Mechanical and microstructural analysis of a radially expandable vascular conduit for neonatal and pediatric cardiovascular surgery

Abigail E. Loneker, Samuel K. Luketich, Doug Bernstein, Arush Kalra, Alan W. Nugent, Antonio D'Amore, Denver M. Faulk

Research output: Contribution to journalArticle

Abstract

In pediatric cardiovascular surgery, there is a significant need for vascular prostheses that have the potential to grow with the patient following implantation. Current clinical options consist of nonexpanding conduits, requiring repeat surgeries as the patient outgrows the device. To address this issue, PECA Labs has developed a novel ePTFE vascular conduit with the capability of being radially expanded via balloon catheterization. In the described study, a systematic characterization and comparison of two proprietary ePTFE expandable conduits was conducted. Conduit sizes of 8 and 16mm inner diameters for both conduits were evaluated before and after expansion with a 26mm balloon. Comprehensive mechanical testing was completed, including quantification of circumferential, and longitudinal tensile strength, suture retention strength, burst strength, water entry pressure, dynamic compliance, and kink radius. Scanning electron microscopy was used to investigate the microstructural properties. Automated extraction of the fiber architectural features for each scanning electron micrograph was achieved with an algorithm for each conduit before and after expansion. Results showed that both conduits were able to expand significantly, to as much as 2.5× their original inner diameter. All mechanical properties were within clinically acceptable values following expansion. Analysis of the microstructure properties of the conduits revealed that the circumferential main angle of orientation, orientation index, and spatial periodicity did not significantly change following expansion, whereas the node area fraction decreased post expansion. Successful proof-of-concept of this novel product represents a critical step toward clinical translation and provides hope for newborns and growing children with congenital heart disease.

Original languageEnglish (US)
JournalJournal of Biomedical Materials Research - Part B Applied Biomaterials
DOIs
StateAccepted/In press - 2017

Fingerprint

Cardiovascular surgery
Pediatrics
Balloons
Mechanical testing
Prosthetics
Surgery
Tensile strength
Scanning
Mechanical properties
Microstructure
Scanning electron microscopy
Electrons
Water
Fibers

Keywords

  • Cardiovascular
  • EPTFE
  • Pediatric surgery
  • Vascular conduit
  • Vascular graft

ASJC Scopus subject areas

  • Biomaterials
  • Biomedical Engineering

Cite this

Mechanical and microstructural analysis of a radially expandable vascular conduit for neonatal and pediatric cardiovascular surgery. / Loneker, Abigail E.; Luketich, Samuel K.; Bernstein, Doug; Kalra, Arush; Nugent, Alan W.; D'Amore, Antonio; Faulk, Denver M.

In: Journal of Biomedical Materials Research - Part B Applied Biomaterials, 2017.

Research output: Contribution to journalArticle

@article{1d574d95c09c4deb91eb17bd78c4514a,
title = "Mechanical and microstructural analysis of a radially expandable vascular conduit for neonatal and pediatric cardiovascular surgery",
abstract = "In pediatric cardiovascular surgery, there is a significant need for vascular prostheses that have the potential to grow with the patient following implantation. Current clinical options consist of nonexpanding conduits, requiring repeat surgeries as the patient outgrows the device. To address this issue, PECA Labs has developed a novel ePTFE vascular conduit with the capability of being radially expanded via balloon catheterization. In the described study, a systematic characterization and comparison of two proprietary ePTFE expandable conduits was conducted. Conduit sizes of 8 and 16mm inner diameters for both conduits were evaluated before and after expansion with a 26mm balloon. Comprehensive mechanical testing was completed, including quantification of circumferential, and longitudinal tensile strength, suture retention strength, burst strength, water entry pressure, dynamic compliance, and kink radius. Scanning electron microscopy was used to investigate the microstructural properties. Automated extraction of the fiber architectural features for each scanning electron micrograph was achieved with an algorithm for each conduit before and after expansion. Results showed that both conduits were able to expand significantly, to as much as 2.5× their original inner diameter. All mechanical properties were within clinically acceptable values following expansion. Analysis of the microstructure properties of the conduits revealed that the circumferential main angle of orientation, orientation index, and spatial periodicity did not significantly change following expansion, whereas the node area fraction decreased post expansion. Successful proof-of-concept of this novel product represents a critical step toward clinical translation and provides hope for newborns and growing children with congenital heart disease.",
keywords = "Cardiovascular, EPTFE, Pediatric surgery, Vascular conduit, Vascular graft",
author = "Loneker, {Abigail E.} and Luketich, {Samuel K.} and Doug Bernstein and Arush Kalra and Nugent, {Alan W.} and Antonio D'Amore and Faulk, {Denver M.}",
year = "2017",
doi = "10.1002/jbm.b.33874",
language = "English (US)",
journal = "Journal of Biomedical Materials Research - Part B Applied Biomaterials",
issn = "1552-4973",
publisher = "John Wiley and Sons Inc.",

