Comparison of pediatric end-tidal CO2 measured with nasal/oral cannula circuit and capillary Pco2

Thomas J. Abramo, Michael R. Cowan, Susan M. Scott, Patricia A. Primm, Robert A. Wiebe, Marla Signs

Research output: Contribution to journalArticle

21 Citations (Scopus)

Abstract

This study was designed to determine whether end-tidal carbon dioxide (ETCO2) values obtained by noninvasive oral/nasal cannula circuit with side-stream capnometry correlate reliably with capillary Pco2 (CapCO2) in a pediatric population without cardiopulmonary problems. Each patient was monitored until a reliable 5-minute ETCO2 waveform was obtained. A capillary blood gas sample was drawn while, simultaneously, ETCO2 was recorded. The difference between CapCO2 and ETCO2 levels was tested with a paired t-test at P < .001. The limits of agreement were established with a 95% confidence level. The stability of the measured difference across the range of mean scores (CapCO2 + ETCO2 2), age, and respiratory rate was tested using simple linear regression. Fifty-eight children (23 girls and 35 boys) had mean ETCO2 readings of 33.96 mm Hg (SD 4.26), and mean CapCO2 readings of 35.93 (SD 4.04). A relative average bias of 1.96 with ETCO2 lower than CapCO2 was established with 95% limits of agreement of ±5.2 mm Hg (t = 5.71). Variability of difference scores was not related to range of mean scores (r = .08), age (r = .09), or respiratory rate (r = .25). End-tidal CO2 measured by an oral/nasal cannula capnometry circuit is a noninvasive method of assessing indirect measurements of Pco2 in a normal pediatric population.

Original languageEnglish (US)
Pages (from-to)30-33
Number of pages4
JournalAmerican Journal of Emergency Medicine
Volume13
Issue number1
DOIs
StatePublished - 1995

Fingerprint

Pediatrics
Respiratory Rate
Reading
Carbon Dioxide
Population
Cannula
Linear Models
Gases

Keywords

  • capillary Pco
  • capnometry
  • End-tidal carbon dioxide
  • oral/nasal cannula

ASJC Scopus subject areas

  • Emergency Medicine

Cite this

Comparison of pediatric end-tidal CO2 measured with nasal/oral cannula circuit and capillary Pco2 . / Abramo, Thomas J.; Cowan, Michael R.; Scott, Susan M.; Primm, Patricia A.; Wiebe, Robert A.; Signs, Marla.

In: American Journal of Emergency Medicine, Vol. 13, No. 1, 1995, p. 30-33.

Research output: Contribution to journalArticle

Abramo, Thomas J. ; Cowan, Michael R. ; Scott, Susan M. ; Primm, Patricia A. ; Wiebe, Robert A. ; Signs, Marla. / Comparison of pediatric end-tidal CO2 measured with nasal/oral cannula circuit and capillary Pco2 In: American Journal of Emergency Medicine. 1995 ; Vol. 13, No. 1. pp. 30-33.
@article{0b15f261f1dd41d7a2bd4eece01ef585,
title = "Comparison of pediatric end-tidal CO2 measured with nasal/oral cannula circuit and capillary Pco2",
abstract = "This study was designed to determine whether end-tidal carbon dioxide (ETCO2) values obtained by noninvasive oral/nasal cannula circuit with side-stream capnometry correlate reliably with capillary Pco2 (CapCO2) in a pediatric population without cardiopulmonary problems. Each patient was monitored until a reliable 5-minute ETCO2 waveform was obtained. A capillary blood gas sample was drawn while, simultaneously, ETCO2 was recorded. The difference between CapCO2 and ETCO2 levels was tested with a paired t-test at P < .001. The limits of agreement were established with a 95{\%} confidence level. The stability of the measured difference across the range of mean scores (CapCO2 + ETCO2 2), age, and respiratory rate was tested using simple linear regression. Fifty-eight children (23 girls and 35 boys) had mean ETCO2 readings of 33.96 mm Hg (SD 4.26), and mean CapCO2 readings of 35.93 (SD 4.04). A relative average bias of 1.96 with ETCO2 lower than CapCO2 was established with 95{\%} limits of agreement of ±5.2 mm Hg (t = 5.71). Variability of difference scores was not related to range of mean scores (r = .08), age (r = .09), or respiratory rate (r = .25). End-tidal CO2 measured by an oral/nasal cannula capnometry circuit is a noninvasive method of assessing indirect measurements of Pco2 in a normal pediatric population.",
keywords = "capillary Pco, capnometry, End-tidal carbon dioxide, oral/nasal cannula",
author = "Abramo, {Thomas J.} and Cowan, {Michael R.} and Scott, {Susan M.} and Primm, {Patricia A.} and Wiebe, {Robert A.} and Marla Signs",
year = "1995",
doi = "10.1016/0735-6757(95)90236-8",
language = "English (US)",
volume = "13",
pages = "30--33",
journal = "American Journal of Emergency Medicine",
issn = "0735-6757",
publisher = "W.B. Saunders Ltd",
number = "1",

