Abstract

A novel, cylindrical geometry, superconducting pion channel has been constructed at Stanford. It can simultaneously deliver up to 60 radially converging pion beams of the same mean momentum but with individually variable momentum spread (0.0-4.3%). Virtually no tuning of the pion beam is required. Preliminary tests have demonstrated many of the performance characteristics which facilitate the treatment of selected human tumors.

Original languageEnglish (US)
Pages (from-to)527-529
Number of pages3
JournalRadiology
Volume122
Issue number2
StatePublished - 1977

Fingerprint

Mesons
Neoplasms

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Pistenma, D. A., Fessenden, P., Boyd, D. P., Luxton, G., Taber, R., & Bagshaw, M. A. (1977). Initial performance of the Stanford medical pion generator. Radiology, 122(2), 527-529.

Initial performance of the Stanford medical pion generator. / Pistenma, D. A.; Fessenden, P.; Boyd, D. P.; Luxton, G.; Taber, R.; Bagshaw, M. A.

In: Radiology, Vol. 122, No. 2, 1977, p. 527-529.

Research output: Contribution to journalArticle

Pistenma, DA, Fessenden, P, Boyd, DP, Luxton, G, Taber, R & Bagshaw, MA 1977, 'Initial performance of the Stanford medical pion generator', Radiology, vol. 122, no. 2, pp. 527-529.
Pistenma DA, Fessenden P, Boyd DP, Luxton G, Taber R, Bagshaw MA. Initial performance of the Stanford medical pion generator. Radiology. 1977;122(2):527-529.
Pistenma, D. A. ; Fessenden, P. ; Boyd, D. P. ; Luxton, G. ; Taber, R. ; Bagshaw, M. A. / Initial performance of the Stanford medical pion generator. In: Radiology. 1977 ; Vol. 122, No. 2. pp. 527-529.
@article{38fbd7b8e7d24810969fee9307b6a8c2,
title = "Initial performance of the Stanford medical pion generator",
abstract = "A novel, cylindrical geometry, superconducting pion channel has been constructed at Stanford. It can simultaneously deliver up to 60 radially converging pion beams of the same mean momentum but with individually variable momentum spread (0.0-4.3{\%}). Virtually no tuning of the pion beam is required. Preliminary tests have demonstrated many of the performance characteristics which facilitate the treatment of selected human tumors.",
author = "Pistenma, {D. A.} and P. Fessenden and Boyd, {D. P.} and G. Luxton and R. Taber and Bagshaw, {M. A.}",
year = "1977",
language = "English (US)",
volume = "122",
pages = "527--529",
journal = "Radiology",
issn = "0033-8419",
publisher = "Radiological Society of North America Inc.",
number = "2",

}

TY - JOUR

T1 - Initial performance of the Stanford medical pion generator

AU - Pistenma, D. A.

AU - Fessenden, P.

AU - Boyd, D. P.

AU - Luxton, G.

AU - Taber, R.

AU - Bagshaw, M. A.

PY - 1977

Y1 - 1977

N2 - A novel, cylindrical geometry, superconducting pion channel has been constructed at Stanford. It can simultaneously deliver up to 60 radially converging pion beams of the same mean momentum but with individually variable momentum spread (0.0-4.3%). Virtually no tuning of the pion beam is required. Preliminary tests have demonstrated many of the performance characteristics which facilitate the treatment of selected human tumors.

AB - A novel, cylindrical geometry, superconducting pion channel has been constructed at Stanford. It can simultaneously deliver up to 60 radially converging pion beams of the same mean momentum but with individually variable momentum spread (0.0-4.3%). Virtually no tuning of the pion beam is required. Preliminary tests have demonstrated many of the performance characteristics which facilitate the treatment of selected human tumors.

UR - http://www.scopus.com/inward/record.url?scp=0017364760&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0017364760&partnerID=8YFLogxK

M3 - Article

C2 - 834908

AN - SCOPUS:0017364760

VL - 122

SP - 527

EP - 529

JO - Radiology

JF - Radiology

SN - 0033-8419

IS - 2

ER -