Evaluation of novel direct and indirect detection active matrix, flat-panel imagers (AMFPIs) for mammography

Youcef El-Mohri, Larry E. Antonuk, Kyung Wook Jee, Yixiu Kang, Yixin Li, Amit Sawant, Zhong Su, Yi Wang, Jin Yamamoto, Qihua Zhao

Research output: Chapter in Book/Report/Conference proceedingConference contribution

13 Citations (Scopus)

Abstract

A performance evaluation of small-area, high-spatial-resolution, active matrix flat-panel imager (AMFPI) prototypes, operated under mammographic conditions, is reported. These prototypes are based on two 512×512 pixel imagers employing novel designs to enhance signal performance for direct and indirect detection. The indirect detection prototype is based on a 75 μm pixel pitch array incorporating a continuous photodiode design, as opposed to the discrete photodiode design used in conventional flat-panel imagers. This array was coupled to a pair of commercially-available x-ray converters: (a) a 34 mg/cm 2 Gd 2O 2S:Tb phosphor screen (Min-R, Kodak) and (b) a 150 μm thick structured CsI:Tl scintillator on a fiber-optic plate (FOS-HL, Hamamatsu). The direct detection prototype is based on a 100 μm pixel pitch array and uses a 240 μm thick, high gain mercuric iodide (HgI 2) photoconductor. Measurements of sensitivity, MTF, NFS and DQE were performed with a 26 kVp mammography beam attenuated by a 4 cm BR-12 breast phantom at various radiation exposures. Results from empirical studies of sensitivity indicate that these imagers offer a substantial enhancement in signal over conventional flat-panel imagers. Measurements of DQE for the imagers show values greater than those obtained from high performance mammographic film-screen systems, under some conditions. These studies also show that the FOS-HL imager configuration, despite its lower MTF, exhibits DQE performance (up to ∼0.77) superior or equivalent to that of the Min-R configuration due to better optical properties of the converter. In addition, despite a smaller pixel pitch, both of these indirect detection configurations exhibit improved DQE in comparison to similar configurations employing a 97 μm pitch discrete photodiode design, especially at low exposures. Results of DQE measurements from the HgI 2 photoconductor prototype are promising (DQE values up to ∼0.6). Finally, calculations of potential DQE performance for hypothetical 50 μm pitch imagers, employing similar novel designs, were performed. These calculations were based on the cascaded systems formalism and used realistic inputs derived from empirical measurements. The results predict that the HgI 2 configuration would provide high DQE performance (up to ∼0.9), which would be largely unaffected by the magnitude of exposure, due to the high gain of the photoconductor. These calculations also indicate that the continuous photodiode configuration would provide high DQE (up to ∼0.8), degraded only at low exposure by the effect of additive noise.

Original languageEnglish (US)
Title of host publicationProceedings of SPIE - The International Society for Optical Engineering
EditorsM.J. Yaffe, L.E. Antonuk
Pages168-180
Number of pages13
Volume5030 I
DOIs
StatePublished - 2003
EventMedical Imaging 2003: Physics of Medical Imaging - San Diego, CA, United States
Duration: Feb 16 2003Feb 18 2003

Other

OtherMedical Imaging 2003: Physics of Medical Imaging
CountryUnited States
CitySan Diego, CA
Period2/16/032/18/03

Fingerprint

Mammography
Image sensors
prototypes
photodiodes
photoconductors
evaluation
matrices
configurations
Photodiodes
pixels
Photoconducting materials
Pixels
modulation transfer function
high gain
converters
Phosphors
sensitivity
radiation dosage
breast
iodides

Keywords

  • Active matrix flat-panel imager
  • Cascaded systems modeling
  • Digital mammography
  • Direct detection
  • Indirect detection

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Condensed Matter Physics

Cite this

El-Mohri, Y., Antonuk, L. E., Jee, K. W., Kang, Y., Li, Y., Sawant, A., ... Zhao, Q. (2003). Evaluation of novel direct and indirect detection active matrix, flat-panel imagers (AMFPIs) for mammography. In M. J. Yaffe, & L. E. Antonuk (Eds.), Proceedings of SPIE - The International Society for Optical Engineering (Vol. 5030 I, pp. 168-180) https://doi.org/10.1117/12.484071

Evaluation of novel direct and indirect detection active matrix, flat-panel imagers (AMFPIs) for mammography. / El-Mohri, Youcef; Antonuk, Larry E.; Jee, Kyung Wook; Kang, Yixiu; Li, Yixin; Sawant, Amit; Su, Zhong; Wang, Yi; Yamamoto, Jin; Zhao, Qihua.

