Low dose pedal magnetic resonance angiography at 3 tesla with time-resolved imaging of contrast kinetics: A feasibility study

Suvranu Ganguli, Ivan Pedrosa, Martin P. Smith, Eric R. Niendorf, Scott Fredericks, Neil M. Rofsky

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

Objectives: To assess the feasibility of low-dose time-resolved imaging of contrast kinetics (TRICKS) magnetic resonance (MR) angiography of the pedal vasculature at 3.0 Tesla (T) using a head coil. Materials and methods: Eleven healthy volunteers were imaged using TRICKS MR angiography at 3.0 T with both feet positioned in a head coil. A dose of 7 mL was used for each of 3 acquisitions: images were obtained of each foot in the sagittal plane, and then both feet were imaged simultaneously in the transverse plane. The following parameters were used for acquisition: (TR/TE 4.7 milliseconds/ 1.3 milliseconds, field of view ≤ 28 cm, Flip angle ≤ 30 degrees, 384 ×256 matrix, section thickness ≤ 1.6 mm, Bandwidth ≤ 19.23). The dorsalis pedis, plantar arch, distal posterior tibial, lateral tarsal, and medial plantar arteries were graded for visualization, artifact, and overall image quality on a 4-point scale (1 ≤ worst; 4 ≤ best). Results: Superior visualization trended towards separate sagittal acquisitions when compared with that of bilateral transverse acquisitions for most of the individual vessels of the foot. Overall, separate sagittal acquisitions (average score ≤ 2.9) were superior to bilateral transverse acquisitions (average score ≤ 2.6). The average image quality score reflecting the amount of artifact was 2.6 for studies obtained using bilateral transverse acquisitions and 3.1 for studies obtained using separate sagittal acquisitions. Conclusion: Low-dose gadolinium multi-injection TRICKS and bolus-chase MR angiography at 3.0 T provides an effective and easily reproducible technique for imaging of the pedal vasculature in volunteers and has great potential for clinical application.

Original languageEnglish (US)
Pages (from-to)650-655
Number of pages6
JournalInvestigative Radiology
Volume43
Issue number9
DOIs
StatePublished - Sep 2008

Fingerprint

Magnetic Resonance Angiography
Feasibility Studies
Foot
Artifacts
Head
Gadolinium
Volunteers
Healthy Volunteers
Arteries
Injections

Keywords

  • 3 Tesla
  • MR angiography
  • Pedal angiographic imaging
  • Pedal vasculature
  • Time-resolved imaging of contrast kinetics (TRICKS)

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Low dose pedal magnetic resonance angiography at 3 tesla with time-resolved imaging of contrast kinetics : A feasibility study. / Ganguli, Suvranu; Pedrosa, Ivan; Smith, Martin P.; Niendorf, Eric R.; Fredericks, Scott; Rofsky, Neil M.

In: Investigative Radiology, Vol. 43, No. 9, 09.2008, p. 650-655.

Research output: Contribution to journalArticle

@article{91b1a32dbaa643b1a6ce51603c03edb6,
title = "Low dose pedal magnetic resonance angiography at 3 tesla with time-resolved imaging of contrast kinetics: A feasibility study",
abstract = "Objectives: To assess the feasibility of low-dose time-resolved imaging of contrast kinetics (TRICKS) magnetic resonance (MR) angiography of the pedal vasculature at 3.0 Tesla (T) using a head coil. Materials and methods: Eleven healthy volunteers were imaged using TRICKS MR angiography at 3.0 T with both feet positioned in a head coil. A dose of 7 mL was used for each of 3 acquisitions: images were obtained of each foot in the sagittal plane, and then both feet were imaged simultaneously in the transverse plane. The following parameters were used for acquisition: (TR/TE 4.7 milliseconds/ 1.3 milliseconds, field of view ≤ 28 cm, Flip angle ≤ 30 degrees, 384 ×256 matrix, section thickness ≤ 1.6 mm, Bandwidth ≤ 19.23). The dorsalis pedis, plantar arch, distal posterior tibial, lateral tarsal, and medial plantar arteries were graded for visualization, artifact, and overall image quality on a 4-point scale (1 ≤ worst; 4 ≤ best). Results: Superior visualization trended towards separate sagittal acquisitions when compared with that of bilateral transverse acquisitions for most of the individual vessels of the foot. Overall, separate sagittal acquisitions (average score ≤ 2.9) were superior to bilateral transverse acquisitions (average score ≤ 2.6). The average image quality score reflecting the amount of artifact was 2.6 for studies obtained using bilateral transverse acquisitions and 3.1 for studies obtained using separate sagittal acquisitions. Conclusion: Low-dose gadolinium multi-injection TRICKS and bolus-chase MR angiography at 3.0 T provides an effective and easily reproducible technique for imaging of the pedal vasculature in volunteers and has great potential for clinical application.",
keywords = "3 Tesla, MR angiography, Pedal angiographic imaging, Pedal vasculature, Time-resolved imaging of contrast kinetics (TRICKS)",
author = "Suvranu Ganguli and Ivan Pedrosa and Smith, {Martin P.} and Niendorf, {Eric R.} and Scott Fredericks and Rofsky, {Neil M.}",
year = "2008",
month = "9",
doi = "10.1097/RLI.0b013e31817ed1e3",
language = "English (US)",
volume = "43",
pages = "650--655",
journal = "Investigative Radiology",
issn = "0020-9996",
publisher = "Lippincott Williams and Wilkins",
number = "9",