}

TY - JOUR

T1 - Comparison of pediatric end-tidal CO2 measured with nasal/oral cannula circuit and capillary Pco2

AU - Abramo, Thomas J.

AU - Cowan, Michael R.

AU - Scott, Susan M.

AU - Primm, Patricia A.

AU - Wiebe, Robert A.

AU - Signs, Marla

PY - 1995

Y1 - 1995

N2 - This study was designed to determine whether end-tidal carbon dioxide (ETCO2) values obtained by noninvasive oral/nasal cannula circuit with side-stream capnometry correlate reliably with capillary Pco2 (CapCO2) in a pediatric population without cardiopulmonary problems. Each patient was monitored until a reliable 5-minute ETCO2 waveform was obtained. A capillary blood gas sample was drawn while, simultaneously, ETCO2 was recorded. The difference between CapCO2 and ETCO2 levels was tested with a paired t-test at P < .001. The limits of agreement were established with a 95% confidence level. The stability of the measured difference across the range of mean scores (CapCO2 + ETCO2 2), age, and respiratory rate was tested using simple linear regression. Fifty-eight children (23 girls and 35 boys) had mean ETCO2 readings of 33.96 mm Hg (SD 4.26), and mean CapCO2 readings of 35.93 (SD 4.04). A relative average bias of 1.96 with ETCO2 lower than CapCO2 was established with 95% limits of agreement of ±5.2 mm Hg (t = 5.71). Variability of difference scores was not related to range of mean scores (r = .08), age (r = .09), or respiratory rate (r = .25). End-tidal CO2 measured by an oral/nasal cannula capnometry circuit is a noninvasive method of assessing indirect measurements of Pco2 in a normal pediatric population.

AB - This study was designed to determine whether end-tidal carbon dioxide (ETCO2) values obtained by noninvasive oral/nasal cannula circuit with side-stream capnometry correlate reliably with capillary Pco2 (CapCO2) in a pediatric population without cardiopulmonary problems. Each patient was monitored until a reliable 5-minute ETCO2 waveform was obtained. A capillary blood gas sample was drawn while, simultaneously, ETCO2 was recorded. The difference between CapCO2 and ETCO2 levels was tested with a paired t-test at P < .001. The limits of agreement were established with a 95% confidence level. The stability of the measured difference across the range of mean scores (CapCO2 + ETCO2 2), age, and respiratory rate was tested using simple linear regression. Fifty-eight children (23 girls and 35 boys) had mean ETCO2 readings of 33.96 mm Hg (SD 4.26), and mean CapCO2 readings of 35.93 (SD 4.04). A relative average bias of 1.96 with ETCO2 lower than CapCO2 was established with 95% limits of agreement of ±5.2 mm Hg (t = 5.71). Variability of difference scores was not related to range of mean scores (r = .08), age (r = .09), or respiratory rate (r = .25). End-tidal CO2 measured by an oral/nasal cannula capnometry circuit is a noninvasive method of assessing indirect measurements of Pco2 in a normal pediatric population.

KW - capillary Pco

KW - capnometry

KW - End-tidal carbon dioxide

KW - oral/nasal cannula

UR - http://www.scopus.com/inward/record.url?scp=0028801869&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028801869&partnerID=8YFLogxK

U2 - 10.1016/0735-6757(95)90236-8

DO - 10.1016/0735-6757(95)90236-8

M3 - Article

C2 - 7832949

AN - SCOPUS:0028801869

VL - 13

SP - 30

EP - 33

JO - American Journal of Emergency Medicine

JF - American Journal of Emergency Medicine

SN - 0735-6757

IS - 1

ER -