Durability of Hearing Preservation after Cochlear Implantation with Conventional-Length Electrodes and Scala Tympani Insertion

Alex D. Sweeney, Jacob B. Hunter, Matthew L. Carlson, Alejandro Rivas, Marc L. Bennett, Rene H. Gifford, Jack H. Noble, David S. Haynes, Robert F. Labadie, George B. Wanna

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Objectives To analyze factors that influence hearing preservation over time in cochlear implant recipients with conventional-length electrode arrays located entirely within the scala tympani. Study Design Case series with planned chart review. Setting Single tertiary academic referral center. Subjects and Methods A retrospective review was performed to analyze a subgroup of cochlear implant recipients with residual acoustic hearing. Patients were included in the study only if their electrode arrays remained fully in the scala tympani after insertion and serviceable acoustic hearing (≤80 dB at 250 Hz) was preserved. Electrode array location was verified through a validated radiographic assessment tool. Patients with <6 months of audiologic follow-up were excluded. The main outcome measure was change in acoustic hearing thresholds from implant activation to the last available follow-up. Results A total of 16 cases met inclusion criteria (median age, 70.6 years; range, 29.4-82.2; 50% female). The average follow-up was 18.0 months (median, 16.1; range, 6.2-36.4). Patients with a lateral wall electrode array were more likely to have stable acoustic thresholds over time (P <.05). Positive correlations were seen between continued hearing loss following activation and larger initial postoperative acoustic threshold shifts, though statistical significance was not achieved. Age, sex, and noise exposure had no significant influence on continued hearing preservation over time. Conclusions To control for hearing loss associated with interscalar excursion during cochlear implantation, the present study evaluated patients only with conventional electrode arrays located entirely within the scala tympani. In this group, the style of electrode array may influence residual hearing preservation over time.

Original languageEnglish (US)
Pages (from-to)907-913
Number of pages7
JournalOtolaryngology - Head and Neck Surgery (United States)
Volume154
Issue number5
DOIs
StatePublished - Jan 1 2016

Fingerprint

Scala Tympani
Cochlear Implantation
Hearing
Electrodes
Acoustics
Cochlear Implants
Hearing Loss
Tertiary Care Centers
Statistical Factor Analysis
Noise
Outcome Assessment (Health Care)

Keywords

  • cochlear implantation
  • cochlear trauma
  • hearing preservation
  • image guidance

ASJC Scopus subject areas

  • Surgery
  • Otorhinolaryngology

Cite this

Durability of Hearing Preservation after Cochlear Implantation with Conventional-Length Electrodes and Scala Tympani Insertion. / Sweeney, Alex D.; Hunter, Jacob B.; Carlson, Matthew L.; Rivas, Alejandro; Bennett, Marc L.; Gifford, Rene H.; Noble, Jack H.; Haynes, David S.; Labadie, Robert F.; Wanna, George B.

In: Otolaryngology - Head and Neck Surgery (United States), Vol. 154, No. 5, 01.01.2016, p. 907-913.

Research output: Contribution to journalArticle

Sweeney, Alex D. ; Hunter, Jacob B. ; Carlson, Matthew L. ; Rivas, Alejandro ; Bennett, Marc L. ; Gifford, Rene H. ; Noble, Jack H. ; Haynes, David S. ; Labadie, Robert F. ; Wanna, George B. / Durability of Hearing Preservation after Cochlear Implantation with Conventional-Length Electrodes and Scala Tympani Insertion. In: Otolaryngology - Head and Neck Surgery (United States). 2016 ; Vol. 154, No. 5. pp. 907-913.
@article{bb34aef65f0a4a8abbdca58c00bfdf7f,
title = "Durability of Hearing Preservation after Cochlear Implantation with Conventional-Length Electrodes and Scala Tympani Insertion",
abstract = "Objectives To analyze factors that influence hearing preservation over time in cochlear implant recipients with conventional-length electrode arrays located entirely within the scala tympani. Study Design Case series with planned chart review. Setting Single tertiary academic referral center. Subjects and Methods A retrospective review was performed to analyze a subgroup of cochlear implant recipients with residual acoustic hearing. Patients were included in the study only if their electrode arrays remained fully in the scala tympani after insertion and serviceable acoustic hearing (≤80 dB at 250 Hz) was preserved. Electrode array location was verified through a validated radiographic assessment tool. Patients with <6 months of audiologic follow-up were excluded. The main outcome measure was change in acoustic hearing thresholds from implant activation to the last available follow-up. Results A total of 16 cases met inclusion criteria (median age, 70.6 years; range, 29.4-82.2; 50{\%} female). The average follow-up was 18.0 months (median, 16.1; range, 6.2-36.4). Patients with a lateral wall electrode array were more likely to have stable acoustic thresholds over time (P <.05). Positive correlations were seen between continued hearing loss following activation and larger initial postoperative acoustic threshold shifts, though statistical significance was not achieved. Age, sex, and noise exposure had no significant influence on continued hearing preservation over time. Conclusions To control for hearing loss associated with interscalar excursion during cochlear implantation, the present study evaluated patients only with conventional electrode arrays located entirely within the scala tympani. In this group, the style of electrode array may influence residual hearing preservation over time.",
keywords = "cochlear implantation, cochlear trauma, hearing preservation, image guidance",
author = "Sweeney, {Alex D.} and Hunter, {Jacob B.} and Carlson, {Matthew L.} and Alejandro Rivas and Bennett, {Marc L.} and Gifford, {Rene H.} and Noble, {Jack H.} and Haynes, {David S.} and Labadie, {Robert F.} and Wanna, {George B.}",
year = "2016",
month = "1",
day = "1",
doi = "10.1177/0194599816630545",
language = "English (US)",
volume = "154",
pages = "907--913",
journal = "Otolaryngology - Head and Neck Surgery (United States)",
issn = "0194-5998",
publisher = "Mosby Inc.",
number = "5",

