Magnetization spoiling in radial FLASH contrast-enhanced MR digital subtraction angiography

Parmede Vakil, Sameer A. Ansari, Michael C. Hurley, Himanshu Bhat, H. Hunt Batjer, Bernard R. Bendok, Christopher S. Eddleman, Timothy J. Carroll

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

Purpose: To increase the in-plane spatial resolution and image update rates of 2D magnetic resonance (MR) digital subtraction angiography (DSA) pulse sequences to 0.57 × 0.57 mm and 6 frames/sec, respectively, for intracranial vascular disease applications by developing a radial FLASH protocol and to characterize a new artifact, not previously described in the literature, which arises in the presence of such pulse sequences. Materials and Methods: The pulse sequence was optimized and artifacts were characterized using simulation and phantom studies. With Institutional Review Board (IRB) approval, the pulse sequence was used to acquire time-resolved images from healthy human volunteers and patients with x-ray DSA-confirmed intracranial vascular disease. Results: Artifacts were shown to derive from inhomogeneous spoiling due to the nature of radial waveforms. Gradient spoiling strategies were proposed to eliminate the observed artifact by balancing gradient moments across TR intervals. The resulting radial 2D MR DSA sequence (2.6 sec temporal footprint, 6 frames/sec with sliding window factor 16, 0.57 × 0.57 mm in-plane) demonstrated small vessel detail and corroborated x-ray DSA findings in intracranial vascular imaging studies. Conclusion: Appropriate gradient spoiling in radial 2D MR DSA pulse sequences improves intracranial vascular depiction by eliminating circular banding artifacts. The proposed pulse sequence may provide a useful addition to clinically applied 2D MR DSA scans.

Original languageEnglish (US)
Pages (from-to)249-258
Number of pages10
JournalJournal of Magnetic Resonance Imaging
Volume36
Issue number1
DOIs
StatePublished - Jul 2012

Fingerprint

Digital Subtraction Angiography
Magnetic Resonance Angiography
Artifacts
Cerebrovascular Disorders
Blood Vessels
X-Rays
Research Ethics Committees
Healthy Volunteers

Keywords

  • MR DSA
  • radial imaging
  • spoiling
  • view ordering

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Magnetization spoiling in radial FLASH contrast-enhanced MR digital subtraction angiography. / Vakil, Parmede; Ansari, Sameer A.; Hurley, Michael C.; Bhat, Himanshu; Batjer, H. Hunt; Bendok, Bernard R.; Eddleman, Christopher S.; Carroll, Timothy J.

In: Journal of Magnetic Resonance Imaging, Vol. 36, No. 1, 07.2012, p. 249-258.

Research output: Contribution to journalArticle

Vakil, P, Ansari, SA, Hurley, MC, Bhat, H, Batjer, HH, Bendok, BR, Eddleman, CS & Carroll, TJ 2012, 'Magnetization spoiling in radial FLASH contrast-enhanced MR digital subtraction angiography', Journal of Magnetic Resonance Imaging, vol. 36, no. 1, pp. 249-258. https://doi.org/10.1002/jmri.23630
Vakil, Parmede ; Ansari, Sameer A. ; Hurley, Michael C. ; Bhat, Himanshu ; Batjer, H. Hunt ; Bendok, Bernard R. ; Eddleman, Christopher S. ; Carroll, Timothy J. / Magnetization spoiling in radial FLASH contrast-enhanced MR digital subtraction angiography. In: Journal of Magnetic Resonance Imaging. 2012 ; Vol. 36, No. 1. pp. 249-258.
@article{feafde68802e4300a7330867261b8f45,
title = "Magnetization spoiling in radial FLASH contrast-enhanced MR digital subtraction angiography",
abstract = "Purpose: To increase the in-plane spatial resolution and image update rates of 2D magnetic resonance (MR) digital subtraction angiography (DSA) pulse sequences to 0.57 × 0.57 mm and 6 frames/sec, respectively, for intracranial vascular disease applications by developing a radial FLASH protocol and to characterize a new artifact, not previously described in the literature, which arises in the presence of such pulse sequences. Materials and Methods: The pulse sequence was optimized and artifacts were characterized using simulation and phantom studies. With Institutional Review Board (IRB) approval, the pulse sequence was used to acquire time-resolved images from healthy human volunteers and patients with x-ray DSA-confirmed intracranial vascular disease. Results: Artifacts were shown to derive from inhomogeneous spoiling due to the nature of radial waveforms. Gradient spoiling strategies were proposed to eliminate the observed artifact by balancing gradient moments across TR intervals. The resulting radial 2D MR DSA sequence (2.6 sec temporal footprint, 6 frames/sec with sliding window factor 16, 0.57 × 0.57 mm in-plane) demonstrated small vessel detail and corroborated x-ray DSA findings in intracranial vascular imaging studies. Conclusion: Appropriate gradient spoiling in radial 2D MR DSA pulse sequences improves intracranial vascular depiction by eliminating circular banding artifacts. The proposed pulse sequence may provide a useful addition to clinically applied 2D MR DSA scans.",
keywords = "MR DSA, radial imaging, spoiling, view ordering",
author = "Parmede Vakil and Ansari, {Sameer A.} and Hurley, {Michael C.} and Himanshu Bhat and Batjer, {H. Hunt} and Bendok, {Bernard R.} and Eddleman, {Christopher S.} and Carroll, {Timothy J.}",
year = "2012",
month = "7",
doi = "10.1002/jmri.23630",
language = "English (US)",
volume = "36",
pages = "249--258",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - Magnetization spoiling in radial FLASH contrast-enhanced MR digital subtraction angiography