}

TY - JOUR

T1 - Low dose pedal magnetic resonance angiography at 3 tesla with time-resolved imaging of contrast kinetics

T2 - A feasibility study

AU - Ganguli, Suvranu

AU - Pedrosa, Ivan

AU - Smith, Martin P.

AU - Niendorf, Eric R.

AU - Fredericks, Scott

AU - Rofsky, Neil M.

PY - 2008/9

Y1 - 2008/9

N2 - Objectives: To assess the feasibility of low-dose time-resolved imaging of contrast kinetics (TRICKS) magnetic resonance (MR) angiography of the pedal vasculature at 3.0 Tesla (T) using a head coil. Materials and methods: Eleven healthy volunteers were imaged using TRICKS MR angiography at 3.0 T with both feet positioned in a head coil. A dose of 7 mL was used for each of 3 acquisitions: images were obtained of each foot in the sagittal plane, and then both feet were imaged simultaneously in the transverse plane. The following parameters were used for acquisition: (TR/TE 4.7 milliseconds/ 1.3 milliseconds, field of view ≤ 28 cm, Flip angle ≤ 30 degrees, 384 ×256 matrix, section thickness ≤ 1.6 mm, Bandwidth ≤ 19.23). The dorsalis pedis, plantar arch, distal posterior tibial, lateral tarsal, and medial plantar arteries were graded for visualization, artifact, and overall image quality on a 4-point scale (1 ≤ worst; 4 ≤ best). Results: Superior visualization trended towards separate sagittal acquisitions when compared with that of bilateral transverse acquisitions for most of the individual vessels of the foot. Overall, separate sagittal acquisitions (average score ≤ 2.9) were superior to bilateral transverse acquisitions (average score ≤ 2.6). The average image quality score reflecting the amount of artifact was 2.6 for studies obtained using bilateral transverse acquisitions and 3.1 for studies obtained using separate sagittal acquisitions. Conclusion: Low-dose gadolinium multi-injection TRICKS and bolus-chase MR angiography at 3.0 T provides an effective and easily reproducible technique for imaging of the pedal vasculature in volunteers and has great potential for clinical application.

AB - Objectives: To assess the feasibility of low-dose time-resolved imaging of contrast kinetics (TRICKS) magnetic resonance (MR) angiography of the pedal vasculature at 3.0 Tesla (T) using a head coil. Materials and methods: Eleven healthy volunteers were imaged using TRICKS MR angiography at 3.0 T with both feet positioned in a head coil. A dose of 7 mL was used for each of 3 acquisitions: images were obtained of each foot in the sagittal plane, and then both feet were imaged simultaneously in the transverse plane. The following parameters were used for acquisition: (TR/TE 4.7 milliseconds/ 1.3 milliseconds, field of view ≤ 28 cm, Flip angle ≤ 30 degrees, 384 ×256 matrix, section thickness ≤ 1.6 mm, Bandwidth ≤ 19.23). The dorsalis pedis, plantar arch, distal posterior tibial, lateral tarsal, and medial plantar arteries were graded for visualization, artifact, and overall image quality on a 4-point scale (1 ≤ worst; 4 ≤ best). Results: Superior visualization trended towards separate sagittal acquisitions when compared with that of bilateral transverse acquisitions for most of the individual vessels of the foot. Overall, separate sagittal acquisitions (average score ≤ 2.9) were superior to bilateral transverse acquisitions (average score ≤ 2.6). The average image quality score reflecting the amount of artifact was 2.6 for studies obtained using bilateral transverse acquisitions and 3.1 for studies obtained using separate sagittal acquisitions. Conclusion: Low-dose gadolinium multi-injection TRICKS and bolus-chase MR angiography at 3.0 T provides an effective and easily reproducible technique for imaging of the pedal vasculature in volunteers and has great potential for clinical application.

KW - 3 Tesla

KW - MR angiography

KW - Pedal angiographic imaging

KW - Pedal vasculature

KW - Time-resolved imaging of contrast kinetics (TRICKS)

UR - http://www.scopus.com/inward/record.url?scp=55249118688&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=55249118688&partnerID=8YFLogxK

U2 - 10.1097/RLI.0b013e31817ed1e3

DO - 10.1097/RLI.0b013e31817ed1e3

M3 - Article

C2 - 18708859

AN - SCOPUS:55249118688

VL - 43

SP - 650

EP - 655

JO - Investigative Radiology

JF - Investigative Radiology

SN - 0020-9996

IS - 9

ER -