Falsely increased i-STAT chloride results for blood samples with increased urea

J. K. Pinckard, J. Zahn, L. Ashby, C. A. Parvin, M. G. Scott

Research output: Contribution to journalArticle

9 Citations (Scopus)
Original languageEnglish (US)
Pages (from-to)2064-2066
Number of pages3
JournalClinical Chemistry
Volume47
Issue number11
StatePublished - 2001

Fingerprint

Diagnostic Reagent Kits
Point-of-Care Systems
False Positive Reactions
Kidney Diseases
Urea
Chlorides
Blood

ASJC Scopus subject areas

  • Clinical Biochemistry

Cite this

Pinckard, J. K., Zahn, J., Ashby, L., Parvin, C. A., & Scott, M. G. (2001). Falsely increased i-STAT chloride results for blood samples with increased urea. Clinical Chemistry, 47(11), 2064-2066.

Falsely increased i-STAT chloride results for blood samples with increased urea. / Pinckard, J. K.; Zahn, J.; Ashby, L.; Parvin, C. A.; Scott, M. G.

In: Clinical Chemistry, Vol. 47, No. 11, 2001, p. 2064-2066.

Research output: Contribution to journalArticle

Pinckard, JK, Zahn, J, Ashby, L, Parvin, CA & Scott, MG 2001, 'Falsely increased i-STAT chloride results for blood samples with increased urea', Clinical Chemistry, vol. 47, no. 11, pp. 2064-2066.
Pinckard JK, Zahn J, Ashby L, Parvin CA, Scott MG. Falsely increased i-STAT chloride results for blood samples with increased urea. Clinical Chemistry. 2001;47(11):2064-2066.
Pinckard, J. K. ; Zahn, J. ; Ashby, L. ; Parvin, C. A. ; Scott, M. G. / Falsely increased i-STAT chloride results for blood samples with increased urea. In: Clinical Chemistry. 2001 ; Vol. 47, No. 11. pp. 2064-2066.
@article{e2cc9100237b4800bb3b868a5fcb9103,
title = "Falsely increased i-STAT chloride results for blood samples with increased urea",
author = "Pinckard, {J. K.} and J. Zahn and L. Ashby and Parvin, {C. A.} and Scott, {M. G.}",
year = "2001",
language = "English (US)",
volume = "47",
pages = "2064--2066",
journal = "Clinical Chemistry",
issn = "0009-9147",
publisher = "American Association for Clinical Chemistry Inc.",
number = "11",

}

TY - JOUR

T1 - Falsely increased i-STAT chloride results for blood samples with increased urea

AU - Pinckard, J. K.

AU - Zahn, J.

AU - Ashby, L.

AU - Parvin, C. A.

AU - Scott, M. G.

PY - 2001

Y1 - 2001

UR - http://www.scopus.com/inward/record.url?scp=0034771690&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034771690&partnerID=8YFLogxK

M3 - Article

C2 - 11673386

AN - SCOPUS:0034771690

VL - 47

SP - 2064

EP - 2066

JO - Clinical Chemistry

JF - Clinical Chemistry

SN - 0009-9147

IS - 11

ER -