Iterative image reconstruction for CBCT using edge-preserving prior

Jing Wang, Tianfang Li, Lei Xing

Research output: Contribution to journalArticle

132 Citations (Scopus)

Abstract

On-board cone-beam computed tomography (CBCT) is a new imaging technique for radiation therapy guidance, which provides volumetric information of a patient at treatment position. CBCT improves the setup accuracy and may be used for dose reconstruction. However, there is great concern that the repeated use of CBCT during a treatment course delivers too much of an extra dose to the patient. To reduce the CBCT dose, one needs to lower the total mAs of the x-ray tube current, which usually leads to reduced image quality. Our goal of this work is to develop an effective method that enables one to achieve a clinically acceptable CBCT image with as low as possible mAs without compromising quality. An iterative image reconstruction algorithm based on a penalized weighted least-squares (PWLS) principle was developed for this purpose. To preserve edges in the reconstructed images, we designed an anisotropic penalty term of a quadratic form. The algorithm was evaluated with a CT quality assurance phantom and an anthropomorphic head phantom. Compared with conventional isotropic penalty, the PWLS image reconstruction algorithm with anisotropic penalty shows better resolution preservation.

Original languageEnglish (US)
Pages (from-to)252-260
Number of pages9
JournalMedical Physics
Volume36
Issue number1
DOIs
StatePublished - 2009

Fingerprint

Cone-Beam Computed Tomography
Computer-Assisted Image Processing
Least-Squares Analysis
Radiotherapy
Head
X-Rays
Therapeutics

Keywords

  • Cone-beam CT
  • Edge-preserving penalty
  • Iterative reconstruction
  • Low-dose
  • PWLS

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

Iterative image reconstruction for CBCT using edge-preserving prior. / Wang, Jing; Li, Tianfang; Xing, Lei.

In: Medical Physics, Vol. 36, No. 1, 2009, p. 252-260.

Research output: Contribution to journalArticle

Wang, Jing ; Li, Tianfang ; Xing, Lei. / Iterative image reconstruction for CBCT using edge-preserving prior. In: Medical Physics. 2009 ; Vol. 36, No. 1. pp. 252-260.
@article{4ea1cc0557cc44f394cb083201b449e0,
title = "Iterative image reconstruction for CBCT using edge-preserving prior",
abstract = "On-board cone-beam computed tomography (CBCT) is a new imaging technique for radiation therapy guidance, which provides volumetric information of a patient at treatment position. CBCT improves the setup accuracy and may be used for dose reconstruction. However, there is great concern that the repeated use of CBCT during a treatment course delivers too much of an extra dose to the patient. To reduce the CBCT dose, one needs to lower the total mAs of the x-ray tube current, which usually leads to reduced image quality. Our goal of this work is to develop an effective method that enables one to achieve a clinically acceptable CBCT image with as low as possible mAs without compromising quality. An iterative image reconstruction algorithm based on a penalized weighted least-squares (PWLS) principle was developed for this purpose. To preserve edges in the reconstructed images, we designed an anisotropic penalty term of a quadratic form. The algorithm was evaluated with a CT quality assurance phantom and an anthropomorphic head phantom. Compared with conventional isotropic penalty, the PWLS image reconstruction algorithm with anisotropic penalty shows better resolution preservation.",
keywords = "Cone-beam CT, Edge-preserving penalty, Iterative reconstruction, Low-dose, PWLS",
author = "Jing Wang and Tianfang Li and Lei Xing",
year = "2009",
doi = "10.1118/1.3036112",
language = "English (US)",
volume = "36",
pages = "252--260",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "1",

}

TY - JOUR

T1 - Iterative image reconstruction for CBCT using edge-preserving prior

AU - Wang, Jing

AU - Li, Tianfang

AU - Xing, Lei

PY - 2009

Y1 - 2009

N2 - On-board cone-beam computed tomography (CBCT) is a new imaging technique for radiation therapy guidance, which provides volumetric information of a patient at treatment position. CBCT improves the setup accuracy and may be used for dose reconstruction. However, there is great concern that the repeated use of CBCT during a treatment course delivers too much of an extra dose to the patient. To reduce the CBCT dose, one needs to lower the total mAs of the x-ray tube current, which usually leads to reduced image quality. Our goal of this work is to develop an effective method that enables one to achieve a clinically acceptable CBCT image with as low as possible mAs without compromising quality. An iterative image reconstruction algorithm based on a penalized weighted least-squares (PWLS) principle was developed for this purpose. To preserve edges in the reconstructed images, we designed an anisotropic penalty term of a quadratic form. The algorithm was evaluated with a CT quality assurance phantom and an anthropomorphic head phantom. Compared with conventional isotropic penalty, the PWLS image reconstruction algorithm with anisotropic penalty shows better resolution preservation.

AB - On-board cone-beam computed tomography (CBCT) is a new imaging technique for radiation therapy guidance, which provides volumetric information of a patient at treatment position. CBCT improves the setup accuracy and may be used for dose reconstruction. However, there is great concern that the repeated use of CBCT during a treatment course delivers too much of an extra dose to the patient. To reduce the CBCT dose, one needs to lower the total mAs of the x-ray tube current, which usually leads to reduced image quality. Our goal of this work is to develop an effective method that enables one to achieve a clinically acceptable CBCT image with as low as possible mAs without compromising quality. An iterative image reconstruction algorithm based on a penalized weighted least-squares (PWLS) principle was developed for this purpose. To preserve edges in the reconstructed images, we designed an anisotropic penalty term of a quadratic form. The algorithm was evaluated with a CT quality assurance phantom and an anthropomorphic head phantom. Compared with conventional isotropic penalty, the PWLS image reconstruction algorithm with anisotropic penalty shows better resolution preservation.

KW - Cone-beam CT

KW - Edge-preserving penalty

KW - Iterative reconstruction

KW - Low-dose

KW - PWLS

UR - http://www.scopus.com/inward/record.url?scp=58149141914&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=58149141914&partnerID=8YFLogxK

U2 - 10.1118/1.3036112

DO - 10.1118/1.3036112

M3 - Article

VL - 36

SP - 252

EP - 260

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 1

ER -