Currently, high-precision delivery in stereotactic radiosurgery (SRS) is achieved via high-precision target localization and rigid patient immobilization. Rigid patient immobilization can result in, however, patient discomfort, which is exacerbated by the long duration of SRS treatments and may induce patient movement. To address this issue, we developed a new SRS technique that is aimed to minimize patient discomfort while maintaining high-precision treatment, based on a less-rigid patient immobilization combined with continuous patient motion monitoring. In this paper, we examine the feasibility of this new technique. An anthropomorphic head phantom is used to check the accuracy of a 3D surface imaging system that provides the monitoring. Volunteers are used to study patient motion inside a new type of head mold that is used for minimal immobilization. Results show that for different couch angles, the difference between the phantom positions recorded by the surface imaging system and by an infrared optical tracking system was within 1 mm in displacements and 1° in rotation. The motion detected by both systems during couch shifts is within 1 mm agreement. The average maximum volunteer head motion in the head mold during the 20 min interval in any direction was 0.7 mm (range: 0.4-1.1 mm). Patient motion due to couch motion was always less than 0.2 mm. We conclude that motion inside the minimally immobilizing head mold is small and can be accurately detected by real-time surface imaging.

Original languageEnglish (US)
Pages (from-to)1863-1873
Number of pages11
JournalPhysics in Medicine and Biology
Volume55
Issue number7
DOIs
StatePublished - 2010

Fingerprint

Radiosurgery
Feasibility Studies
Masks
Immobilization
Head
Fungi
Volunteers
Stereotaxic Techniques
Optical Devices
Physiologic Monitoring
Therapeutics

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Frame-less and mask-less cranial stereotactic radiosurgery : A feasibility study. / Cervĩo, Laura I.; Pawlicki, Todd; Lawson, Joshua D.; Jiang, Steve B.

In: Physics in Medicine and Biology, Vol. 55, No. 7, 2010, p. 1863-1873.

Research output: Contribution to journalArticle

Cervĩo, Laura I. ; Pawlicki, Todd ; Lawson, Joshua D. ; Jiang, Steve B. / Frame-less and mask-less cranial stereotactic radiosurgery : A feasibility study. In: Physics in Medicine and Biology. 2010 ; Vol. 55, No. 7. pp. 1863-1873.
@article{9c19c4dcd9114fd5b2c95334bf54852b,
title = "Frame-less and mask-less cranial stereotactic radiosurgery: A feasibility study",
abstract = "Currently, high-precision delivery in stereotactic radiosurgery (SRS) is achieved via high-precision target localization and rigid patient immobilization. Rigid patient immobilization can result in, however, patient discomfort, which is exacerbated by the long duration of SRS treatments and may induce patient movement. To address this issue, we developed a new SRS technique that is aimed to minimize patient discomfort while maintaining high-precision treatment, based on a less-rigid patient immobilization combined with continuous patient motion monitoring. In this paper, we examine the feasibility of this new technique. An anthropomorphic head phantom is used to check the accuracy of a 3D surface imaging system that provides the monitoring. Volunteers are used to study patient motion inside a new type of head mold that is used for minimal immobilization. Results show that for different couch angles, the difference between the phantom positions recorded by the surface imaging system and by an infrared optical tracking system was within 1 mm in displacements and 1° in rotation. The motion detected by both systems during couch shifts is within 1 mm agreement. The average maximum volunteer head motion in the head mold during the 20 min interval in any direction was 0.7 mm (range: 0.4-1.1 mm). Patient motion due to couch motion was always less than 0.2 mm. We conclude that motion inside the minimally immobilizing head mold is small and can be accurately detected by real-time surface imaging.",
author = "Cervĩo, {Laura I.} and Todd Pawlicki and Lawson, {Joshua D.} and Jiang, {Steve B.}",
year = "2010",
doi = "10.1088/0031-9155/55/7/005",
language = "English (US)",
volume = "55",
pages = "1863--1873",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "7",

}

TY - JOUR

T1 - Frame-less and mask-less cranial stereotactic radiosurgery

T2 - A feasibility study

AU - Cervĩo, Laura I.

AU - Pawlicki, Todd

AU - Lawson, Joshua D.

AU - Jiang, Steve B.

PY - 2010

Y1 - 2010

N2 - Currently, high-precision delivery in stereotactic radiosurgery (SRS) is achieved via high-precision target localization and rigid patient immobilization. Rigid patient immobilization can result in, however, patient discomfort, which is exacerbated by the long duration of SRS treatments and may induce patient movement. To address this issue, we developed a new SRS technique that is aimed to minimize patient discomfort while maintaining high-precision treatment, based on a less-rigid patient immobilization combined with continuous patient motion monitoring. In this paper, we examine the feasibility of this new technique. An anthropomorphic head phantom is used to check the accuracy of a 3D surface imaging system that provides the monitoring. Volunteers are used to study patient motion inside a new type of head mold that is used for minimal immobilization. Results show that for different couch angles, the difference between the phantom positions recorded by the surface imaging system and by an infrared optical tracking system was within 1 mm in displacements and 1° in rotation. The motion detected by both systems during couch shifts is within 1 mm agreement. The average maximum volunteer head motion in the head mold during the 20 min interval in any direction was 0.7 mm (range: 0.4-1.1 mm). Patient motion due to couch motion was always less than 0.2 mm. We conclude that motion inside the minimally immobilizing head mold is small and can be accurately detected by real-time surface imaging.

AB - Currently, high-precision delivery in stereotactic radiosurgery (SRS) is achieved via high-precision target localization and rigid patient immobilization. Rigid patient immobilization can result in, however, patient discomfort, which is exacerbated by the long duration of SRS treatments and may induce patient movement. To address this issue, we developed a new SRS technique that is aimed to minimize patient discomfort while maintaining high-precision treatment, based on a less-rigid patient immobilization combined with continuous patient motion monitoring. In this paper, we examine the feasibility of this new technique. An anthropomorphic head phantom is used to check the accuracy of a 3D surface imaging system that provides the monitoring. Volunteers are used to study patient motion inside a new type of head mold that is used for minimal immobilization. Results show that for different couch angles, the difference between the phantom positions recorded by the surface imaging system and by an infrared optical tracking system was within 1 mm in displacements and 1° in rotation. The motion detected by both systems during couch shifts is within 1 mm agreement. The average maximum volunteer head motion in the head mold during the 20 min interval in any direction was 0.7 mm (range: 0.4-1.1 mm). Patient motion due to couch motion was always less than 0.2 mm. We conclude that motion inside the minimally immobilizing head mold is small and can be accurately detected by real-time surface imaging.

UR - http://www.scopus.com/inward/record.url?scp=77949704300&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77949704300&partnerID=8YFLogxK

U2 - 10.1088/0031-9155/55/7/005

DO - 10.1088/0031-9155/55/7/005

M3 - Article

C2 - 20224158

AN - SCOPUS:77949704300

VL - 55

SP - 1863

EP - 1873

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 7

ER -