}

TY - JOUR

T1 - Mechanical and microstructural analysis of a radially expandable vascular conduit for neonatal and pediatric cardiovascular surgery

AU - Loneker, Abigail E.

AU - Luketich, Samuel K.

AU - Bernstein, Doug

AU - Kalra, Arush

AU - Nugent, Alan W.

AU - D'Amore, Antonio

AU - Faulk, Denver M.

PY - 2017

Y1 - 2017

N2 - In pediatric cardiovascular surgery, there is a significant need for vascular prostheses that have the potential to grow with the patient following implantation. Current clinical options consist of nonexpanding conduits, requiring repeat surgeries as the patient outgrows the device. To address this issue, PECA Labs has developed a novel ePTFE vascular conduit with the capability of being radially expanded via balloon catheterization. In the described study, a systematic characterization and comparison of two proprietary ePTFE expandable conduits was conducted. Conduit sizes of 8 and 16mm inner diameters for both conduits were evaluated before and after expansion with a 26mm balloon. Comprehensive mechanical testing was completed, including quantification of circumferential, and longitudinal tensile strength, suture retention strength, burst strength, water entry pressure, dynamic compliance, and kink radius. Scanning electron microscopy was used to investigate the microstructural properties. Automated extraction of the fiber architectural features for each scanning electron micrograph was achieved with an algorithm for each conduit before and after expansion. Results showed that both conduits were able to expand significantly, to as much as 2.5× their original inner diameter. All mechanical properties were within clinically acceptable values following expansion. Analysis of the microstructure properties of the conduits revealed that the circumferential main angle of orientation, orientation index, and spatial periodicity did not significantly change following expansion, whereas the node area fraction decreased post expansion. Successful proof-of-concept of this novel product represents a critical step toward clinical translation and provides hope for newborns and growing children with congenital heart disease.

AB - In pediatric cardiovascular surgery, there is a significant need for vascular prostheses that have the potential to grow with the patient following implantation. Current clinical options consist of nonexpanding conduits, requiring repeat surgeries as the patient outgrows the device. To address this issue, PECA Labs has developed a novel ePTFE vascular conduit with the capability of being radially expanded via balloon catheterization. In the described study, a systematic characterization and comparison of two proprietary ePTFE expandable conduits was conducted. Conduit sizes of 8 and 16mm inner diameters for both conduits were evaluated before and after expansion with a 26mm balloon. Comprehensive mechanical testing was completed, including quantification of circumferential, and longitudinal tensile strength, suture retention strength, burst strength, water entry pressure, dynamic compliance, and kink radius. Scanning electron microscopy was used to investigate the microstructural properties. Automated extraction of the fiber architectural features for each scanning electron micrograph was achieved with an algorithm for each conduit before and after expansion. Results showed that both conduits were able to expand significantly, to as much as 2.5× their original inner diameter. All mechanical properties were within clinically acceptable values following expansion. Analysis of the microstructure properties of the conduits revealed that the circumferential main angle of orientation, orientation index, and spatial periodicity did not significantly change following expansion, whereas the node area fraction decreased post expansion. Successful proof-of-concept of this novel product represents a critical step toward clinical translation and provides hope for newborns and growing children with congenital heart disease.

KW - Cardiovascular

KW - EPTFE

KW - Pediatric surgery

KW - Vascular conduit

KW - Vascular graft

UR - http://www.scopus.com/inward/record.url?scp=85015219794&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85015219794&partnerID=8YFLogxK

U2 - 10.1002/jbm.b.33874

DO - 10.1002/jbm.b.33874

M3 - Article

JO - Journal of Biomedical Materials Research - Part B Applied Biomaterials

JF - Journal of Biomedical Materials Research - Part B Applied Biomaterials

SN - 1552-4973

ER -