Effects of rigid lens extended wear on lactate dehydrogenase activity and isozymes in rabbit tears

H. Ichijima, H. D. Cavanagh

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Effects of and recovery from continuous wear of four rigid gas permeable (RGP) contact lenses was assessed by noninvasive measurement of lactate dehydrogenase (LDH) activity and isozyme pattern in rabbit tears. Oxygen transmissibility (Dk/L) of lenses used was 27, 44, 84, and 97 x 10-9 (cm/s)(ml O2/ml mm Hg); lens thickness (0.15 mm) and diameter (14.0 mm) were standardized. Lenses were worn continuously for 90 days; recovery was assessed 30 days after cessation of lens wear. LDH activity was measured by UV rate assay; isozyme subtypes were determined by agarose gel electrophoresis. Light and scanning electron microscopy (LM, SEM) were used with the determination of total protein as additional measures of lens effects. LDH levels were inversely correlated with lens Dk/L values; low Dk/L values increased the anaerobic (LDH4.5)/aerobic (LDH1,2,3) subtype(n) ratio indicating in vivo metabolic shift. SEM observations were consistent with these results. There was no significant difference in the total cell content of tears or total tear protein levels between control and RGP test- wear groups. Measurement of tear LDH activity and isozyme ratios appears to provide a sensitive, noninvasive assessment of the effects of RGP lens- induced hypoxia over time on the corneal surface. A level of Dk/L of ≥84 appears best for maintaining corneal physiology during extended wear. Recovery from chronic lens-induced hypoxia is characterized by a return to normal tear LDH levels and isozyme subtypes.

Original languageEnglish (US)
Pages (from-to)429-434
Number of pages6
JournalCornea
Volume13
Issue number5
DOIs
StatePublished - 1994

Fingerprint

Tears
L-Lactate Dehydrogenase
Lenses
Isoenzymes
Rabbits
Gases
Agar Gel Electrophoresis
Contact Lenses
Electron Scanning Microscopy
Oxygen
Light
Proteins

Keywords

  • Contact lenses
  • Isozyme
  • Lactate dehydrogenase
  • Tears

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Effects of rigid lens extended wear on lactate dehydrogenase activity and isozymes in rabbit tears. / Ichijima, H.; Cavanagh, H. D.

In: Cornea, Vol. 13, No. 5, 1994, p. 429-434.

Research output: Contribution to journalArticle

@article{10d96ec83234468bb7f56b27c6546368,
title = "Effects of rigid lens extended wear on lactate dehydrogenase activity and isozymes in rabbit tears",
abstract = "Effects of and recovery from continuous wear of four rigid gas permeable (RGP) contact lenses was assessed by noninvasive measurement of lactate dehydrogenase (LDH) activity and isozyme pattern in rabbit tears. Oxygen transmissibility (Dk/L) of lenses used was 27, 44, 84, and 97 x 10-9 (cm/s)(ml O2/ml mm Hg); lens thickness (0.15 mm) and diameter (14.0 mm) were standardized. Lenses were worn continuously for 90 days; recovery was assessed 30 days after cessation of lens wear. LDH activity was measured by UV rate assay; isozyme subtypes were determined by agarose gel electrophoresis. Light and scanning electron microscopy (LM, SEM) were used with the determination of total protein as additional measures of lens effects. LDH levels were inversely correlated with lens Dk/L values; low Dk/L values increased the anaerobic (LDH4.5)/aerobic (LDH1,2,3) subtype(n) ratio indicating in vivo metabolic shift. SEM observations were consistent with these results. There was no significant difference in the total cell content of tears or total tear protein levels between control and RGP test- wear groups. Measurement of tear LDH activity and isozyme ratios appears to provide a sensitive, noninvasive assessment of the effects of RGP lens- induced hypoxia over time on the corneal surface. A level of Dk/L of ≥84 appears best for maintaining corneal physiology during extended wear. Recovery from chronic lens-induced hypoxia is characterized by a return to normal tear LDH levels and isozyme subtypes.",
keywords = "Contact lenses, Isozyme, Lactate dehydrogenase, Tears",
author = "H. Ichijima and Cavanagh, {H. D.}",
year = "1994",
doi = "10.1097/00003226-199409000-00010",
language = "English (US)",
volume = "13",
pages = "429--434",
journal = "Cornea",
issn = "0277-3740",
publisher = "Lippincott Williams and Wilkins",
number = "5",

}

TY - JOUR

T1 - Effects of rigid lens extended wear on lactate dehydrogenase activity and isozymes in rabbit tears

AU - Ichijima, H.

