Mechanism of parenchymal enhancement of the liver with a microbubble-based US contrast medium: An intravital microscopy study in rats

Yuko Kono, Gregory C. Steinbach, Thomas Peterson, Geert W. Schmid-Schönbein, Robert F. Mattrey

Research output: Contribution to journalArticle

55 Citations (Scopus)

Abstract

PURPOSE: To investigate the mechanism of prolonged contrast material enhancement of the liver observed with the lipid-shell ultrasonographic (US) contrast agent AF0150, with use of intravital microscopy. MATERIALS AND METHODS: Eight Sprague-Dawley rats were used. Six received fluoroscent microspheres to label the Kupffer cells; two were used as controls. The edge of the middle lobe of the liver was transilluminated with white light. Fluorescent microspheres were observed under fluorescence light. After injection of AF0150, behavior of microbubbles was observed for 6 minutes while viewing a single high-power field. Multiple other fields were then assessed for stationary bubbles and their relation to Kupffer cells. The number of bubbles in motion, aggregated, stationary, and associated with labeled cells were counted. RESULTS: Of 590 bubbles, 34 (5.8%) became stationary and 556 (94.2%) kept moving. Of the 34 stationary microbubbles, 21 dislodged within 30 seconds. Microbubbles were homogeneously distributed throughout the lobule, in contrast to the dominant periportal distribution of the labeled Kupffer cells. Among 83 stationary bubbles observed from all fields of view, only 14 (17%) were associated with fluorescent-labeled cells. CONCLUSION: The late parenchymal liver enhancement effect of AF0150 is likely not related to Kupffer-cell uptake, but rather to a mechanical slowdown within the sinusoids.

Original languageEnglish (US)
Pages (from-to)253-257
Number of pages5
JournalRadiology
Volume224
Issue number1
DOIs
StatePublished - Jan 1 2002

Fingerprint

Microbubbles
Kupffer Cells
Contrast Media
Liver
Microspheres
Light
Sprague Dawley Rats
Fluorescence
Lipids
Injections
Intravital Microscopy

Keywords

  • Experimental study
  • Liver, US
  • Microbubbles
  • Ultrasound (US), contrast media

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Mechanism of parenchymal enhancement of the liver with a microbubble-based US contrast medium : An intravital microscopy study in rats. / Kono, Yuko; Steinbach, Gregory C.; Peterson, Thomas; Schmid-Schönbein, Geert W.; Mattrey, Robert F.

In: Radiology, Vol. 224, No. 1, 01.01.2002, p. 253-257.

Research output: Contribution to journalArticle

Kono, Yuko ; Steinbach, Gregory C. ; Peterson, Thomas ; Schmid-Schönbein, Geert W. ; Mattrey, Robert F. / Mechanism of parenchymal enhancement of the liver with a microbubble-based US contrast medium : An intravital microscopy study in rats. In: Radiology. 2002 ; Vol. 224, No. 1. pp. 253-257.
@article{9b1c78ab02a74a9fbdb2fb10a8c53ba3,
title = "Mechanism of parenchymal enhancement of the liver with a microbubble-based US contrast medium: An intravital microscopy study in rats",
abstract = "PURPOSE: To investigate the mechanism of prolonged contrast material enhancement of the liver observed with the lipid-shell ultrasonographic (US) contrast agent AF0150, with use of intravital microscopy. MATERIALS AND METHODS: Eight Sprague-Dawley rats were used. Six received fluoroscent microspheres to label the Kupffer cells; two were used as controls. The edge of the middle lobe of the liver was transilluminated with white light. Fluorescent microspheres were observed under fluorescence light. After injection of AF0150, behavior of microbubbles was observed for 6 minutes while viewing a single high-power field. Multiple other fields were then assessed for stationary bubbles and their relation to Kupffer cells. The number of bubbles in motion, aggregated, stationary, and associated with labeled cells were counted. RESULTS: Of 590 bubbles, 34 (5.8{\%}) became stationary and 556 (94.2{\%}) kept moving. Of the 34 stationary microbubbles, 21 dislodged within 30 seconds. Microbubbles were homogeneously distributed throughout the lobule, in contrast to the dominant periportal distribution of the labeled Kupffer cells. Among 83 stationary bubbles observed from all fields of view, only 14 (17{\%}) were associated with fluorescent-labeled cells. CONCLUSION: The late parenchymal liver enhancement effect of AF0150 is likely not related to Kupffer-cell uptake, but rather to a mechanical slowdown within the sinusoids.",
keywords = "Experimental study, Liver, US, Microbubbles, Ultrasound (US), contrast media",
author = "Yuko Kono and Steinbach, {Gregory C.} and Thomas Peterson and Schmid-Sch{\"o}nbein, {Geert W.} and Mattrey, {Robert F.}",
year = "2002",
month = "1",
day = "1",
doi = "10.1148/radiol.2241011352",
language = "English (US)",
volume = "224",
pages = "253--257",
journal = "Radiology",
issn = "0033-8419",
publisher = "Radiological Society of North America Inc.",
number = "1",

