TY - JOUR
T1 - Impact of blood cultures drawn by phlebotomy on contamination rates and health care costs in a hospital emergency department
AU - Gander, Rita M.
AU - Byrd, Linda
AU - DeCrescenzo, Michael
AU - Hirany, Shaina
AU - Bowen, Michelle
AU - Baughman, Judy
PY - 2009/4
Y1 - 2009/4
N2 - We conducted a prospective comparison of blood culture contamination rates associated with dedicated phlebotomists and nonphlebotomy staff in the emergency department (ED) at Parkland Memorial Hospital in Dallas, TX. In addition, hospital charges and lengths of stay were determined for patients with negative, false-positive, and true-positive blood culture results. A total of 5,432 blood culture collections from two ED areas, the western wing of the ED (ED west) and the nonwestern wing of the ED (ED nonwest), were evaluated over a 13-month period. Phlebotomists drew 2,012 (55%) of the blood cultures in ED west while nonphlebotomy staff drew 1,650 (45%) in ED west and 1,770 (100%) in ED nonwest. The contamination rates of blood cultures collected by phlebotomists were significantly lower than those collected by nonphlebotomists in ED west (62/2,012 [3.1%] versus 122/1,650 [7.4%]; P <0.001). Similar results were observed when rates between phlebotomists in ED west and nonphlebotomy staff in ED nonwest were compared (62/2,012 [3.1%] versus 100/1,770 [5.6%]; P < 0.001). Comparison of median patient charges between negative and false-positive episodes ($18,752 versus $27,472) showed $8,720 in additional charges per contamination event while the median length of stay increased marginally from 4 to 5 days. By utilizing phlebotomists to collect blood cultures in the ED, contamination rates were lowered to recommended levels, with projected reductions in patient charges of approximately $4.1 million per year. Copyright
AB - We conducted a prospective comparison of blood culture contamination rates associated with dedicated phlebotomists and nonphlebotomy staff in the emergency department (ED) at Parkland Memorial Hospital in Dallas, TX. In addition, hospital charges and lengths of stay were determined for patients with negative, false-positive, and true-positive blood culture results. A total of 5,432 blood culture collections from two ED areas, the western wing of the ED (ED west) and the nonwestern wing of the ED (ED nonwest), were evaluated over a 13-month period. Phlebotomists drew 2,012 (55%) of the blood cultures in ED west while nonphlebotomy staff drew 1,650 (45%) in ED west and 1,770 (100%) in ED nonwest. The contamination rates of blood cultures collected by phlebotomists were significantly lower than those collected by nonphlebotomists in ED west (62/2,012 [3.1%] versus 122/1,650 [7.4%]; P <0.001). Similar results were observed when rates between phlebotomists in ED west and nonphlebotomy staff in ED nonwest were compared (62/2,012 [3.1%] versus 100/1,770 [5.6%]; P < 0.001). Comparison of median patient charges between negative and false-positive episodes ($18,752 versus $27,472) showed $8,720 in additional charges per contamination event while the median length of stay increased marginally from 4 to 5 days. By utilizing phlebotomists to collect blood cultures in the ED, contamination rates were lowered to recommended levels, with projected reductions in patient charges of approximately $4.1 million per year. Copyright
UR - http://www.scopus.com/inward/record.url?scp=65249123059&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=65249123059&partnerID=8YFLogxK
U2 - 10.1128/JCM.02162-08
DO - 10.1128/JCM.02162-08
M3 - Article
C2 - 19171686
AN - SCOPUS:65249123059
SN - 0095-1137
VL - 47
SP - 1021
EP - 1024
JO - Journal of Clinical Microbiology
JF - Journal of Clinical Microbiology
IS - 4
ER -