High-resolution phased-array MRI of the human brain at 7 tesla

Initial experience in multiple sclerosis patients

Meredith Metcalf, Duan Xu, Darin T. Okuda, Lucas Carvajal, Radhika Srinivasan, Douglas A C Kelley, Pratik Mukherjee, Sarah J. Nelson, Daniel B. Vigneron, Daniel Pelletier

Research output: Contribution to journalArticle

58 Citations (Scopus)

Abstract

Recent advancement for magnetic resonance imaging (MRI) involves the incorporation of higher-field strengths. Although imagers with higher magnetic field strengths were developed and tested in research labs, the direct application to patient MR studies have been extremely limited. Imaging at 7 Tesla (7T) affords advantages in signal-to-noise ratio and image contrast and resolution; however, these benefits can only be realized if the correct coils exist to capture the images. The objective of this study was to develop optimized high-resolution 7T MRI techniques using high sensitivity, specialized phased-array coils, for improved gray matter (GM) and white matter differentiation, in an effort to improve visualization of multiple sclerosis (MS) lesions in vivo. Twenty-three subjects were enrolled in this preliminary study, 17 with clinically definite MS (11 females, 6 males; mean age 43.4 years; range 22-64 years) and 6 healthy controls (2 females, 4 males; mean age 39.0 years; range 27-67 years). MR imaging of MS patients at 7T was demonstrated to be safe, well tolerated, and provided high-resolution anatomical images allowing visualization of structural abnormalities localized near or within the cortical layers. Clear involvement of the GM was observed with improved morphological detail in comparison to imaging at lower-field strength.

Original languageEnglish (US)
Pages (from-to)141-147
Number of pages7
JournalJournal of Neuroimaging
Volume20
Issue number2
DOIs
StatePublished - 2010

Fingerprint

Multiple Sclerosis
Magnetic Resonance Imaging
Brain
Signal-To-Noise Ratio
Magnetic Fields
Research
Gray Matter
White Matter

Keywords

  • 7T
  • Cortical lesions
  • High-resolution
  • Multiple sclerosis

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Clinical Neurology
  • Medicine(all)

Cite this

High-resolution phased-array MRI of the human brain at 7 tesla : Initial experience in multiple sclerosis patients. / Metcalf, Meredith; Xu, Duan; Okuda, Darin T.; Carvajal, Lucas; Srinivasan, Radhika; Kelley, Douglas A C; Mukherjee, Pratik; Nelson, Sarah J.; Vigneron, Daniel B.; Pelletier, Daniel.

In: Journal of Neuroimaging, Vol. 20, No. 2, 2010, p. 141-147.

Research output: Contribution to journalArticle

Metcalf, M, Xu, D, Okuda, DT, Carvajal, L, Srinivasan, R, Kelley, DAC, Mukherjee, P, Nelson, SJ, Vigneron, DB & Pelletier, D 2010, 'High-resolution phased-array MRI of the human brain at 7 tesla: Initial experience in multiple sclerosis patients', Journal of Neuroimaging, vol. 20, no. 2, pp. 141-147. https://doi.org/10.1111/j.1552-6569.2008.00338.x
Metcalf, Meredith ; Xu, Duan ; Okuda, Darin T. ; Carvajal, Lucas ; Srinivasan, Radhika ; Kelley, Douglas A C ; Mukherjee, Pratik ; Nelson, Sarah J. ; Vigneron, Daniel B. ; Pelletier, Daniel. / High-resolution phased-array MRI of the human brain at 7 tesla : Initial experience in multiple sclerosis patients. In: Journal of Neuroimaging. 2010 ; Vol. 20, No. 2. pp. 141-147.
@article{43b7398bddee4c5196e99527668c436a,
title = "High-resolution phased-array MRI of the human brain at 7 tesla: Initial experience in multiple sclerosis patients",
abstract = "Recent advancement for magnetic resonance imaging (MRI) involves the incorporation of higher-field strengths. Although imagers with higher magnetic field strengths were developed and tested in research labs, the direct application to patient MR studies have been extremely limited. Imaging at 7 Tesla (7T) affords advantages in signal-to-noise ratio and image contrast and resolution; however, these benefits can only be realized if the correct coils exist to capture the images. The objective of this study was to develop optimized high-resolution 7T MRI techniques using high sensitivity, specialized phased-array coils, for improved gray matter (GM) and white matter differentiation, in an effort to improve visualization of multiple sclerosis (MS) lesions in vivo. Twenty-three subjects were enrolled in this preliminary study, 17 with clinically definite MS (11 females, 6 males; mean age 43.4 years; range 22-64 years) and 6 healthy controls (2 females, 4 males; mean age 39.0 years; range 27-67 years). MR imaging of MS patients at 7T was demonstrated to be safe, well tolerated, and provided high-resolution anatomical images allowing visualization of structural abnormalities localized near or within the cortical layers. Clear involvement of the GM was observed with improved morphological detail in comparison to imaging at lower-field strength.",
keywords = "7T, Cortical lesions, High-resolution, Multiple sclerosis",
author = "Meredith Metcalf and Duan Xu and Okuda, {Darin T.} and Lucas Carvajal and Radhika Srinivasan and Kelley, {Douglas A C} and Pratik Mukherjee and Nelson, {Sarah J.} and Vigneron, {Daniel B.} and Daniel Pelletier",
year = "2010",
doi = "10.1111/j.1552-6569.2008.00338.x",
language = "English (US)",
volume = "20",
pages = "141--147",
journal = "Journal of Neuroimaging",
issn = "1051-2284",
publisher = "Wiley-Blackwell",
number = "2",

