Model of magnetically guided fetal cardiac intervention: Potential to avoid direct cardiac puncture

Alan W. Nugent, Robert C. Kowal, Amy L. Juraszek, Catherine Ikemba, Kevin Magee

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Objective: Fetal cardiac interventions are performed via direct cardiac puncture and are associated with significant fetal morbidity. The feasibility of utilizing magnetic navigation to maneuver a guide wire and balloon across a fetal aortic valve without direct cardiac puncture is tested. Methods: A fetal heart model was manufactured and placed in a catheterization laboratory equipped with magnetic navigation. Magnetically steerable guide wires along with commercially available coronary balloons were inserted into the model at a site mimicking a hepatic vein. Results: Passage of the wire and balloon was achieved on every attempt. The model was suitable for testing although the structural characteristics of the model made wire passage from the right to the left atrium the most challenging aspect. Once the wire was positioned in the left ventricle, it was easily maneuvered 180 degrees towards the left ventricular outflow tract and then the descending aorta. Advancement of a coronary balloon over this wire was uncomplicated. Conclusion: In a fetal heart model, it is feasible to deliver a wire and balloon from abdominal venous access antegrade across the aortic valve. Progression to fetal lamb models is planned and may advance fetal cardiac interventions by reduction of fetal morbidity.

Original languageEnglish (US)
Pages (from-to)1778-1781
Number of pages4
JournalJournal of Maternal-Fetal and Neonatal Medicine
Volume26
Issue number18
DOIs
StatePublished - Dec 2013

Fingerprint

Fetal Heart
Aortic Valve
Punctures
Multifetal Pregnancy Reduction
Morbidity
Hepatic Veins
Structural Models
Heart Atria
Thoracic Aorta
Catheterization
Heart Ventricles

Keywords

  • Anatomic models
  • Balloon valvuloplasty
  • Fetal heart
  • Fetal therapy

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Obstetrics and Gynecology

Cite this

Model of magnetically guided fetal cardiac intervention : Potential to avoid direct cardiac puncture. / Nugent, Alan W.; Kowal, Robert C.; Juraszek, Amy L.; Ikemba, Catherine; Magee, Kevin.

In: Journal of Maternal-Fetal and Neonatal Medicine, Vol. 26, No. 18, 12.2013, p. 1778-1781.

Research output: Contribution to journalArticle

@article{5a4056d0d09841af81b86520e481eb23,
title = "Model of magnetically guided fetal cardiac intervention: Potential to avoid direct cardiac puncture",
abstract = "Objective: Fetal cardiac interventions are performed via direct cardiac puncture and are associated with significant fetal morbidity. The feasibility of utilizing magnetic navigation to maneuver a guide wire and balloon across a fetal aortic valve without direct cardiac puncture is tested. Methods: A fetal heart model was manufactured and placed in a catheterization laboratory equipped with magnetic navigation. Magnetically steerable guide wires along with commercially available coronary balloons were inserted into the model at a site mimicking a hepatic vein. Results: Passage of the wire and balloon was achieved on every attempt. The model was suitable for testing although the structural characteristics of the model made wire passage from the right to the left atrium the most challenging aspect. Once the wire was positioned in the left ventricle, it was easily maneuvered 180 degrees towards the left ventricular outflow tract and then the descending aorta. Advancement of a coronary balloon over this wire was uncomplicated. Conclusion: In a fetal heart model, it is feasible to deliver a wire and balloon from abdominal venous access antegrade across the aortic valve. Progression to fetal lamb models is planned and may advance fetal cardiac interventions by reduction of fetal morbidity.",
keywords = "Anatomic models, Balloon valvuloplasty, Fetal heart, Fetal therapy",
author = "Nugent, {Alan W.} and Kowal, {Robert C.} and Juraszek, {Amy L.} and Catherine Ikemba and Kevin Magee",
year = "2013",
month = "12",
doi = "10.3109/14767058.2013.818116",
language = "English (US)",
volume = "26",
pages = "1778--1781",
journal = "Journal of Maternal-Fetal and Neonatal Medicine",
issn = "1476-7058",
publisher = "Informa Healthcare",
number = "18",

}

TY - JOUR

T1 - Model of magnetically guided fetal cardiac intervention

T2 - Potential to avoid direct cardiac puncture

AU - Nugent, Alan W.

AU - Kowal, Robert C.

AU - Juraszek, Amy L.

AU - Ikemba, Catherine

AU - Magee, Kevin

PY - 2013/12

Y1 - 2013/12

N2 - Objective: Fetal cardiac interventions are performed via direct cardiac puncture and are associated with significant fetal morbidity. The feasibility of utilizing magnetic navigation to maneuver a guide wire and balloon across a fetal aortic valve without direct cardiac puncture is tested. Methods: A fetal heart model was manufactured and placed in a catheterization laboratory equipped with magnetic navigation. Magnetically steerable guide wires along with commercially available coronary balloons were inserted into the model at a site mimicking a hepatic vein. Results: Passage of the wire and balloon was achieved on every attempt. The model was suitable for testing although the structural characteristics of the model made wire passage from the right to the left atrium the most challenging aspect. Once the wire was positioned in the left ventricle, it was easily maneuvered 180 degrees towards the left ventricular outflow tract and then the descending aorta. Advancement of a coronary balloon over this wire was uncomplicated. Conclusion: In a fetal heart model, it is feasible to deliver a wire and balloon from abdominal venous access antegrade across the aortic valve. Progression to fetal lamb models is planned and may advance fetal cardiac interventions by reduction of fetal morbidity.

AB - Objective: Fetal cardiac interventions are performed via direct cardiac puncture and are associated with significant fetal morbidity. The feasibility of utilizing magnetic navigation to maneuver a guide wire and balloon across a fetal aortic valve without direct cardiac puncture is tested. Methods: A fetal heart model was manufactured and placed in a catheterization laboratory equipped with magnetic navigation. Magnetically steerable guide wires along with commercially available coronary balloons were inserted into the model at a site mimicking a hepatic vein. Results: Passage of the wire and balloon was achieved on every attempt. The model was suitable for testing although the structural characteristics of the model made wire passage from the right to the left atrium the most challenging aspect. Once the wire was positioned in the left ventricle, it was easily maneuvered 180 degrees towards the left ventricular outflow tract and then the descending aorta. Advancement of a coronary balloon over this wire was uncomplicated. Conclusion: In a fetal heart model, it is feasible to deliver a wire and balloon from abdominal venous access antegrade across the aortic valve. Progression to fetal lamb models is planned and may advance fetal cardiac interventions by reduction of fetal morbidity.

KW - Anatomic models

KW - Balloon valvuloplasty

KW - Fetal heart

KW - Fetal therapy

UR - http://www.scopus.com/inward/record.url?scp=84887977116&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84887977116&partnerID=8YFLogxK

U2 - 10.3109/14767058.2013.818116

DO - 10.3109/14767058.2013.818116

M3 - Article

C2 - 23795581

AN - SCOPUS:84887977116

VL - 26

SP - 1778

EP - 1781

JO - Journal of Maternal-Fetal and Neonatal Medicine

JF - Journal of Maternal-Fetal and Neonatal Medicine

SN - 1476-7058

IS - 18

ER -