T1 - Effect of mesh width on apical support after sacrocolpopexy
AU - Balgobin, Sunil
AU - Fitzwater, Joseph L.
AU - McIntire, Donald D.
AU - Delgado, Imelda J.
AU - Wai, Clifford Y.
N1 - Publisher Copyright:
© 2016, The International Urogynecological Association.
PY - 2017/8/1
Y1 - 2017/8/1
N2 - Introduction and hypothesis: We evaluated the effect of polypropylene mesh width on vaginal apical support, mesh elongation, and mesh tensile strength for abdominal sacrocolpopexy. Methods: Abdominal sacrocolpopexy was performed on ten cadavers using pieces of polypropylene mesh of width 1, 2, and 3 cm. Weights of 1, 2, 3, and 4 kg were sequentially applied to the vagina. The total distance moved by the vaginal apex, and the amount of stretch of the intervening mesh segment between the sacrum and the vagina were recorded for each width. The failure strengths of additional single and double layer sets of each width were also tested using a tensiometer. Data were analyzed with analysis of variance using a random effects model. Results: The mean (standard error of the mean) maximum distance moved by the vaginal apex was 4.63 cm (0.37 cm) for the 1 cm mesh compared to 3.67 cm (0.26 cm) and 2.73 cm (0.14 cm) for the 2 and 3 cm meshes, respectively (P < 0.0001). The 1 cm width ruptured during testing in four of the ten cadavers. The results were similar for mesh elongation, with the 1 cm mesh stretching the most and the 3 cm mesh stretching the least. Mesh failure loads for double-layer mesh were 52.9 N (2.5 N), 124.4 N (2.7 N), and 201.2 N (4.5 N) for the 1, 2, and 3 cm meshes, respectively, and were higher than the failure loads for single mesh (P < 0.001). Conclusions: In a cadaver model, increasing mesh width is associated with better vaginal apical support, less mesh elongation, and higher failure loads. Mesh widths of 2–3 cm provide sufficient repair strength for sacrocolpopexy.
AB - Introduction and hypothesis: We evaluated the effect of polypropylene mesh width on vaginal apical support, mesh elongation, and mesh tensile strength for abdominal sacrocolpopexy. Methods: Abdominal sacrocolpopexy was performed on ten cadavers using pieces of polypropylene mesh of width 1, 2, and 3 cm. Weights of 1, 2, 3, and 4 kg were sequentially applied to the vagina. The total distance moved by the vaginal apex, and the amount of stretch of the intervening mesh segment between the sacrum and the vagina were recorded for each width. The failure strengths of additional single and double layer sets of each width were also tested using a tensiometer. Data were analyzed with analysis of variance using a random effects model. Results: The mean (standard error of the mean) maximum distance moved by the vaginal apex was 4.63 cm (0.37 cm) for the 1 cm mesh compared to 3.67 cm (0.26 cm) and 2.73 cm (0.14 cm) for the 2 and 3 cm meshes, respectively (P < 0.0001). The 1 cm width ruptured during testing in four of the ten cadavers. The results were similar for mesh elongation, with the 1 cm mesh stretching the most and the 3 cm mesh stretching the least. Mesh failure loads for double-layer mesh were 52.9 N (2.5 N), 124.4 N (2.7 N), and 201.2 N (4.5 N) for the 1, 2, and 3 cm meshes, respectively, and were higher than the failure loads for single mesh (P < 0.001). Conclusions: In a cadaver model, increasing mesh width is associated with better vaginal apical support, less mesh elongation, and higher failure loads. Mesh widths of 2–3 cm provide sufficient repair strength for sacrocolpopexy.
KW - Biomechanics
KW - Mesh width
KW - Polypropylene mesh
KW - Sacrocolpopexy
UR - http://www.scopus.com/inward/record.url?scp=85007453620&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85007453620&partnerID=8YFLogxK
U2 - 10.1007/s00192-016-3250-y
DO - 10.1007/s00192-016-3250-y
M3 - Article
C2 - 28035443
AN - SCOPUS:85007453620
SN - 0937-3462
VL - 28
SP - 1153
EP - 1158
JO - International Urogynecology Journal
JF - International Urogynecology Journal
IS - 8
ER -