Gated sodium-23 nuclear magnetic resonance images of an isolated perfused working rat heart

Jean L. DeLayre, Joanne S. Ingwall, Craig Malloy, Eric T. Fossel

Research output: Contribution to journalArticle

53 Citations (Scopus)

Abstract

Sodium-23 nuclear magnetic resonance images of phantoms and gated images of isolated perfused working rat hearts were obtained. By synchronizing the nuclear magnetic resonance process to the heartbeat, images were obtained at systole and at diastole.

Original languageEnglish (US)
Pages (from-to)935-936
Number of pages2
JournalScience
Volume212
Issue number4497
StatePublished - 1981

Fingerprint

Magnetic Resonance Spectroscopy
Sodium
Diastole
Systole

ASJC Scopus subject areas

  • General

Cite this

DeLayre, J. L., Ingwall, J. S., Malloy, C., & Fossel, E. T. (1981). Gated sodium-23 nuclear magnetic resonance images of an isolated perfused working rat heart. Science, 212(4497), 935-936.

Gated sodium-23 nuclear magnetic resonance images of an isolated perfused working rat heart. / DeLayre, Jean L.; Ingwall, Joanne S.; Malloy, Craig; Fossel, Eric T.

In: Science, Vol. 212, No. 4497, 1981, p. 935-936.

Research output: Contribution to journalArticle

DeLayre, JL, Ingwall, JS, Malloy, C & Fossel, ET 1981, 'Gated sodium-23 nuclear magnetic resonance images of an isolated perfused working rat heart', Science, vol. 212, no. 4497, pp. 935-936.
DeLayre, Jean L. ; Ingwall, Joanne S. ; Malloy, Craig ; Fossel, Eric T. / Gated sodium-23 nuclear magnetic resonance images of an isolated perfused working rat heart. In: Science. 1981 ; Vol. 212, No. 4497. pp. 935-936.
@article{17bc8413f5884baa818eaf82ffbc72f9,
title = "Gated sodium-23 nuclear magnetic resonance images of an isolated perfused working rat heart",
abstract = "Sodium-23 nuclear magnetic resonance images of phantoms and gated images of isolated perfused working rat hearts were obtained. By synchronizing the nuclear magnetic resonance process to the heartbeat, images were obtained at systole and at diastole.",
author = "DeLayre, {Jean L.} and Ingwall, {Joanne S.} and Craig Malloy and Fossel, {Eric T.}",
year = "1981",
language = "English (US)",
volume = "212",
pages = "935--936",
journal = "Science",
issn = "0036-8075",
publisher = "American Association for the Advancement of Science",
number = "4497",

}

TY - JOUR

T1 - Gated sodium-23 nuclear magnetic resonance images of an isolated perfused working rat heart

AU - DeLayre, Jean L.

AU - Ingwall, Joanne S.

AU - Malloy, Craig

AU - Fossel, Eric T.

PY - 1981

Y1 - 1981

N2 - Sodium-23 nuclear magnetic resonance images of phantoms and gated images of isolated perfused working rat hearts were obtained. By synchronizing the nuclear magnetic resonance process to the heartbeat, images were obtained at systole and at diastole.

AB - Sodium-23 nuclear magnetic resonance images of phantoms and gated images of isolated perfused working rat hearts were obtained. By synchronizing the nuclear magnetic resonance process to the heartbeat, images were obtained at systole and at diastole.

UR - http://www.scopus.com/inward/record.url?scp=0019515355&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0019515355&partnerID=8YFLogxK

M3 - Article

C2 - 7233188

AN - SCOPUS:0019515355

VL - 212

SP - 935

EP - 936

JO - Science

JF - Science

SN - 0036-8075

IS - 4497

ER -