Maximal Wall Thickness Measurement in Hypertrophic Cardiomyopathy: Biomarker Variability and its Impact on Clinical Care

Gabriella Captur, Charlotte H. Manisty, Betty Raman, Alberto Marchi, Timothy C. Wong, Rina Ariga, Anish Bhuva, Elizabeth Ormondroyd, Ilaria Lobascio, Claudia Camaioni, Savvas Loizos, Jenade Bonsu-Ofori, Aslan Turer, Vlad G. Zaha, João B. Augutsto, Rhodri H. Davies, Andrew J. Taylor, Arthur Nasis, Mouaz H. Al-Mallah, Sinitsyn ValentinDiego Perez de Arenaza, Vimal Patel, Mark Westwood, Steffen E. Petersen, Chunming Li, Lijun Tang, Shiro Nakamori, Reza Nezafat, Raymond Y. Kwong, Carolyn Y. Ho, Alan G. Fraser, Hugh Watkins, Perry M. Elliott, Stefan Neubauer, Guy Lloyd, Iacopo Olivotto, Petros Nihoyannopoulos, James C. Moon

Research output: Contribution to journalArticlepeer-review

16 Scopus citations

Abstract

Objectives: The aim of this study was to define the variability of maximal wall thickness (MWT) measurements across modalities and predict its impact on care in patients with hypertrophic cardiomyopathy (HCM). Background: Left ventricular MWT measured by echocardiography or cardiovascular magnetic resonance (CMR) contributes to the diagnosis of HCM, stratifies risk, and guides key decisions, including whether to place an implantable cardioverter-defibrillator (ICD). Methods: A 20-center global network provided paired echocardiographic and CMR data sets from patients with HCM, from which 17 paired data sets of the highest quality were selected. These were presented as 7 randomly ordered pairs (at 6 cardiac conferences) to experienced readers who report HCM imaging in their daily practice, and their MWT caliper measurements were captured. The impact of measurement variability on ICD insertion decisions was estimated in 769 separately recruited multicenter patients with HCM using the European Society of Cardiology algorithm for 5-year risk for sudden cardiac death. Results: MWT analysis was completed by 70 readers (from 6 continents; 91% with >5 years’ experience). Seventy-nine percent and 68% scored echocardiographic and CMR image quality as excellent. For both modalities (echocardiographic and then CMR results), intramodality inter-reader MWT percentage variability was large (range –59% to 117% [SD ±20%] and –61% to 52% [SD ±11%], respectively). Agreement between modalities was low (SE of measurement 4.8 mm; 95% CI 4.3 mm-5.2 mm; r = 0.56 [modest correlation]). In the multicenter HCM cohort, this estimated echocardiographic MWT percentage variability (±20%) applied to the European Society of Cardiology algorithm reclassified risk in 19.5% of patients, which would have led to inappropriate ICD decision making in 1 in 7 patients with HCM (8.7% would have had ICD placement recommended despite potential low risk, and 6.8% would not have had ICD placement recommended despite intermediate or high risk). Conclusions: Using the best available images and experienced readers, MWT as a biomarker in HCM has a high degree of inter-reader variability and should be applied with caution as part of decision making for ICD insertion. Better standardization efforts in HCM recommendations by current governing societies are needed to improve clinical decision making in patients with HCM.

Original languageEnglish (US)
Pages (from-to)2123-2134
Number of pages12
JournalJACC: Cardiovascular Imaging
Volume14
Issue number11
DOIs
StatePublished - Nov 2021

Keywords

  • cardiovascular magnetic resonance
  • echocardiography
  • hypertrophic cardiomyopathy
  • wall thickness

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Maximal Wall Thickness Measurement in Hypertrophic Cardiomyopathy: Biomarker Variability and its Impact on Clinical Care'. Together they form a unique fingerprint.

Cite this