Chronic monitoring of intracranial pressure using an in vivo calibrating sensor: Experience in patients with pseudotumor cerebri

P. R. Cooper, S. Moody, F. Sklar

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

A number of reliable methods are available for the short term monitoring of intracranial pressure (ICP). However, the danger of infection and the need for external connections make the use of these methods for extended periods inappropriate. Most previously described devices for chronic monitoring of ICP are of limited value because of uncertain drift from zero-point readings. The Hittman-Meyer ICP sensor approaches the ideal for a long term monitoring device. It is fully implantable and is accurate over a wide range of pressures and for extended periods. It is designed so that in vivo calibration may be performed in a noninvasive fashion. The authors report the use of this device in eight patients with pseudotumor cerebri. It has functioned accurately for periods ranging up to 14 months after implantation and has proven to be a valuable aid in the management of these patients.

Original languageEnglish (US)
Pages (from-to)666-670
Number of pages5
JournalNeurosurgery
Volume5
Issue number6
StatePublished - 1979

Fingerprint

Pseudotumor Cerebri
Intracranial Pressure
Equipment and Supplies
Calibration
Reading
Pressure
Infection

ASJC Scopus subject areas

  • Clinical Neurology
  • Surgery

Cite this

Chronic monitoring of intracranial pressure using an in vivo calibrating sensor : Experience in patients with pseudotumor cerebri. / Cooper, P. R.; Moody, S.; Sklar, F.

In: Neurosurgery, Vol. 5, No. 6, 1979, p. 666-670.

Research output: Contribution to journalArticle

@article{382c6ebe81f0479284dfcfa6de8db92b,
title = "Chronic monitoring of intracranial pressure using an in vivo calibrating sensor: Experience in patients with pseudotumor cerebri",
abstract = "A number of reliable methods are available for the short term monitoring of intracranial pressure (ICP). However, the danger of infection and the need for external connections make the use of these methods for extended periods inappropriate. Most previously described devices for chronic monitoring of ICP are of limited value because of uncertain drift from zero-point readings. The Hittman-Meyer ICP sensor approaches the ideal for a long term monitoring device. It is fully implantable and is accurate over a wide range of pressures and for extended periods. It is designed so that in vivo calibration may be performed in a noninvasive fashion. The authors report the use of this device in eight patients with pseudotumor cerebri. It has functioned accurately for periods ranging up to 14 months after implantation and has proven to be a valuable aid in the management of these patients.",
author = "Cooper, {P. R.} and S. Moody and F. Sklar",
year = "1979",
language = "English (US)",
volume = "5",
pages = "666--670",
journal = "Neurosurgery",
issn = "0148-396X",
publisher = "Lippincott Williams and Wilkins",
number = "6",

}

TY - JOUR

T1 - Chronic monitoring of intracranial pressure using an in vivo calibrating sensor

T2 - Experience in patients with pseudotumor cerebri

AU - Cooper, P. R.

AU - Moody, S.

AU - Sklar, F.

PY - 1979

Y1 - 1979

N2 - A number of reliable methods are available for the short term monitoring of intracranial pressure (ICP). However, the danger of infection and the need for external connections make the use of these methods for extended periods inappropriate. Most previously described devices for chronic monitoring of ICP are of limited value because of uncertain drift from zero-point readings. The Hittman-Meyer ICP sensor approaches the ideal for a long term monitoring device. It is fully implantable and is accurate over a wide range of pressures and for extended periods. It is designed so that in vivo calibration may be performed in a noninvasive fashion. The authors report the use of this device in eight patients with pseudotumor cerebri. It has functioned accurately for periods ranging up to 14 months after implantation and has proven to be a valuable aid in the management of these patients.

AB - A number of reliable methods are available for the short term monitoring of intracranial pressure (ICP). However, the danger of infection and the need for external connections make the use of these methods for extended periods inappropriate. Most previously described devices for chronic monitoring of ICP are of limited value because of uncertain drift from zero-point readings. The Hittman-Meyer ICP sensor approaches the ideal for a long term monitoring device. It is fully implantable and is accurate over a wide range of pressures and for extended periods. It is designed so that in vivo calibration may be performed in a noninvasive fashion. The authors report the use of this device in eight patients with pseudotumor cerebri. It has functioned accurately for periods ranging up to 14 months after implantation and has proven to be a valuable aid in the management of these patients.

UR - http://www.scopus.com/inward/record.url?scp=0018614021&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0018614021&partnerID=8YFLogxK

M3 - Article

C2 - 534074

AN - SCOPUS:0018614021

VL - 5

SP - 666

EP - 670

JO - Neurosurgery

JF - Neurosurgery

SN - 0148-396X

IS - 6

ER -