Device closure of an atrial septal defect following successful balloon valvuloplasty in a neonate with critical pulmonary valve stenosis and persistent cyanosis

A. W. Nugent, S. Menahem, T. H. Goh, W. Butt

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Persistent cyanosis after successful balloon valvuloplasty for neonatal critical pulmonary valve stenosis is often related to poor right ventricular compliance and right-to-left shunting at the atrial level. A successful catheter closure of an atrial septal defect was performed with a dramatic increase in systemic oxygen saturation alleviating the need for a surgical systemic-to-pulmonary artery shunt.

Original languageEnglish (US)
Pages (from-to)170-171
Number of pages2
JournalPediatric Cardiology
Volume21
Issue number2
DOIs
StatePublished - Mar 2000

Fingerprint

Balloon Valvuloplasty
Cyanosis
Pulmonary Valve Stenosis
Atrial Heart Septal Defects
Pulmonary Artery
Compliance
Catheters
Oxygen
Equipment and Supplies

Keywords

  • ASD closure
  • Critical pulmonary valve stenosis
  • Neonate

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Pediatrics, Perinatology, and Child Health

Cite this

Device closure of an atrial septal defect following successful balloon valvuloplasty in a neonate with critical pulmonary valve stenosis and persistent cyanosis. / Nugent, A. W.; Menahem, S.; Goh, T. H.; Butt, W.

In: Pediatric Cardiology, Vol. 21, No. 2, 03.2000, p. 170-171.

Research output: Contribution to journalArticle

@article{b60f4411588f498a9beba5f71cebaa29,
title = "Device closure of an atrial septal defect following successful balloon valvuloplasty in a neonate with critical pulmonary valve stenosis and persistent cyanosis",
abstract = "Persistent cyanosis after successful balloon valvuloplasty for neonatal critical pulmonary valve stenosis is often related to poor right ventricular compliance and right-to-left shunting at the atrial level. A successful catheter closure of an atrial septal defect was performed with a dramatic increase in systemic oxygen saturation alleviating the need for a surgical systemic-to-pulmonary artery shunt.",
keywords = "ASD closure, Critical pulmonary valve stenosis, Neonate",
author = "Nugent, {A. W.} and S. Menahem and Goh, {T. H.} and W. Butt",
year = "2000",
month = "3",
doi = "10.1007/s002469910030",
language = "English (US)",
volume = "21",
pages = "170--171",
journal = "Pediatric Cardiology",
issn = "0172-0643",
publisher = "Springer New York",
number = "2",

}

TY - JOUR

T1 - Device closure of an atrial septal defect following successful balloon valvuloplasty in a neonate with critical pulmonary valve stenosis and persistent cyanosis

AU - Nugent, A. W.

AU - Menahem, S.

AU - Goh, T. H.

AU - Butt, W.

PY - 2000/3

Y1 - 2000/3

N2 - Persistent cyanosis after successful balloon valvuloplasty for neonatal critical pulmonary valve stenosis is often related to poor right ventricular compliance and right-to-left shunting at the atrial level. A successful catheter closure of an atrial septal defect was performed with a dramatic increase in systemic oxygen saturation alleviating the need for a surgical systemic-to-pulmonary artery shunt.

AB - Persistent cyanosis after successful balloon valvuloplasty for neonatal critical pulmonary valve stenosis is often related to poor right ventricular compliance and right-to-left shunting at the atrial level. A successful catheter closure of an atrial septal defect was performed with a dramatic increase in systemic oxygen saturation alleviating the need for a surgical systemic-to-pulmonary artery shunt.

KW - ASD closure

KW - Critical pulmonary valve stenosis

KW - Neonate

UR - http://www.scopus.com/inward/record.url?scp=0034096697&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034096697&partnerID=8YFLogxK

U2 - 10.1007/s002469910030

DO - 10.1007/s002469910030

M3 - Article

C2 - 10754092

AN - SCOPUS:0034096697

VL - 21

SP - 170

EP - 171

JO - Pediatric Cardiology

JF - Pediatric Cardiology

SN - 0172-0643

IS - 2

ER -