Q̇c(RB) with those measured by thermodilution and Fick (Q̇c(FI)) techniques in nine dogs at rest and during steady-state exercise on a treadmill up to near-maximal workloads. Solubility of acetylene in blood was corrected to the simultaneously measured blood temperature and hematocrit. Results were also adjusted for mixing efficiency. Up to a Q̇c(FI) of 20 1/min, Q̇c(RB) was not significantly different from Q̇c(FI) (P > 0.05). However, cardiac output measured by thermodilution was consistently higher than those measured by the other techniques (P < 0.0001). We conclude that the overall agreement between Q̇c(RB) and Q̇c(FI) estimates supports the validity of the rebreathing technique under exercise conditions where body temperature and hematocrit are changing rapidly and the breathing pattern is unrestrained. Systematic error by the thermodilution technique may be related to a variety of methodological issues as well as possible dissipation of cooling into the myocardial tissue and subsequent incomplete washout.",
keywords = "acetylene, dog, hematocrit correction, mixing efficiency, pulmonary blood flow, temperature correction",
author = "Hsia, {C. C W} and Herazo, {L. F.} and M. Ramanathan and Johnson, {R. L.}",
year = "1995",
language = "English (US)",
volume = "78",
pages = "1612--1616",
journal = "Journal of Applied Physiology",
issn = "0161-7567",
publisher = "American Physiological Society",
number = "4",

}

TY - JOUR

T1 - Cardiac output during exercise measured by acetylene rebreathing, thermodilution, and Fick techniques

AU - Hsia, C. C W

AU - Herazo, L. F.

AU - Ramanathan, M.

AU - Johnson, R. L.

PY - 1995

Y1 - 1995

N2 - In dogs during exercise, respiratory rate can reach 200 breaths/min, blood temperature can exceed 42°C, and hematocrit can approach 60%. To determine whether these changes significantly affect the measurement of cardiac output by the acetylene rebreathing method (Q̇c(RB)), we compared estimates of Q̇c(RB) with those measured by thermodilution and Fick (Q̇c(FI)) techniques in nine dogs at rest and during steady-state exercise on a treadmill up to near-maximal workloads. Solubility of acetylene in blood was corrected to the simultaneously measured blood temperature and hematocrit. Results were also adjusted for mixing efficiency. Up to a Q̇c(FI) of 20 1/min, Q̇c(RB) was not significantly different from Q̇c(FI) (P > 0.05). However, cardiac output measured by thermodilution was consistently higher than those measured by the other techniques (P < 0.0001). We conclude that the overall agreement between Q̇c(RB) and Q̇c(FI) estimates supports the validity of the rebreathing technique under exercise conditions where body temperature and hematocrit are changing rapidly and the breathing pattern is unrestrained. Systematic error by the thermodilution technique may be related to a variety of methodological issues as well as possible dissipation of cooling into the myocardial tissue and subsequent incomplete washout.

AB - In dogs during exercise, respiratory rate can reach 200 breaths/min, blood temperature can exceed 42°C, and hematocrit can approach 60%. To determine whether these changes significantly affect the measurement of cardiac output by the acetylene rebreathing method (Q̇c(RB)), we compared estimates of Q̇c(RB) with those measured by thermodilution and Fick (Q̇c(FI)) techniques in nine dogs at rest and during steady-state exercise on a treadmill up to near-maximal workloads. Solubility of acetylene in blood was corrected to the simultaneously measured blood temperature and hematocrit. Results were also adjusted for mixing efficiency. Up to a Q̇c(FI) of 20 1/min, Q̇c(RB) was not significantly different from Q̇c(FI) (P > 0.05). However, cardiac output measured by thermodilution was consistently higher than those measured by the other techniques (P < 0.0001). We conclude that the overall agreement between Q̇c(RB) and Q̇c(FI) estimates supports the validity of the rebreathing technique under exercise conditions where body temperature and hematocrit are changing rapidly and the breathing pattern is unrestrained. Systematic error by the thermodilution technique may be related to a variety of methodological issues as well as possible dissipation of cooling into the myocardial tissue and subsequent incomplete washout.

KW - acetylene

KW - dog

KW - hematocrit correction

KW - mixing efficiency

KW - pulmonary blood flow

KW - temperature correction

UR - http://www.scopus.com/inward/record.url?scp=0028914110&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028914110&partnerID=8YFLogxK

M3 - Article

C2 - 7615476

AN - SCOPUS:0028914110

VL - 78

SP - 1612

EP - 1616

JO - Journal of Applied Physiology

JF - Journal of Applied Physiology

SN - 0161-7567

IS - 4

ER -