}

TY - JOUR

T1 - Mechanism of parenchymal enhancement of the liver with a microbubble-based US contrast medium

T2 - An intravital microscopy study in rats

AU - Kono, Yuko

AU - Steinbach, Gregory C.

AU - Peterson, Thomas

AU - Schmid-Schönbein, Geert W.

AU - Mattrey, Robert F.

PY - 2002/1/1

Y1 - 2002/1/1

N2 - PURPOSE: To investigate the mechanism of prolonged contrast material enhancement of the liver observed with the lipid-shell ultrasonographic (US) contrast agent AF0150, with use of intravital microscopy. MATERIALS AND METHODS: Eight Sprague-Dawley rats were used. Six received fluoroscent microspheres to label the Kupffer cells; two were used as controls. The edge of the middle lobe of the liver was transilluminated with white light. Fluorescent microspheres were observed under fluorescence light. After injection of AF0150, behavior of microbubbles was observed for 6 minutes while viewing a single high-power field. Multiple other fields were then assessed for stationary bubbles and their relation to Kupffer cells. The number of bubbles in motion, aggregated, stationary, and associated with labeled cells were counted. RESULTS: Of 590 bubbles, 34 (5.8%) became stationary and 556 (94.2%) kept moving. Of the 34 stationary microbubbles, 21 dislodged within 30 seconds. Microbubbles were homogeneously distributed throughout the lobule, in contrast to the dominant periportal distribution of the labeled Kupffer cells. Among 83 stationary bubbles observed from all fields of view, only 14 (17%) were associated with fluorescent-labeled cells. CONCLUSION: The late parenchymal liver enhancement effect of AF0150 is likely not related to Kupffer-cell uptake, but rather to a mechanical slowdown within the sinusoids.

AB - PURPOSE: To investigate the mechanism of prolonged contrast material enhancement of the liver observed with the lipid-shell ultrasonographic (US) contrast agent AF0150, with use of intravital microscopy. MATERIALS AND METHODS: Eight Sprague-Dawley rats were used. Six received fluoroscent microspheres to label the Kupffer cells; two were used as controls. The edge of the middle lobe of the liver was transilluminated with white light. Fluorescent microspheres were observed under fluorescence light. After injection of AF0150, behavior of microbubbles was observed for 6 minutes while viewing a single high-power field. Multiple other fields were then assessed for stationary bubbles and their relation to Kupffer cells. The number of bubbles in motion, aggregated, stationary, and associated with labeled cells were counted. RESULTS: Of 590 bubbles, 34 (5.8%) became stationary and 556 (94.2%) kept moving. Of the 34 stationary microbubbles, 21 dislodged within 30 seconds. Microbubbles were homogeneously distributed throughout the lobule, in contrast to the dominant periportal distribution of the labeled Kupffer cells. Among 83 stationary bubbles observed from all fields of view, only 14 (17%) were associated with fluorescent-labeled cells. CONCLUSION: The late parenchymal liver enhancement effect of AF0150 is likely not related to Kupffer-cell uptake, but rather to a mechanical slowdown within the sinusoids.

KW - Experimental study

KW - Liver, US

KW - Microbubbles

KW - Ultrasound (US), contrast media

UR - http://www.scopus.com/inward/record.url?scp=0036082378&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036082378&partnerID=8YFLogxK

U2 - 10.1148/radiol.2241011352

DO - 10.1148/radiol.2241011352

M3 - Article

C2 - 12091692

AN - SCOPUS:0036082378

VL - 224

SP - 253

EP - 257

JO - Radiology

JF - Radiology

SN - 0033-8419

IS - 1

ER -