}

TY - JOUR

T1 - Durability of Hearing Preservation after Cochlear Implantation with Conventional-Length Electrodes and Scala Tympani Insertion

AU - Sweeney, Alex D.

AU - Hunter, Jacob B.

AU - Carlson, Matthew L.

AU - Rivas, Alejandro

AU - Bennett, Marc L.

AU - Gifford, Rene H.

AU - Noble, Jack H.

AU - Haynes, David S.

AU - Labadie, Robert F.

AU - Wanna, George B.

PY - 2016/1/1

Y1 - 2016/1/1

N2 - Objectives To analyze factors that influence hearing preservation over time in cochlear implant recipients with conventional-length electrode arrays located entirely within the scala tympani. Study Design Case series with planned chart review. Setting Single tertiary academic referral center. Subjects and Methods A retrospective review was performed to analyze a subgroup of cochlear implant recipients with residual acoustic hearing. Patients were included in the study only if their electrode arrays remained fully in the scala tympani after insertion and serviceable acoustic hearing (≤80 dB at 250 Hz) was preserved. Electrode array location was verified through a validated radiographic assessment tool. Patients with <6 months of audiologic follow-up were excluded. The main outcome measure was change in acoustic hearing thresholds from implant activation to the last available follow-up. Results A total of 16 cases met inclusion criteria (median age, 70.6 years; range, 29.4-82.2; 50% female). The average follow-up was 18.0 months (median, 16.1; range, 6.2-36.4). Patients with a lateral wall electrode array were more likely to have stable acoustic thresholds over time (P <.05). Positive correlations were seen between continued hearing loss following activation and larger initial postoperative acoustic threshold shifts, though statistical significance was not achieved. Age, sex, and noise exposure had no significant influence on continued hearing preservation over time. Conclusions To control for hearing loss associated with interscalar excursion during cochlear implantation, the present study evaluated patients only with conventional electrode arrays located entirely within the scala tympani. In this group, the style of electrode array may influence residual hearing preservation over time.

AB - Objectives To analyze factors that influence hearing preservation over time in cochlear implant recipients with conventional-length electrode arrays located entirely within the scala tympani. Study Design Case series with planned chart review. Setting Single tertiary academic referral center. Subjects and Methods A retrospective review was performed to analyze a subgroup of cochlear implant recipients with residual acoustic hearing. Patients were included in the study only if their electrode arrays remained fully in the scala tympani after insertion and serviceable acoustic hearing (≤80 dB at 250 Hz) was preserved. Electrode array location was verified through a validated radiographic assessment tool. Patients with <6 months of audiologic follow-up were excluded. The main outcome measure was change in acoustic hearing thresholds from implant activation to the last available follow-up. Results A total of 16 cases met inclusion criteria (median age, 70.6 years; range, 29.4-82.2; 50% female). The average follow-up was 18.0 months (median, 16.1; range, 6.2-36.4). Patients with a lateral wall electrode array were more likely to have stable acoustic thresholds over time (P <.05). Positive correlations were seen between continued hearing loss following activation and larger initial postoperative acoustic threshold shifts, though statistical significance was not achieved. Age, sex, and noise exposure had no significant influence on continued hearing preservation over time. Conclusions To control for hearing loss associated with interscalar excursion during cochlear implantation, the present study evaluated patients only with conventional electrode arrays located entirely within the scala tympani. In this group, the style of electrode array may influence residual hearing preservation over time.

KW - cochlear implantation

KW - cochlear trauma

KW - hearing preservation

KW - image guidance

UR - http://www.scopus.com/inward/record.url?scp=84968854635&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84968854635&partnerID=8YFLogxK

U2 - 10.1177/0194599816630545

DO - 10.1177/0194599816630545

M3 - Article

VL - 154

SP - 907

EP - 913

JO - Otolaryngology - Head and Neck Surgery (United States)

JF - Otolaryngology - Head and Neck Surgery (United States)

SN - 0194-5998

IS - 5