Modified Friedman technique: a new proposed method of measuring glenoid version in the setting of glenohumeral dysplasia

Matthew G. Ditzler, J. Herman Kan, Maddy Artunduaga, Siddharth P. Jadhav, Bryce R. Bell, Wei Zhang, Robert C. Orth

Research output: Contribution to journalArticle

Abstract

Background: Glenoid version angles are measured to objectively follow changes related to glenohumeral dysplasia in the setting of brachial plexus birth palsy. Measuring glenoid version on cross-sectional imaging was initially described by Friedman et al. in 1992. Recent literature for non-dysplastic shoulders advocates time-consuming reconstructions and reformations for an accurate assessment of glenoid version. Objective: To compare Friedman’s original method for measuring glenoid version to a novel technique we developed (“modified Friedman”) with the reference standard of true axial reformations. Materials and methods: With institutional review board approval, we retrospectively examined 30 normal and dysplastic shoulders obtained from magnetic resonance imaging examinations of 30 patients with an established diagnosis of brachial plexus birth palsy between January 2012 and September 2017. Four pediatric radiologists performed glenoid version measurements using Friedman’s method, the modified Friedman method and a previously described true axial reformation method. The modified Friedman technique better accounts for scapular positioning by selecting a reference point related to the acromion-scapular body interface. Inter-rater reliability and inter-method agreement were assessed using intraclass correlation, paired t-tests and mixed linear model analysis. Equivalence tests between methods were performed per reader. Results: Glenoid version measurements were significantly different when comparing Friedman’s method to true axial reformations in normal (-10.8±5.7° [mean±standard deviation] vs. -8.8±5.3°; P≤0.001) and dysplastic shoulders (-34.6±17.7° vs. -28.1±17.5°; P≤0.001). Glenoid version measurements were not significantly different when comparing the modified Friedman’s method to true axial reformations in normal (-6.3±5.8° vs. -8.8±5.3°; P=0.06) and dysplastic shoulders (-29.0±18.3° vs. -28.1±17.5°; P=0.06). Friedman’s method was not equivalent to true axial reformations for measurements in dysplastic shoulders for all readers (P=0.68, 0.81, 0.86, 0.99); the modified Friedman method was equivalent to of true axial reformations for measurements in dysplastic shoulders for 3 of 4 readers (P≤0.001, P≤0.001, P≤0.001, P=0.10). Conclusion: In glenohumeral dysplasia, the modified Friedman method and post-processed true axial reformations provide statistically similar and reproducible values. We propose that our modified Friedman technique can be performed in lieu of post-processed true axial reformations to generate glenoid version measurements.

Original languageEnglish (US)
Pages (from-to)1779-1785
Number of pages7
JournalPediatric Radiology
Volume48
Issue number12
DOIs
StatePublished - Nov 1 2018
Externally publishedYes

Fingerprint

Brachial Plexus
Paralysis
Acromion
Parturition
Research Ethics Committees
Linear Models
Magnetic Resonance Imaging
Pediatrics
Radiologists

Keywords

  • Brachial plexus birth palsy
  • Children
  • Glenohumeral dysplasia
  • Glenoid version
  • Magnetic resonance imaging
  • Shoulder

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Radiology Nuclear Medicine and imaging

Cite this

Modified Friedman technique : a new proposed method of measuring glenoid version in the setting of glenohumeral dysplasia. / Ditzler, Matthew G.; Kan, J. Herman; Artunduaga, Maddy; Jadhav, Siddharth P.; Bell, Bryce R.; Zhang, Wei; Orth, Robert C.

In: Pediatric Radiology, Vol. 48, No. 12, 01.11.2018, p. 1779-1785.