Proceedings of SPIE - The International Society for Optical Engineering. ed. / M.J. Yaffe; L.E. Antonuk. Vol. 5030 I 2003. p. 168-180.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

El-Mohri, Y, Antonuk, LE, Jee, KW, Kang, Y, Li, Y, Sawant, A, Su, Z, Wang, Y, Yamamoto, J & Zhao, Q 2003, Evaluation of novel direct and indirect detection active matrix, flat-panel imagers (AMFPIs) for mammography. in MJ Yaffe & LE Antonuk (eds), Proceedings of SPIE - The International Society for Optical Engineering. vol. 5030 I, pp. 168-180, Medical Imaging 2003: Physics of Medical Imaging, San Diego, CA, United States, 2/16/03. https://doi.org/10.1117/12.484071
El-Mohri Y, Antonuk LE, Jee KW, Kang Y, Li Y, Sawant A et al. Evaluation of novel direct and indirect detection active matrix, flat-panel imagers (AMFPIs) for mammography. In Yaffe MJ, Antonuk LE, editors, Proceedings of SPIE - The International Society for Optical Engineering. Vol. 5030 I. 2003. p. 168-180 https://doi.org/10.1117/12.484071
El-Mohri, Youcef ; Antonuk, Larry E. ; Jee, Kyung Wook ; Kang, Yixiu ; Li, Yixin ; Sawant, Amit ; Su, Zhong ; Wang, Yi ; Yamamoto, Jin ; Zhao, Qihua. / Evaluation of novel direct and indirect detection active matrix, flat-panel imagers (AMFPIs) for mammography. Proceedings of SPIE - The International Society for Optical Engineering. editor / M.J. Yaffe ; L.E. Antonuk. Vol. 5030 I 2003. pp. 168-180
@inproceedings{b41a9963c24f470886c02559c49bed4b,
title = "Evaluation of novel direct and indirect detection active matrix, flat-panel imagers (AMFPIs) for mammography",
abstract = "A performance evaluation of small-area, high-spatial-resolution, active matrix flat-panel imager (AMFPI) prototypes, operated under mammographic conditions, is reported. These prototypes are based on two 512×512 pixel imagers employing novel designs to enhance signal performance for direct and indirect detection. The indirect detection prototype is based on a 75 μm pixel pitch array incorporating a continuous photodiode design, as opposed to the discrete photodiode design used in conventional flat-panel imagers. This array was coupled to a pair of commercially-available x-ray converters: (a) a 34 mg/cm 2 Gd 2O 2S:Tb phosphor screen (Min-R, Kodak) and (b) a 150 μm thick structured CsI:Tl scintillator on a fiber-optic plate (FOS-HL, Hamamatsu). The direct detection prototype is based on a 100 μm pixel pitch array and uses a 240 μm thick, high gain mercuric iodide (HgI 2) photoconductor. Measurements of sensitivity, MTF, NFS and DQE were performed with a 26 kVp mammography beam attenuated by a 4 cm BR-12 breast phantom at various radiation exposures. Results from empirical studies of sensitivity indicate that these imagers offer a substantial enhancement in signal over conventional flat-panel imagers. Measurements of DQE for the imagers show values greater than those obtained from high performance mammographic film-screen systems, under some conditions. These studies also show that the FOS-HL imager configuration, despite its lower MTF, exhibits DQE performance (up to ∼0.77) superior or equivalent to that of the Min-R configuration due to better optical properties of the converter. In addition, despite a smaller pixel pitch, both of these indirect detection configurations exhibit improved DQE in comparison to similar configurations employing a 97 μm pitch discrete photodiode design, especially at low exposures. Results of DQE measurements from the HgI 2 photoconductor prototype are promising (DQE values up to ∼0.6). Finally, calculations of potential DQE performance for hypothetical 50 μm pitch imagers, employing similar novel designs, were performed. These calculations were based on the cascaded systems formalism and used realistic inputs derived from empirical measurements. The results predict that the HgI 2 configuration would provide high DQE performance (up to ∼0.9), which would be largely unaffected by the magnitude of exposure, due to the high gain of the photoconductor. These calculations also indicate that the continuous photodiode configuration would provide high DQE (up to ∼0.8), degraded only at low exposure by the effect of additive noise.",
keywords = "Active matrix flat-panel imager, Cascaded systems modeling, Digital mammography, Direct detection, Indirect detection",
author = "Youcef El-Mohri and Antonuk, {Larry E.} and Jee, {Kyung Wook} and Yixiu Kang and Yixin Li and Amit Sawant and Zhong Su and Yi Wang and Jin Yamamoto and Qihua Zhao",
year = "2003",
doi = "10.1117/12.484071",
language = "English (US)",
volume = "5030 I",
pages = "168--180",
editor = "M.J. Yaffe and L.E. Antonuk",
booktitle = "Proceedings of SPIE - The International Society for Optical Engineering",

}

TY - GEN

T1 - Evaluation of novel direct and indirect detection active matrix, flat-panel imagers (AMFPIs) for mammography

AU - El-Mohri, Youcef

AU - Antonuk, Larry E.

