T1 - Impact of colorized display of mammograms on lesion detection
AU - Knippa, Emily E.
AU - Berg, Erica
AU - Richard, Samuel
AU - Lin, Yuan
AU - Choudhury, Kingshuk Roy
AU - Samei, Ehsan
AU - Baker, Jay A.
N1 - Publisher Copyright:
© Society of Breast Imaging 2019.
PY - 2020
Y1 - 2020
N2 - Objective: To assess the effect of the colorized display of digital mammograms on observer detection of subtle breast lesions. Methods: Three separate observer studies compared detection performance using grayscale versus color display of 1) low-contrast mass-like objects in a standardized mammography phantom; 2) simulated microcalcifications in a background of normal breast parenchyma; and 3) standard-of-care clinical digital mammograms with subtle calcifications and masses. Colorization of the images was done by displaying each image pixel in blue, green, and red hues, or gray, maintaining DICOM-calibrated luminance scale and consistent luminance range. For the simulated calcifications and clinical mammogram studies, comparison of detection rates was computed using McNemar's test for paired differences. Results: For the phantom study, mass-like object detection was significantly better using a green colormap than grayscale (73.3% vs 70.8%, P = .009), with no significant improvement using blue or red colormaps (72.6% and 72.5%, respectively). For simulated microcalcifications, no significant difference was noted in detection using the green colormap, as compared with grayscale. For clinical digital screening mammograms, no significant difference was noted between gray and green colormaps for detection of microcalcifications. Green color display, however, resulted in decreased sensitivity for detection of subtle masses (63% vs 69%, P = .03). Conclusion: Although modest improvement was demonstrated for a detection task using colorized display of a standard mammography phantom, no significant improvement was demonstrated using a color display for a simulated clinical detection task, and actual clinical performance was worse for colorized display of mammograms in comparison to standard grayscale display.
AB - Objective: To assess the effect of the colorized display of digital mammograms on observer detection of subtle breast lesions. Methods: Three separate observer studies compared detection performance using grayscale versus color display of 1) low-contrast mass-like objects in a standardized mammography phantom; 2) simulated microcalcifications in a background of normal breast parenchyma; and 3) standard-of-care clinical digital mammograms with subtle calcifications and masses. Colorization of the images was done by displaying each image pixel in blue, green, and red hues, or gray, maintaining DICOM-calibrated luminance scale and consistent luminance range. For the simulated calcifications and clinical mammogram studies, comparison of detection rates was computed using McNemar's test for paired differences. Results: For the phantom study, mass-like object detection was significantly better using a green colormap than grayscale (73.3% vs 70.8%, P = .009), with no significant improvement using blue or red colormaps (72.6% and 72.5%, respectively). For simulated microcalcifications, no significant difference was noted in detection using the green colormap, as compared with grayscale. For clinical digital screening mammograms, no significant difference was noted between gray and green colormaps for detection of microcalcifications. Green color display, however, resulted in decreased sensitivity for detection of subtle masses (63% vs 69%, P = .03). Conclusion: Although modest improvement was demonstrated for a detection task using colorized display of a standard mammography phantom, no significant improvement was demonstrated using a color display for a simulated clinical detection task, and actual clinical performance was worse for colorized display of mammograms in comparison to standard grayscale display.
KW - Color display
KW - Mammography
KW - Phantom
UR - http://www.scopus.com/inward/record.url?scp=85121503344&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85121503344&partnerID=8YFLogxK
U2 - 10.1093/JBI/WBZ075
DO - 10.1093/JBI/WBZ075
M3 - Article
AN - SCOPUS:85121503344
SN - 2631-6110
VL - 2
SP - 22
EP - 28
JO - Journal of Breast Imaging
JF - Journal of Breast Imaging
IS - 1
ER -