Derivation of system matrix from simulation data for an animal SPECT with slit-slat collimator

Rutao Yao, Tianyu Ma, Yiping Shao

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

We developed SPECT imaging capability on an animal PET system. Our goal was to provide animal PET users the SPECT capability at a low cost and facilitate potential PET/SPECT dual modality imaging applications. The SPECT function was enabled with a slit-slat collimator insert and by acquiring data in singles mode. The focus of this paper is to establish a method for deriving the system matrix for the SPECT system from Monte Carlo simulation. With the Monte Carlo package GATE, we simulated a uniform cylinder source which filled the SPECT field of view (FOV). To reduce the size of the original large and sparse system matrix, the detectors that were exposed to individual emission elements were selectively included for system matrix derivation and storage. The axial symmetry of the system was exploited so that only the base-axial volume was used for deriving system response. The system matrix derived was validated with point source measurements at known positions and implemented in an iterative reconstruction algorithm. The imaging performance of the system matrix was evaluated with experimental phantom studies. Reconstructed phantom images were artifact free and demonstrated expected spatial resolution. The method presented in this work is generally applicable to other SPECT imaging systems.

Original languageEnglish (US)
Article number5280497
Pages (from-to)2651-2658
Number of pages8
JournalIEEE Transactions on Nuclear Science
Volume56
Issue number5
DOIs
StatePublished - Oct 1 2009

Fingerprint

data simulation
collimators
slits
animals
Animals
derivation
matrices
Imaging techniques
GARP Atlantic Tropical Experiment
inserts
Imaging systems
point sources
field of view
artifacts
spatial resolution
Detectors
detectors
symmetry
Costs
simulation

Keywords

  • Image reconstruction
  • Monte Carlo simulation
  • PET/SPECT dual tracer imaging
  • SPECT
  • System matrix

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Nuclear Energy and Engineering
  • Nuclear and High Energy Physics

Cite this

Derivation of system matrix from simulation data for an animal SPECT with slit-slat collimator. / Yao, Rutao; Ma, Tianyu; Shao, Yiping.

In: IEEE Transactions on Nuclear Science, Vol. 56, No. 5, 5280497, 01.10.2009, p. 2651-2658.

Research output: Contribution to journalArticle

@article{11956a0caf264f039ce39286625cc6e8,
title = "Derivation of system matrix from simulation data for an animal SPECT with slit-slat collimator",
abstract = "We developed SPECT imaging capability on an animal PET system. Our goal was to provide animal PET users the SPECT capability at a low cost and facilitate potential PET/SPECT dual modality imaging applications. The SPECT function was enabled with a slit-slat collimator insert and by acquiring data in singles mode. The focus of this paper is to establish a method for deriving the system matrix for the SPECT system from Monte Carlo simulation. With the Monte Carlo package GATE, we simulated a uniform cylinder source which filled the SPECT field of view (FOV). To reduce the size of the original large and sparse system matrix, the detectors that were exposed to individual emission elements were selectively included for system matrix derivation and storage. The axial symmetry of the system was exploited so that only the base-axial volume was used for deriving system response. The system matrix derived was validated with point source measurements at known positions and implemented in an iterative reconstruction algorithm. The imaging performance of the system matrix was evaluated with experimental phantom studies. Reconstructed phantom images were artifact free and demonstrated expected spatial resolution. The method presented in this work is generally applicable to other SPECT imaging systems.",
keywords = "Image reconstruction, Monte Carlo simulation, PET/SPECT dual tracer imaging, SPECT, System matrix",
author = "Rutao Yao and Tianyu Ma and Yiping Shao",
year = "2009",
month = "10",
day = "1",
doi = "10.1109/TNS.2009.2022940",
language = "English (US)",
volume = "56",
pages = "2651--2658",
journal = "IEEE Transactions on Nuclear Science",
issn = "0018-9499",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "5",

}

TY - JOUR

T1 - Derivation of system matrix from simulation data for an animal SPECT with slit-slat collimator

AU - Yao, Rutao

AU - Ma, Tianyu

AU - Shao, Yiping

PY - 2009/10/1

Y1 - 2009/10/1

N2 - We developed SPECT imaging capability on an animal PET system. Our goal was to provide animal PET users the SPECT capability at a low cost and facilitate potential PET/SPECT dual modality imaging applications. The SPECT function was enabled with a slit-slat collimator insert and by acquiring data in singles mode. The focus of this paper is to establish a method for deriving the system matrix for the SPECT system from Monte Carlo simulation. With the Monte Carlo package GATE, we simulated a uniform cylinder source which filled the SPECT field of view (FOV). To reduce the size of the original large and sparse system matrix, the detectors that were exposed to individual emission elements were selectively included for system matrix derivation and storage. The axial symmetry of the system was exploited so that only the base-axial volume was used for deriving system response. The system matrix derived was validated with point source measurements at known positions and implemented in an iterative reconstruction algorithm. The imaging performance of the system matrix was evaluated with experimental phantom studies. Reconstructed phantom images were artifact free and demonstrated expected spatial resolution. The method presented in this work is generally applicable to other SPECT imaging systems.

AB - We developed SPECT imaging capability on an animal PET system. Our goal was to provide animal PET users the SPECT capability at a low cost and facilitate potential PET/SPECT dual modality imaging applications. The SPECT function was enabled with a slit-slat collimator insert and by acquiring data in singles mode. The focus of this paper is to establish a method for deriving the system matrix for the SPECT system from Monte Carlo simulation. With the Monte Carlo package GATE, we simulated a uniform cylinder source which filled the SPECT field of view (FOV). To reduce the size of the original large and sparse system matrix, the detectors that were exposed to individual emission elements were selectively included for system matrix derivation and storage. The axial symmetry of the system was exploited so that only the base-axial volume was used for deriving system response. The system matrix derived was validated with point source measurements at known positions and implemented in an iterative reconstruction algorithm. The imaging performance of the system matrix was evaluated with experimental phantom studies. Reconstructed phantom images were artifact free and demonstrated expected spatial resolution. The method presented in this work is generally applicable to other SPECT imaging systems.

KW - Image reconstruction

KW - Monte Carlo simulation

KW - PET/SPECT dual tracer imaging

KW - SPECT

KW - System matrix

UR - http://www.scopus.com/inward/record.url?scp=70350562115&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70350562115&partnerID=8YFLogxK

U2 - 10.1109/TNS.2009.2022940

DO - 10.1109/TNS.2009.2022940

M3 - Article

AN - SCOPUS:70350562115

VL - 56

SP - 2651

EP - 2658

JO - IEEE Transactions on Nuclear Science

JF - IEEE Transactions on Nuclear Science

SN - 0018-9499

IS - 5

M1 - 5280497

ER -