Research output: Contribution to journalArticle

Ditzler, Matthew G. ; Kan, J. Herman ; Artunduaga, Maddy ; Jadhav, Siddharth P. ; Bell, Bryce R. ; Zhang, Wei ; Orth, Robert C. / Modified Friedman technique : a new proposed method of measuring glenoid version in the setting of glenohumeral dysplasia. In: Pediatric Radiology. 2018 ; Vol. 48, No. 12. pp. 1779-1785.
@article{f042cd94cc3a4018a7782b1d7a206d79,
title = "Modified Friedman technique: a new proposed method of measuring glenoid version in the setting of glenohumeral dysplasia",
abstract = "Background: Glenoid version angles are measured to objectively follow changes related to glenohumeral dysplasia in the setting of brachial plexus birth palsy. Measuring glenoid version on cross-sectional imaging was initially described by Friedman et al. in 1992. Recent literature for non-dysplastic shoulders advocates time-consuming reconstructions and reformations for an accurate assessment of glenoid version. Objective: To compare Friedman’s original method for measuring glenoid version to a novel technique we developed (“modified Friedman”) with the reference standard of true axial reformations. Materials and methods: With institutional review board approval, we retrospectively examined 30 normal and dysplastic shoulders obtained from magnetic resonance imaging examinations of 30 patients with an established diagnosis of brachial plexus birth palsy between January 2012 and September 2017. Four pediatric radiologists performed glenoid version measurements using Friedman’s method, the modified Friedman method and a previously described true axial reformation method. The modified Friedman technique better accounts for scapular positioning by selecting a reference point related to the acromion-scapular body interface. Inter-rater reliability and inter-method agreement were assessed using intraclass correlation, paired t-tests and mixed linear model analysis. Equivalence tests between methods were performed per reader. Results: Glenoid version measurements were significantly different when comparing Friedman’s method to true axial reformations in normal (-10.8±5.7° [mean±standard deviation] vs. -8.8±5.3°; P≤0.001) and dysplastic shoulders (-34.6±17.7° vs. -28.1±17.5°; P≤0.001). Glenoid version measurements were not significantly different when comparing the modified Friedman’s method to true axial reformations in normal (-6.3±5.8° vs. -8.8±5.3°; P=0.06) and dysplastic shoulders (-29.0±18.3° vs. -28.1±17.5°; P=0.06). Friedman’s method was not equivalent to true axial reformations for measurements in dysplastic shoulders for all readers (P=0.68, 0.81, 0.86, 0.99); the modified Friedman method was equivalent to of true axial reformations for measurements in dysplastic shoulders for 3 of 4 readers (P≤0.001, P≤0.001, P≤0.001, P=0.10). Conclusion: In glenohumeral dysplasia, the modified Friedman method and post-processed true axial reformations provide statistically similar and reproducible values. We propose that our modified Friedman technique can be performed in lieu of post-processed true axial reformations to generate glenoid version measurements.",
keywords = "Brachial plexus birth palsy, Children, Glenohumeral dysplasia, Glenoid version, Magnetic resonance imaging, Shoulder",
author = "Ditzler, {Matthew G.} and Kan, {J. Herman} and Maddy Artunduaga and Jadhav, {Siddharth P.} and Bell, {Bryce R.} and Wei Zhang and Orth, {Robert C.}",
year = "2018",
month = "11",
day = "1",
doi = "10.1007/s00247-018-4196-7",
language = "English (US)",
volume = "48",
pages = "1779--1785",
journal = "Pediatric Radiology",
issn = "0301-0449",
publisher = "Springer Verlag",
number = "12",

}

TY - JOUR

T1 - Modified Friedman technique

T2 - a new proposed method of measuring glenoid version in the setting of glenohumeral dysplasia

AU - Ditzler, Matthew G.

AU - Kan, J. Herman

AU - Artunduaga, Maddy

AU - Jadhav, Siddharth P.

AU - Bell, Bryce R.

AU - Zhang, Wei

AU - Orth, Robert C.

