Mechanical characteristics of poly-L-lactic acid absorbable screws and stainless steel screws in basilar osteotomies of the first metatarsal

L. A. Lavery, K. R. Higgins, H. R. Ashry, K. A. Athanasiou

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

The purpose of this study is to evaluate the structural characteristics of 3.5-mm, stainless steel cortical screws and poly-L-lactic acid (PLA) absorbable screws in oblique closing base wedge osteotomies of the first metatarsal. Six pairs of frozen first metatarsal bones were excised from the specimen group. An oblique base wedge osteotomy was performed and fixated with either a 3.5-mm. stainless steel or PLA screw. Specimens were loaded to failure with the Bionix Material Testing System at a constant rate of 0.166 mm./sec. A Student's t test for paired samples with a 95% confidence interval was used to measure differences in ultimate load, ultimate displacement, and structural stiffness. The following results (mean ± standard deviation) were obtained. Structural stiffness, PLA 12.35 ± 3.82 N/mm, and stainless steel 10.13 ± 5.74 N/mm.: ultimate displacement, PLA 7.39 ± 3.23 mm. and stainless steel 10.89 ± 7.91 mm., ultimate load, PLA 57.95 ± 1.01 N and stainless steel 51.49 ± 5.22 N. In this fracture model, there were no statistically significant differences in the structural characteristics of PLA 3.5-mm. screws and stainless steel screws in oblique closing base wedge osteotomies of the first metatarsal.

Original languageEnglish (US)
Pages (from-to)249-254
Number of pages6
JournalJournal of Foot and Ankle Surgery
Volume33
Issue number3
StatePublished - 1994

Fingerprint

Metatarsal Bones
Stainless Steel
Osteotomy
Materials Testing
poly(lactic acid)
Confidence Intervals
Students

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Surgery

Cite this

Mechanical characteristics of poly-L-lactic acid absorbable screws and stainless steel screws in basilar osteotomies of the first metatarsal. / Lavery, L. A.; Higgins, K. R.; Ashry, H. R.; Athanasiou, K. A.

In: Journal of Foot and Ankle Surgery, Vol. 33, No. 3, 1994, p. 249-254.

Research output: Contribution to journalArticle

@article{1c5ba279510042ee8cac22adbf11cb9a,
title = "Mechanical characteristics of poly-L-lactic acid absorbable screws and stainless steel screws in basilar osteotomies of the first metatarsal",
abstract = "The purpose of this study is to evaluate the structural characteristics of 3.5-mm, stainless steel cortical screws and poly-L-lactic acid (PLA) absorbable screws in oblique closing base wedge osteotomies of the first metatarsal. Six pairs of frozen first metatarsal bones were excised from the specimen group. An oblique base wedge osteotomy was performed and fixated with either a 3.5-mm. stainless steel or PLA screw. Specimens were loaded to failure with the Bionix Material Testing System at a constant rate of 0.166 mm./sec. A Student's t test for paired samples with a 95{\%} confidence interval was used to measure differences in ultimate load, ultimate displacement, and structural stiffness. The following results (mean ± standard deviation) were obtained. Structural stiffness, PLA 12.35 ± 3.82 N/mm, and stainless steel 10.13 ± 5.74 N/mm.: ultimate displacement, PLA 7.39 ± 3.23 mm. and stainless steel 10.89 ± 7.91 mm., ultimate load, PLA 57.95 ± 1.01 N and stainless steel 51.49 ± 5.22 N. In this fracture model, there were no statistically significant differences in the structural characteristics of PLA 3.5-mm. screws and stainless steel screws in oblique closing base wedge osteotomies of the first metatarsal.",
author = "Lavery, {L. A.} and Higgins, {K. R.} and Ashry, {H. R.} and Athanasiou, {K. A.}",
year = "1994",
language = "English (US)",
volume = "33",
pages = "249--254",
journal = "Journal of Foot and Ankle Surgery",
issn = "1067-2516",
publisher = "Academic Press Inc.",
number = "3",

}

TY - JOUR

T1 - Mechanical characteristics of poly-L-lactic acid absorbable screws and stainless steel screws in basilar osteotomies of the first metatarsal

AU - Lavery, L. A.

AU - Higgins, K. R.

AU - Ashry, H. R.

AU - Athanasiou, K. A.

PY - 1994

Y1 - 1994

N2 - The purpose of this study is to evaluate the structural characteristics of 3.5-mm, stainless steel cortical screws and poly-L-lactic acid (PLA) absorbable screws in oblique closing base wedge osteotomies of the first metatarsal. Six pairs of frozen first metatarsal bones were excised from the specimen group. An oblique base wedge osteotomy was performed and fixated with either a 3.5-mm. stainless steel or PLA screw. Specimens were loaded to failure with the Bionix Material Testing System at a constant rate of 0.166 mm./sec. A Student's t test for paired samples with a 95% confidence interval was used to measure differences in ultimate load, ultimate displacement, and structural stiffness. The following results (mean ± standard deviation) were obtained. Structural stiffness, PLA 12.35 ± 3.82 N/mm, and stainless steel 10.13 ± 5.74 N/mm.: ultimate displacement, PLA 7.39 ± 3.23 mm. and stainless steel 10.89 ± 7.91 mm., ultimate load, PLA 57.95 ± 1.01 N and stainless steel 51.49 ± 5.22 N. In this fracture model, there were no statistically significant differences in the structural characteristics of PLA 3.5-mm. screws and stainless steel screws in oblique closing base wedge osteotomies of the first metatarsal.

AB - The purpose of this study is to evaluate the structural characteristics of 3.5-mm, stainless steel cortical screws and poly-L-lactic acid (PLA) absorbable screws in oblique closing base wedge osteotomies of the first metatarsal. Six pairs of frozen first metatarsal bones were excised from the specimen group. An oblique base wedge osteotomy was performed and fixated with either a 3.5-mm. stainless steel or PLA screw. Specimens were loaded to failure with the Bionix Material Testing System at a constant rate of 0.166 mm./sec. A Student's t test for paired samples with a 95% confidence interval was used to measure differences in ultimate load, ultimate displacement, and structural stiffness. The following results (mean ± standard deviation) were obtained. Structural stiffness, PLA 12.35 ± 3.82 N/mm, and stainless steel 10.13 ± 5.74 N/mm.: ultimate displacement, PLA 7.39 ± 3.23 mm. and stainless steel 10.89 ± 7.91 mm., ultimate load, PLA 57.95 ± 1.01 N and stainless steel 51.49 ± 5.22 N. In this fracture model, there were no statistically significant differences in the structural characteristics of PLA 3.5-mm. screws and stainless steel screws in oblique closing base wedge osteotomies of the first metatarsal.

UR - http://www.scopus.com/inward/record.url?scp=0028352064&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028352064&partnerID=8YFLogxK

M3 - Article

VL - 33

SP - 249

EP - 254

JO - Journal of Foot and Ankle Surgery

JF - Journal of Foot and Ankle Surgery

SN - 1067-2516

IS - 3

ER -