AU - Cavanagh, H. D.

PY - 1994

Y1 - 1994

N2 - Effects of and recovery from continuous wear of four rigid gas permeable (RGP) contact lenses was assessed by noninvasive measurement of lactate dehydrogenase (LDH) activity and isozyme pattern in rabbit tears. Oxygen transmissibility (Dk/L) of lenses used was 27, 44, 84, and 97 x 10-9 (cm/s)(ml O2/ml mm Hg); lens thickness (0.15 mm) and diameter (14.0 mm) were standardized. Lenses were worn continuously for 90 days; recovery was assessed 30 days after cessation of lens wear. LDH activity was measured by UV rate assay; isozyme subtypes were determined by agarose gel electrophoresis. Light and scanning electron microscopy (LM, SEM) were used with the determination of total protein as additional measures of lens effects. LDH levels were inversely correlated with lens Dk/L values; low Dk/L values increased the anaerobic (LDH4.5)/aerobic (LDH1,2,3) subtype(n) ratio indicating in vivo metabolic shift. SEM observations were consistent with these results. There was no significant difference in the total cell content of tears or total tear protein levels between control and RGP test- wear groups. Measurement of tear LDH activity and isozyme ratios appears to provide a sensitive, noninvasive assessment of the effects of RGP lens- induced hypoxia over time on the corneal surface. A level of Dk/L of ≥84 appears best for maintaining corneal physiology during extended wear. Recovery from chronic lens-induced hypoxia is characterized by a return to normal tear LDH levels and isozyme subtypes.

AB - Effects of and recovery from continuous wear of four rigid gas permeable (RGP) contact lenses was assessed by noninvasive measurement of lactate dehydrogenase (LDH) activity and isozyme pattern in rabbit tears. Oxygen transmissibility (Dk/L) of lenses used was 27, 44, 84, and 97 x 10-9 (cm/s)(ml O2/ml mm Hg); lens thickness (0.15 mm) and diameter (14.0 mm) were standardized. Lenses were worn continuously for 90 days; recovery was assessed 30 days after cessation of lens wear. LDH activity was measured by UV rate assay; isozyme subtypes were determined by agarose gel electrophoresis. Light and scanning electron microscopy (LM, SEM) were used with the determination of total protein as additional measures of lens effects. LDH levels were inversely correlated with lens Dk/L values; low Dk/L values increased the anaerobic (LDH4.5)/aerobic (LDH1,2,3) subtype(n) ratio indicating in vivo metabolic shift. SEM observations were consistent with these results. There was no significant difference in the total cell content of tears or total tear protein levels between control and RGP test- wear groups. Measurement of tear LDH activity and isozyme ratios appears to provide a sensitive, noninvasive assessment of the effects of RGP lens- induced hypoxia over time on the corneal surface. A level of Dk/L of ≥84 appears best for maintaining corneal physiology during extended wear. Recovery from chronic lens-induced hypoxia is characterized by a return to normal tear LDH levels and isozyme subtypes.

KW - Contact lenses

KW - Isozyme

KW - Lactate dehydrogenase

KW - Tears

UR - http://www.scopus.com/inward/record.url?scp=0027992493&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027992493&partnerID=8YFLogxK

U2 - 10.1097/00003226-199409000-00010

DO - 10.1097/00003226-199409000-00010

M3 - Article

C2 - 7995067

AN - SCOPUS:0027992493

VL - 13

SP - 429

EP - 434

JO - Cornea

JF - Cornea

SN - 0277-3740

IS - 5

ER -