PY - 2018/11/1

Y1 - 2018/11/1

N2 - Background: Glenoid version angles are measured to objectively follow changes related to glenohumeral dysplasia in the setting of brachial plexus birth palsy. Measuring glenoid version on cross-sectional imaging was initially described by Friedman et al. in 1992. Recent literature for non-dysplastic shoulders advocates time-consuming reconstructions and reformations for an accurate assessment of glenoid version. Objective: To compare Friedman’s original method for measuring glenoid version to a novel technique we developed (“modified Friedman”) with the reference standard of true axial reformations. Materials and methods: With institutional review board approval, we retrospectively examined 30 normal and dysplastic shoulders obtained from magnetic resonance imaging examinations of 30 patients with an established diagnosis of brachial plexus birth palsy between January 2012 and September 2017. Four pediatric radiologists performed glenoid version measurements using Friedman’s method, the modified Friedman method and a previously described true axial reformation method. The modified Friedman technique better accounts for scapular positioning by selecting a reference point related to the acromion-scapular body interface. Inter-rater reliability and inter-method agreement were assessed using intraclass correlation, paired t-tests and mixed linear model analysis. Equivalence tests between methods were performed per reader. Results: Glenoid version measurements were significantly different when comparing Friedman’s method to true axial reformations in normal (-10.8±5.7° [mean±standard deviation] vs. -8.8±5.3°; P≤0.001) and dysplastic shoulders (-34.6±17.7° vs. -28.1±17.5°; P≤0.001). Glenoid version measurements were not significantly different when comparing the modified Friedman’s method to true axial reformations in normal (-6.3±5.8° vs. -8.8±5.3°; P=0.06) and dysplastic shoulders (-29.0±18.3° vs. -28.1±17.5°; P=0.06). Friedman’s method was not equivalent to true axial reformations for measurements in dysplastic shoulders for all readers (P=0.68, 0.81, 0.86, 0.99); the modified Friedman method was equivalent to of true axial reformations for measurements in dysplastic shoulders for 3 of 4 readers (P≤0.001, P≤0.001, P≤0.001, P=0.10). Conclusion: In glenohumeral dysplasia, the modified Friedman method and post-processed true axial reformations provide statistically similar and reproducible values. We propose that our modified Friedman technique can be performed in lieu of post-processed true axial reformations to generate glenoid version measurements.

AB - Background: Glenoid version angles are measured to objectively follow changes related to glenohumeral dysplasia in the setting of brachial plexus birth palsy. Measuring glenoid version on cross-sectional imaging was initially described by Friedman et al. in 1992. Recent literature for non-dysplastic shoulders advocates time-consuming reconstructions and reformations for an accurate assessment of glenoid version. Objective: To compare Friedman’s original method for measuring glenoid version to a novel technique we developed (“modified Friedman”) with the reference standard of true axial reformations. Materials and methods: With institutional review board approval, we retrospectively examined 30 normal and dysplastic shoulders obtained from magnetic resonance imaging examinations of 30 patients with an established diagnosis of brachial plexus birth palsy between January 2012 and September 2017. Four pediatric radiologists performed glenoid version measurements using Friedman’s method, the modified Friedman method and a previously described true axial reformation method. The modified Friedman technique better accounts for scapular positioning by selecting a reference point related to the acromion-scapular body interface. Inter-rater reliability and inter-method agreement were assessed using intraclass correlation, paired t-tests and mixed linear model analysis. Equivalence tests between methods were performed per reader. Results: Glenoid version measurements were significantly different when comparing Friedman’s method to true axial reformations in normal (-10.8±5.7° [mean±standard deviation] vs. -8.8±5.3°; P≤0.001) and dysplastic shoulders (-34.6±17.7° vs. -28.1±17.5°; P≤0.001). Glenoid version measurements were not significantly different when comparing the modified Friedman’s method to true axial reformations in normal (-6.3±5.8° vs. -8.8±5.3°; P=0.06) and dysplastic shoulders (-29.0±18.3° vs. -28.1±17.5°; P=0.06). Friedman’s method was not equivalent to true axial reformations for measurements in dysplastic shoulders for all readers (P=0.68, 0.81, 0.86, 0.99); the modified Friedman method was equivalent to of true axial reformations for measurements in dysplastic shoulders for 3 of 4 readers (P≤0.001, P≤0.001, P≤0.001, P=0.10). Conclusion: In glenohumeral dysplasia, the modified Friedman method and post-processed true axial reformations provide statistically similar and reproducible values. We propose that our modified Friedman technique can be performed in lieu of post-processed true axial reformations to generate glenoid version measurements.

KW - Brachial plexus birth palsy

KW - Children

KW - Glenohumeral dysplasia

KW - Glenoid version

KW - Magnetic resonance imaging

KW - Shoulder

UR - http://www.scopus.com/inward/record.url?scp=85049583558&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85049583558&partnerID=8YFLogxK

U2 - 10.1007/s00247-018-4196-7

DO - 10.1007/s00247-018-4196-7

M3 - Article

C2 - 29978295

AN - SCOPUS:85049583558

VL - 48

SP - 1779

EP - 1785

JO - Pediatric Radiology

JF - Pediatric Radiology

SN - 0301-0449

IS - 12

ER -