Effect of biphasic endocardial countershock on pacing thresholds in humans

D. J. Kessler, R. C. Canby, R. P. Horton, Jose A Joglar, Michael E Jessen, R. L. Page

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

The use of non-thoracotomy endocardial implantable defibrillation with pacing capabilities has increased substantially over the past 2 years. This report demonstrates that the pacing threshold increases in some patients after endocardial defibrillation, and substantiates the practice of using maximal pacing output after endocardial defibrillation.

Original languageEnglish (US)
Pages (from-to)527-528
Number of pages2
JournalAmerican Journal of Cardiology
Volume77
Issue number7
DOIs
StatePublished - 1996

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Effect of biphasic endocardial countershock on pacing thresholds in humans. / Kessler, D. J.; Canby, R. C.; Horton, R. P.; Joglar, Jose A; Jessen, Michael E; Page, R. L.

In: American Journal of Cardiology, Vol. 77, No. 7, 1996, p. 527-528.

Research output: Contribution to journalArticle

Kessler, D. J. ; Canby, R. C. ; Horton, R. P. ; Joglar, Jose A ; Jessen, Michael E ; Page, R. L. / Effect of biphasic endocardial countershock on pacing thresholds in humans. In: American Journal of Cardiology. 1996 ; Vol. 77, No. 7. pp. 527-528.
@article{4ae4d8cb2b774313a3f03826518778c3,
title = "Effect of biphasic endocardial countershock on pacing thresholds in humans",
abstract = "The use of non-thoracotomy endocardial implantable defibrillation with pacing capabilities has increased substantially over the past 2 years. This report demonstrates that the pacing threshold increases in some patients after endocardial defibrillation, and substantiates the practice of using maximal pacing output after endocardial defibrillation.",
author = "Kessler, {D. J.} and Canby, {R. C.} and Horton, {R. P.} and Joglar, {Jose A} and Jessen, {Michael E} and Page, {R. L.}",
year = "1996",
doi = "10.1016/S0002-9149(97)89350-2",
language = "English (US)",
volume = "77",
pages = "527--528",
journal = "American Journal of Cardiology",
issn = "0002-9149",
publisher = "Elsevier Inc.",
number = "7",

}

TY - JOUR

T1 - Effect of biphasic endocardial countershock on pacing thresholds in humans

AU - Kessler, D. J.

AU - Canby, R. C.

AU - Horton, R. P.

AU - Joglar, Jose A

AU - Jessen, Michael E

AU - Page, R. L.

PY - 1996

Y1 - 1996

N2 - The use of non-thoracotomy endocardial implantable defibrillation with pacing capabilities has increased substantially over the past 2 years. This report demonstrates that the pacing threshold increases in some patients after endocardial defibrillation, and substantiates the practice of using maximal pacing output after endocardial defibrillation.

AB - The use of non-thoracotomy endocardial implantable defibrillation with pacing capabilities has increased substantially over the past 2 years. This report demonstrates that the pacing threshold increases in some patients after endocardial defibrillation, and substantiates the practice of using maximal pacing output after endocardial defibrillation.

UR - http://www.scopus.com/inward/record.url?scp=0030003806&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030003806&partnerID=8YFLogxK

U2 - 10.1016/S0002-9149(97)89350-2

DO - 10.1016/S0002-9149(97)89350-2

M3 - Article

VL - 77

SP - 527

EP - 528

JO - American Journal of Cardiology

JF - American Journal of Cardiology

SN - 0002-9149

IS - 7

ER -