AU - Jee, Kyung Wook

AU - Kang, Yixiu

AU - Li, Yixin

AU - Sawant, Amit

AU - Su, Zhong

AU - Wang, Yi

AU - Yamamoto, Jin

AU - Zhao, Qihua

PY - 2003

Y1 - 2003

N2 - A performance evaluation of small-area, high-spatial-resolution, active matrix flat-panel imager (AMFPI) prototypes, operated under mammographic conditions, is reported. These prototypes are based on two 512×512 pixel imagers employing novel designs to enhance signal performance for direct and indirect detection. The indirect detection prototype is based on a 75 μm pixel pitch array incorporating a continuous photodiode design, as opposed to the discrete photodiode design used in conventional flat-panel imagers. This array was coupled to a pair of commercially-available x-ray converters: (a) a 34 mg/cm 2 Gd 2O 2S:Tb phosphor screen (Min-R, Kodak) and (b) a 150 μm thick structured CsI:Tl scintillator on a fiber-optic plate (FOS-HL, Hamamatsu). The direct detection prototype is based on a 100 μm pixel pitch array and uses a 240 μm thick, high gain mercuric iodide (HgI 2) photoconductor. Measurements of sensitivity, MTF, NFS and DQE were performed with a 26 kVp mammography beam attenuated by a 4 cm BR-12 breast phantom at various radiation exposures. Results from empirical studies of sensitivity indicate that these imagers offer a substantial enhancement in signal over conventional flat-panel imagers. Measurements of DQE for the imagers show values greater than those obtained from high performance mammographic film-screen systems, under some conditions. These studies also show that the FOS-HL imager configuration, despite its lower MTF, exhibits DQE performance (up to ∼0.77) superior or equivalent to that of the Min-R configuration due to better optical properties of the converter. In addition, despite a smaller pixel pitch, both of these indirect detection configurations exhibit improved DQE in comparison to similar configurations employing a 97 μm pitch discrete photodiode design, especially at low exposures. Results of DQE measurements from the HgI 2 photoconductor prototype are promising (DQE values up to ∼0.6). Finally, calculations of potential DQE performance for hypothetical 50 μm pitch imagers, employing similar novel designs, were performed. These calculations were based on the cascaded systems formalism and used realistic inputs derived from empirical measurements. The results predict that the HgI 2 configuration would provide high DQE performance (up to ∼0.9), which would be largely unaffected by the magnitude of exposure, due to the high gain of the photoconductor. These calculations also indicate that the continuous photodiode configuration would provide high DQE (up to ∼0.8), degraded only at low exposure by the effect of additive noise.

AB - A performance evaluation of small-area, high-spatial-resolution, active matrix flat-panel imager (AMFPI) prototypes, operated under mammographic conditions, is reported. These prototypes are based on two 512×512 pixel imagers employing novel designs to enhance signal performance for direct and indirect detection. The indirect detection prototype is based on a 75 μm pixel pitch array incorporating a continuous photodiode design, as opposed to the discrete photodiode design used in conventional flat-panel imagers. This array was coupled to a pair of commercially-available x-ray converters: (a) a 34 mg/cm 2 Gd 2O 2S:Tb phosphor screen (Min-R, Kodak) and (b) a 150 μm thick structured CsI:Tl scintillator on a fiber-optic plate (FOS-HL, Hamamatsu). The direct detection prototype is based on a 100 μm pixel pitch array and uses a 240 μm thick, high gain mercuric iodide (HgI 2) photoconductor. Measurements of sensitivity, MTF, NFS and DQE were performed with a 26 kVp mammography beam attenuated by a 4 cm BR-12 breast phantom at various radiation exposures. Results from empirical studies of sensitivity indicate that these imagers offer a substantial enhancement in signal over conventional flat-panel imagers. Measurements of DQE for the imagers show values greater than those obtained from high performance mammographic film-screen systems, under some conditions. These studies also show that the FOS-HL imager configuration, despite its lower MTF, exhibits DQE performance (up to ∼0.77) superior or equivalent to that of the Min-R configuration due to better optical properties of the converter. In addition, despite a smaller pixel pitch, both of these indirect detection configurations exhibit improved DQE in comparison to similar configurations employing a 97 μm pitch discrete photodiode design, especially at low exposures. Results of DQE measurements from the HgI 2 photoconductor prototype are promising (DQE values up to ∼0.6). Finally, calculations of potential DQE performance for hypothetical 50 μm pitch imagers, employing similar novel designs, were performed. These calculations were based on the cascaded systems formalism and used realistic inputs derived from empirical measurements. The results predict that the HgI 2 configuration would provide high DQE performance (up to ∼0.9), which would be largely unaffected by the magnitude of exposure, due to the high gain of the photoconductor. These calculations also indicate that the continuous photodiode configuration would provide high DQE (up to ∼0.8), degraded only at low exposure by the effect of additive noise.

KW - Active matrix flat-panel imager

KW - Cascaded systems modeling

KW - Digital mammography

KW - Direct detection

KW - Indirect detection

UR - http://www.scopus.com/inward/record.url?scp=0037774458&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037774458&partnerID=8YFLogxK

U2 - 10.1117/12.484071

DO - 10.1117/12.484071

M3 - Conference contribution

AN - SCOPUS:0037774458

VL - 5030 I

SP - 168

EP - 180

BT - Proceedings of SPIE - The International Society for Optical Engineering

A2 - Yaffe, M.J.

A2 - Antonuk, L.E.

ER -