}

TY - JOUR

T1 - High-resolution phased-array MRI of the human brain at 7 tesla

T2 - Initial experience in multiple sclerosis patients

AU - Metcalf, Meredith

AU - Xu, Duan

AU - Okuda, Darin T.

AU - Carvajal, Lucas

AU - Srinivasan, Radhika

AU - Kelley, Douglas A C

AU - Mukherjee, Pratik

AU - Nelson, Sarah J.

AU - Vigneron, Daniel B.

AU - Pelletier, Daniel

PY - 2010

Y1 - 2010

N2 - Recent advancement for magnetic resonance imaging (MRI) involves the incorporation of higher-field strengths. Although imagers with higher magnetic field strengths were developed and tested in research labs, the direct application to patient MR studies have been extremely limited. Imaging at 7 Tesla (7T) affords advantages in signal-to-noise ratio and image contrast and resolution; however, these benefits can only be realized if the correct coils exist to capture the images. The objective of this study was to develop optimized high-resolution 7T MRI techniques using high sensitivity, specialized phased-array coils, for improved gray matter (GM) and white matter differentiation, in an effort to improve visualization of multiple sclerosis (MS) lesions in vivo. Twenty-three subjects were enrolled in this preliminary study, 17 with clinically definite MS (11 females, 6 males; mean age 43.4 years; range 22-64 years) and 6 healthy controls (2 females, 4 males; mean age 39.0 years; range 27-67 years). MR imaging of MS patients at 7T was demonstrated to be safe, well tolerated, and provided high-resolution anatomical images allowing visualization of structural abnormalities localized near or within the cortical layers. Clear involvement of the GM was observed with improved morphological detail in comparison to imaging at lower-field strength.

AB - Recent advancement for magnetic resonance imaging (MRI) involves the incorporation of higher-field strengths. Although imagers with higher magnetic field strengths were developed and tested in research labs, the direct application to patient MR studies have been extremely limited. Imaging at 7 Tesla (7T) affords advantages in signal-to-noise ratio and image contrast and resolution; however, these benefits can only be realized if the correct coils exist to capture the images. The objective of this study was to develop optimized high-resolution 7T MRI techniques using high sensitivity, specialized phased-array coils, for improved gray matter (GM) and white matter differentiation, in an effort to improve visualization of multiple sclerosis (MS) lesions in vivo. Twenty-three subjects were enrolled in this preliminary study, 17 with clinically definite MS (11 females, 6 males; mean age 43.4 years; range 22-64 years) and 6 healthy controls (2 females, 4 males; mean age 39.0 years; range 27-67 years). MR imaging of MS patients at 7T was demonstrated to be safe, well tolerated, and provided high-resolution anatomical images allowing visualization of structural abnormalities localized near or within the cortical layers. Clear involvement of the GM was observed with improved morphological detail in comparison to imaging at lower-field strength.

KW - 7T

KW - Cortical lesions

KW - High-resolution

KW - Multiple sclerosis

UR - http://www.scopus.com/inward/record.url?scp=77950615315&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77950615315&partnerID=8YFLogxK

U2 - 10.1111/j.1552-6569.2008.00338.x

DO - 10.1111/j.1552-6569.2008.00338.x

M3 - Article

VL - 20

SP - 141

EP - 147

JO - Journal of Neuroimaging

JF - Journal of Neuroimaging

SN - 1051-2284

IS - 2

ER -