AU - Vakil, Parmede

AU - Ansari, Sameer A.

AU - Hurley, Michael C.

AU - Bhat, Himanshu

AU - Batjer, H. Hunt

AU - Bendok, Bernard R.

AU - Eddleman, Christopher S.

AU - Carroll, Timothy J.

PY - 2012/7

Y1 - 2012/7

N2 - Purpose: To increase the in-plane spatial resolution and image update rates of 2D magnetic resonance (MR) digital subtraction angiography (DSA) pulse sequences to 0.57 × 0.57 mm and 6 frames/sec, respectively, for intracranial vascular disease applications by developing a radial FLASH protocol and to characterize a new artifact, not previously described in the literature, which arises in the presence of such pulse sequences. Materials and Methods: The pulse sequence was optimized and artifacts were characterized using simulation and phantom studies. With Institutional Review Board (IRB) approval, the pulse sequence was used to acquire time-resolved images from healthy human volunteers and patients with x-ray DSA-confirmed intracranial vascular disease. Results: Artifacts were shown to derive from inhomogeneous spoiling due to the nature of radial waveforms. Gradient spoiling strategies were proposed to eliminate the observed artifact by balancing gradient moments across TR intervals. The resulting radial 2D MR DSA sequence (2.6 sec temporal footprint, 6 frames/sec with sliding window factor 16, 0.57 × 0.57 mm in-plane) demonstrated small vessel detail and corroborated x-ray DSA findings in intracranial vascular imaging studies. Conclusion: Appropriate gradient spoiling in radial 2D MR DSA pulse sequences improves intracranial vascular depiction by eliminating circular banding artifacts. The proposed pulse sequence may provide a useful addition to clinically applied 2D MR DSA scans.

AB - Purpose: To increase the in-plane spatial resolution and image update rates of 2D magnetic resonance (MR) digital subtraction angiography (DSA) pulse sequences to 0.57 × 0.57 mm and 6 frames/sec, respectively, for intracranial vascular disease applications by developing a radial FLASH protocol and to characterize a new artifact, not previously described in the literature, which arises in the presence of such pulse sequences. Materials and Methods: The pulse sequence was optimized and artifacts were characterized using simulation and phantom studies. With Institutional Review Board (IRB) approval, the pulse sequence was used to acquire time-resolved images from healthy human volunteers and patients with x-ray DSA-confirmed intracranial vascular disease. Results: Artifacts were shown to derive from inhomogeneous spoiling due to the nature of radial waveforms. Gradient spoiling strategies were proposed to eliminate the observed artifact by balancing gradient moments across TR intervals. The resulting radial 2D MR DSA sequence (2.6 sec temporal footprint, 6 frames/sec with sliding window factor 16, 0.57 × 0.57 mm in-plane) demonstrated small vessel detail and corroborated x-ray DSA findings in intracranial vascular imaging studies. Conclusion: Appropriate gradient spoiling in radial 2D MR DSA pulse sequences improves intracranial vascular depiction by eliminating circular banding artifacts. The proposed pulse sequence may provide a useful addition to clinically applied 2D MR DSA scans.

KW - MR DSA

KW - radial imaging

KW - spoiling

KW - view ordering

UR - http://www.scopus.com/inward/record.url?scp=84862736614&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84862736614&partnerID=8YFLogxK

U2 - 10.1002/jmri.23630

DO - 10.1002/jmri.23630

M3 - Article

VL - 36

SP - 249

EP - 258

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 1

ER -