Micro-SPECT using NaI(Tl) crystals

E. Tsyganov, P. Antich, R. Parkey, S. Selunin, N. Slavine, T. Soesbe

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

A NaI(Tl) based micro-SPECT device that uses pinhole collimator geometiy to achieve spatial resolution demagnication is proposed. This detector is based on our previous work in which a novel technique for 3-D position measurement within thick scintillators was developed. Properties of the new detector were studied using a collimated 57Co source and a 6 mm thick NaI(Tl) crystal that was coupled to a Hamamatsu R2486 position-sensitive photo-multiplier tube (PSPMT). All of the crystal surfaces (except the surface in contact with the PSPMT) were blackened so that an undistorted scintillation light cone resulting from total internal reflection would impinge on the photocathode, which is needed for an accurate Depth Of Interaction (DOI) measurement within the crystal. The spatial resolution in the plane of detector was shown to be better than 1 mm FWHM. The DOI could be measured with an error of about 1 mm FWHM using the light cone parameters. 3-D image reconstruction software based on the MLEM algorithm was developed using Monte Carlo events. Applied to the real data obtained in a realistic geometry of the device, MLEM gives a better than 0.8 mm FWHM resolution in the plane of the 57Co source. In Monte Carlo calculations, for a detector resolution of 1 mm with a 0.5 mm pinhole collimator, the spatial resolution was demonstrated to be about 0.4 mm FWHM for a point-like source.

Original languageEnglish (US)
Title of host publicationIEEE Nuclear Science Symposium Conference Record
EditorsS.D. Metzler
Pages1805-1809
Number of pages5
Volume3
StatePublished - 2003
Event2003 IEEE Nuclear Science Symposium Conference Record - Nuclear Science Symposium, Medical Imaging Conference - Portland, OR, United States
Duration: Oct 19 2003Oct 25 2003

Other

Other2003 IEEE Nuclear Science Symposium Conference Record - Nuclear Science Symposium, Medical Imaging Conference
CountryUnited States
CityPortland, OR
Period10/19/0310/25/03

Fingerprint

Full width at half maximum
Detectors
Crystals
Cones
Position measurement
Photocathodes
Scintillation
Image reconstruction
Phosphors
Geometry

ASJC Scopus subject areas

  • Computer Vision and Pattern Recognition
  • Industrial and Manufacturing Engineering

Cite this

Tsyganov, E., Antich, P., Parkey, R., Selunin, S., Slavine, N., & Soesbe, T. (2003). Micro-SPECT using NaI(Tl) crystals. In S. D. Metzler (Ed.), IEEE Nuclear Science Symposium Conference Record (Vol. 3, pp. 1805-1809). [M3-31]

Micro-SPECT using NaI(Tl) crystals. / Tsyganov, E.; Antich, P.; Parkey, R.; Selunin, S.; Slavine, N.; Soesbe, T.

IEEE Nuclear Science Symposium Conference Record. ed. / S.D. Metzler. Vol. 3 2003. p. 1805-1809 M3-31.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Tsyganov, E, Antich, P, Parkey, R, Selunin, S, Slavine, N & Soesbe, T 2003, Micro-SPECT using NaI(Tl) crystals. in SD Metzler (ed.), IEEE Nuclear Science Symposium Conference Record. vol. 3, M3-31, pp. 1805-1809, 2003 IEEE Nuclear Science Symposium Conference Record - Nuclear Science Symposium, Medical Imaging Conference, Portland, OR, United States, 10/19/03.
Tsyganov E, Antich P, Parkey R, Selunin S, Slavine N, Soesbe T. Micro-SPECT using NaI(Tl) crystals. In Metzler SD, editor, IEEE Nuclear Science Symposium Conference Record. Vol. 3. 2003. p. 1805-1809. M3-31
Tsyganov, E. ; Antich, P. ; Parkey, R. ; Selunin, S. ; Slavine, N. ; Soesbe, T. / Micro-SPECT using NaI(Tl) crystals. IEEE Nuclear Science Symposium Conference Record. editor / S.D. Metzler. Vol. 3 2003. pp. 1805-1809
@inproceedings{12acde7139454c6eb931b6510f0749c6,
title = "Micro-SPECT using NaI(Tl) crystals",
abstract = "A NaI(Tl) based micro-SPECT device that uses pinhole collimator geometiy to achieve spatial resolution demagnication is proposed. This detector is based on our previous work in which a novel technique for 3-D position measurement within thick scintillators was developed. Properties of the new detector were studied using a collimated 57Co source and a 6 mm thick NaI(Tl) crystal that was coupled to a Hamamatsu R2486 position-sensitive photo-multiplier tube (PSPMT). All of the crystal surfaces (except the surface in contact with the PSPMT) were blackened so that an undistorted scintillation light cone resulting from total internal reflection would impinge on the photocathode, which is needed for an accurate Depth Of Interaction (DOI) measurement within the crystal. The spatial resolution in the plane of detector was shown to be better than 1 mm FWHM. The DOI could be measured with an error of about 1 mm FWHM using the light cone parameters. 3-D image reconstruction software based on the MLEM algorithm was developed using Monte Carlo events. Applied to the real data obtained in a realistic geometry of the device, MLEM gives a better than 0.8 mm FWHM resolution in the plane of the 57Co source. In Monte Carlo calculations, for a detector resolution of 1 mm with a 0.5 mm pinhole collimator, the spatial resolution was demonstrated to be about 0.4 mm FWHM for a point-like source.",
author = "E. Tsyganov and P. Antich and R. Parkey and S. Selunin and N. Slavine and T. Soesbe",
year = "2003",
language = "English (US)",
volume = "3",
pages = "1805--1809",
editor = "S.D. Metzler",
booktitle = "IEEE Nuclear Science Symposium Conference Record",

