Continuous noninvasive monitoring of cardiac performance and tissue perfusion in pediatric trauma patients

Matthew Martin, Carlos Brown, David Bayard, Demetrios Demetriades, Ali Salim, Ryan Gertz, Kenneth Azarow, Charles C J Wo, William Shoemaker

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Purpose: The aim of this study was to assess the accuracy of a continuous survival probability prediction using noninvasive measures of cardiac performance and tissue perfusion in severely injured pediatric patients. Methods: Review of all patients entered into a prospective noninvasive monitoring protocol. Cardiac index (CI) was measured using a thoracic bioimpedance device and tissue perfusion was assessed by transcutaneous carbon dioxide (Ptcco2) tension and oxygen tension indexed to the fraction of inspired oxygen (Ptco2/Fio2). Survival probability (SP) was continuously calculated using a stochastic analysis program. Results: There were 45 patients with a total of 953 data sets. The mean age was 11 years (range, 1-16 years) with a mean Injury Severity Score of 24 (±16). There was no difference between survivors (n = 32) and nonsurvivors (n = 13) at study entry for heart rate, blood pressure, CI, or pulse oximetry (all P > .05). However, survivors demonstrated higher Ptcco2 (45 vs 35), higher Ptco2/Fio2 (236 vs 156), and higher predicted SP (89% vs 62%) compared with nonsurvivors at study entry and throughout the monitoring period (all P < .01). For the entire data set, the strongest independent predictors of survival were Ptco2/Fio2 and SP. The area under the receiver operating characteristic curve for mortality prediction was 0.83 for SP and 0.71 for Ptco2/Fio2, compared with 0.6 for heart rate, 0.51 for blood pressure, and 0.53 for CI. Similar hemodynamic patterns were observed for all injury patterns with the exception of those with severe brain injury. Conclusions: Thoracic bioimpedance and transcutaneous monitoring give critical real-time hemodynamic and tissue perfusion data that can provide early identification of pathologic flow patterns and accurately predict survival.

Original languageEnglish (US)
Pages (from-to)1957-1963
Number of pages7
JournalJournal of Pediatric Surgery
Volume40
Issue number12
DOIs
StatePublished - Dec 2005

Fingerprint

Transcutaneous Blood Gas Monitoring
Perfusion
Pediatrics
Survival
Wounds and Injuries
Survivors
Thorax
Heart Rate
Hemodynamics
Oxygen
Blood Pressure
Injury Severity Score
Oximetry
Carbon Dioxide
ROC Curve
Brain Injuries
Equipment and Supplies
Mortality

Keywords

  • Noninvasive monitoring
  • Survival prediction
  • Thoracic bioimpedance
  • Transcutaneous oxygen
  • Trauma

ASJC Scopus subject areas

  • Surgery

Cite this

Martin, M., Brown, C., Bayard, D., Demetriades, D., Salim, A., Gertz, R., ... Shoemaker, W. (2005). Continuous noninvasive monitoring of cardiac performance and tissue perfusion in pediatric trauma patients. Journal of Pediatric Surgery, 40(12), 1957-1963. https://doi.org/10.1016/j.jpedsurg.2005.08.017

Continuous noninvasive monitoring of cardiac performance and tissue perfusion in pediatric trauma patients. / Martin, Matthew; Brown, Carlos; Bayard, David; Demetriades, Demetrios; Salim, Ali; Gertz, Ryan; Azarow, Kenneth; Wo, Charles C J; Shoemaker, William.

In: Journal of Pediatric Surgery, Vol. 40, No. 12, 12.2005, p. 1957-1963.

Research output: Contribution to journalArticle

Martin, M, Brown, C, Bayard, D, Demetriades, D, Salim, A, Gertz, R, Azarow, K, Wo, CCJ & Shoemaker, W 2005, 'Continuous noninvasive monitoring of cardiac performance and tissue perfusion in pediatric trauma patients', Journal of Pediatric Surgery, vol. 40, no. 12, pp. 1957-1963. https://doi.org/10.1016/j.jpedsurg.2005.08.017
Martin, Matthew ; Brown, Carlos ; Bayard, David ; Demetriades, Demetrios ; Salim, Ali ; Gertz, Ryan ; Azarow, Kenneth ; Wo, Charles C J ; Shoemaker, William. / Continuous noninvasive monitoring of cardiac performance and tissue perfusion in pediatric trauma patients. In: Journal of Pediatric Surgery. 2005 ; Vol. 40, No. 12. pp. 1957-1963.
@article{aeae422733df4a05a6d1fc1edb226c16,
title = "Continuous noninvasive monitoring of cardiac performance and tissue perfusion in pediatric trauma patients",
abstract = "Purpose: The aim of this study was to assess the accuracy of a continuous survival probability prediction using noninvasive measures of cardiac performance and tissue perfusion in severely injured pediatric patients. Methods: Review of all patients entered into a prospective noninvasive monitoring protocol. Cardiac index (CI) was measured using a thoracic bioimpedance device and tissue perfusion was assessed by transcutaneous carbon dioxide (Ptcco2) tension and oxygen tension indexed to the fraction of inspired oxygen (Ptco2/Fio2). Survival probability (SP) was continuously calculated using a stochastic analysis program. Results: There were 45 patients with a total of 953 data sets. The mean age was 11 years (range, 1-16 years) with a mean Injury Severity Score of 24 (±16). There was no difference between survivors (n = 32) and nonsurvivors (n = 13) at study entry for heart rate, blood pressure, CI, or pulse oximetry (all P > .05). However, survivors demonstrated higher Ptcco2 (45 vs 35), higher Ptco2/Fio2 (236 vs 156), and higher predicted SP (89{\%} vs 62{\%}) compared with nonsurvivors at study entry and throughout the monitoring period (all P < .01). For the entire data set, the strongest independent predictors of survival were Ptco2/Fio2 and SP. The area under the receiver operating characteristic curve for mortality prediction was 0.83 for SP and 0.71 for Ptco2/Fio2, compared with 0.6 for heart rate, 0.51 for blood pressure, and 0.53 for CI. Similar hemodynamic patterns were observed for all injury patterns with the exception of those with severe brain injury. Conclusions: Thoracic bioimpedance and transcutaneous monitoring give critical real-time hemodynamic and tissue perfusion data that can provide early identification of pathologic flow patterns and accurately predict survival.",
keywords = "Noninvasive monitoring, Survival prediction, Thoracic bioimpedance, Transcutaneous oxygen, Trauma",
author = "Matthew Martin and Carlos Brown and David Bayard and Demetrios Demetriades and Ali Salim and Ryan Gertz and Kenneth Azarow and Wo, {Charles C J} and William Shoemaker",
year = "2005",
month = "12",
doi = "10.1016/j.jpedsurg.2005.08.017",
language = "English (US)",
volume = "40",
pages = "1957--1963",
journal = "Journal of Pediatric Surgery",
issn = "0022-3468",
publisher = "W.B. Saunders Ltd",
number = "12",

