Dosimetric comparison of rectal-sparing capabilities of rectal balloon vs injectable spacer gel in stereotactic body radiation therapy for prostate cancer: lessons learned from prospective trials

Ryan T. Jones, Nima Hassan Rezaeian, Neil B Desai, Yair Lotan, Xun Jia, Raquibul Hannan, D. W.Nathan Kim, Brad Hornberger, Jeffrey Dubas, Aaron M Laine, Michael J. Zelefsky, Robert Timmerman, Michael R Folkert

Research output: Contribution to journalArticlepeer-review

23 Scopus citations

Abstract

This study aimed to compare the rectal-sparing capabilities of rectal balloons vs absorbable injectable spacer gel in stereotactic body radiation therapy (SBRT) for prostate cancer. Patient samples included in this analysis were obtained from 2 multi-institutional prospective trials of SBRT for prostate cancer using a rectal balloon (n = 36 patients) and injectable spacer gel (n = 36). Treatment prescription dose was 45 Gy in 5 fractions in 42 patients; for equal comparison, the remaining 30 patients were rescaled to 45 Gy from 47.5 Gy prescription (n = 6) and 50 Gy prescription (n = 24). The median prostate volumes and body mass index in the 2 patient samples were not statistically significantly different (p = 0.67 and 0.45, respectively), supporting anatomic similarity between cohorts. The injectable spacer gel achieved dosimetric superiority over the rectal balloon with respect to the maximum dose to the rectum (42.3 vs 46.2 Gy, p < 0.001), dose delivered to 33% of the rectal circumference (28 vs 35.1 Gy, p < 0.001), and absolute volume of rectum receiving 45 Gy (V45Gy), V40Gy, and V30Gy (0.3 vs 1.7 cc, 1 vs 5.4 cc, and 4.1 vs 9.6 cc, respectively; p < 0.001 in all cases). There was no difference between the 2 groups with respect to the V50Gy of the rectum or the dose to 50% of the rectal circumference (p = 0.29 and 0.06, respectively). The V18.3Gy of the bladder was significantly larger with the rectal balloon (19.9 vs 14.5 cc, p = 0.003). In this analysis of patients enrolled on 2 consecutive multi-institutional prospective trials of SBRT for prostate cancer, the injectable spacer gel outperformed the rectal balloon in the majority of the examined and relevant dosimetric rectal-sparing parameters. The rectal balloon did not outperform the injectable spacer gel in any measured rectal dose parameter.

Original languageEnglish (US)
Pages (from-to)341-347
Number of pages7
JournalMedical Dosimetry
Volume42
Issue number4
DOIs
StatePublished - Feb 4 2017

Keywords

  • Rectal balloon
  • Rectal dosimetry
  • Rectal spacer
  • Rectal toxicity
  • Stereotactic body radiation therapy

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Oncology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Dosimetric comparison of rectal-sparing capabilities of rectal balloon vs injectable spacer gel in stereotactic body radiation therapy for prostate cancer: lessons learned from prospective trials'. Together they form a unique fingerprint.

Cite this