}

TY - GEN

T1 - Micro-SPECT using NaI(Tl) crystals

AU - Tsyganov, E.

AU - Antich, P.

AU - Parkey, R.

AU - Selunin, S.

AU - Slavine, N.

AU - Soesbe, T.

PY - 2003

Y1 - 2003

N2 - A NaI(Tl) based micro-SPECT device that uses pinhole collimator geometiy to achieve spatial resolution demagnication is proposed. This detector is based on our previous work in which a novel technique for 3-D position measurement within thick scintillators was developed. Properties of the new detector were studied using a collimated 57Co source and a 6 mm thick NaI(Tl) crystal that was coupled to a Hamamatsu R2486 position-sensitive photo-multiplier tube (PSPMT). All of the crystal surfaces (except the surface in contact with the PSPMT) were blackened so that an undistorted scintillation light cone resulting from total internal reflection would impinge on the photocathode, which is needed for an accurate Depth Of Interaction (DOI) measurement within the crystal. The spatial resolution in the plane of detector was shown to be better than 1 mm FWHM. The DOI could be measured with an error of about 1 mm FWHM using the light cone parameters. 3-D image reconstruction software based on the MLEM algorithm was developed using Monte Carlo events. Applied to the real data obtained in a realistic geometry of the device, MLEM gives a better than 0.8 mm FWHM resolution in the plane of the 57Co source. In Monte Carlo calculations, for a detector resolution of 1 mm with a 0.5 mm pinhole collimator, the spatial resolution was demonstrated to be about 0.4 mm FWHM for a point-like source.

AB - A NaI(Tl) based micro-SPECT device that uses pinhole collimator geometiy to achieve spatial resolution demagnication is proposed. This detector is based on our previous work in which a novel technique for 3-D position measurement within thick scintillators was developed. Properties of the new detector were studied using a collimated 57Co source and a 6 mm thick NaI(Tl) crystal that was coupled to a Hamamatsu R2486 position-sensitive photo-multiplier tube (PSPMT). All of the crystal surfaces (except the surface in contact with the PSPMT) were blackened so that an undistorted scintillation light cone resulting from total internal reflection would impinge on the photocathode, which is needed for an accurate Depth Of Interaction (DOI) measurement within the crystal. The spatial resolution in the plane of detector was shown to be better than 1 mm FWHM. The DOI could be measured with an error of about 1 mm FWHM using the light cone parameters. 3-D image reconstruction software based on the MLEM algorithm was developed using Monte Carlo events. Applied to the real data obtained in a realistic geometry of the device, MLEM gives a better than 0.8 mm FWHM resolution in the plane of the 57Co source. In Monte Carlo calculations, for a detector resolution of 1 mm with a 0.5 mm pinhole collimator, the spatial resolution was demonstrated to be about 0.4 mm FWHM for a point-like source.

UR - http://www.scopus.com/inward/record.url?scp=11844282752&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=11844282752&partnerID=8YFLogxK

M3 - Conference contribution

VL - 3

SP - 1805

EP - 1809

BT - IEEE Nuclear Science Symposium Conference Record

A2 - Metzler, S.D.

ER -