}

TY - JOUR

T1 - Continuous noninvasive monitoring of cardiac performance and tissue perfusion in pediatric trauma patients

AU - Martin, Matthew

AU - Brown, Carlos

AU - Bayard, David

AU - Demetriades, Demetrios

AU - Salim, Ali

AU - Gertz, Ryan

AU - Azarow, Kenneth

AU - Wo, Charles C J

AU - Shoemaker, William

PY - 2005/12

Y1 - 2005/12

N2 - Purpose: The aim of this study was to assess the accuracy of a continuous survival probability prediction using noninvasive measures of cardiac performance and tissue perfusion in severely injured pediatric patients. Methods: Review of all patients entered into a prospective noninvasive monitoring protocol. Cardiac index (CI) was measured using a thoracic bioimpedance device and tissue perfusion was assessed by transcutaneous carbon dioxide (Ptcco2) tension and oxygen tension indexed to the fraction of inspired oxygen (Ptco2/Fio2). Survival probability (SP) was continuously calculated using a stochastic analysis program. Results: There were 45 patients with a total of 953 data sets. The mean age was 11 years (range, 1-16 years) with a mean Injury Severity Score of 24 (±16). There was no difference between survivors (n = 32) and nonsurvivors (n = 13) at study entry for heart rate, blood pressure, CI, or pulse oximetry (all P > .05). However, survivors demonstrated higher Ptcco2 (45 vs 35), higher Ptco2/Fio2 (236 vs 156), and higher predicted SP (89% vs 62%) compared with nonsurvivors at study entry and throughout the monitoring period (all P < .01). For the entire data set, the strongest independent predictors of survival were Ptco2/Fio2 and SP. The area under the receiver operating characteristic curve for mortality prediction was 0.83 for SP and 0.71 for Ptco2/Fio2, compared with 0.6 for heart rate, 0.51 for blood pressure, and 0.53 for CI. Similar hemodynamic patterns were observed for all injury patterns with the exception of those with severe brain injury. Conclusions: Thoracic bioimpedance and transcutaneous monitoring give critical real-time hemodynamic and tissue perfusion data that can provide early identification of pathologic flow patterns and accurately predict survival.

AB - Purpose: The aim of this study was to assess the accuracy of a continuous survival probability prediction using noninvasive measures of cardiac performance and tissue perfusion in severely injured pediatric patients. Methods: Review of all patients entered into a prospective noninvasive monitoring protocol. Cardiac index (CI) was measured using a thoracic bioimpedance device and tissue perfusion was assessed by transcutaneous carbon dioxide (Ptcco2) tension and oxygen tension indexed to the fraction of inspired oxygen (Ptco2/Fio2). Survival probability (SP) was continuously calculated using a stochastic analysis program. Results: There were 45 patients with a total of 953 data sets. The mean age was 11 years (range, 1-16 years) with a mean Injury Severity Score of 24 (±16). There was no difference between survivors (n = 32) and nonsurvivors (n = 13) at study entry for heart rate, blood pressure, CI, or pulse oximetry (all P > .05). However, survivors demonstrated higher Ptcco2 (45 vs 35), higher Ptco2/Fio2 (236 vs 156), and higher predicted SP (89% vs 62%) compared with nonsurvivors at study entry and throughout the monitoring period (all P < .01). For the entire data set, the strongest independent predictors of survival were Ptco2/Fio2 and SP. The area under the receiver operating characteristic curve for mortality prediction was 0.83 for SP and 0.71 for Ptco2/Fio2, compared with 0.6 for heart rate, 0.51 for blood pressure, and 0.53 for CI. Similar hemodynamic patterns were observed for all injury patterns with the exception of those with severe brain injury. Conclusions: Thoracic bioimpedance and transcutaneous monitoring give critical real-time hemodynamic and tissue perfusion data that can provide early identification of pathologic flow patterns and accurately predict survival.

KW - Noninvasive monitoring

KW - Survival prediction

KW - Thoracic bioimpedance

KW - Transcutaneous oxygen

KW - Trauma

UR - http://www.scopus.com/inward/record.url?scp=28844432063&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=28844432063&partnerID=8YFLogxK

U2 - 10.1016/j.jpedsurg.2005.08.017

DO - 10.1016/j.jpedsurg.2005.08.017

M3 - Article

VL - 40

SP - 1957

EP - 1963

JO - Journal of Pediatric Surgery

JF - Journal of Pediatric Surgery

SN - 0022-3468

IS - 12

ER -