MR based PET attenuation correction (MRAC) and anatomical localization ofhuman brain using an optimized UTE-mDixon pulse sequence

Lingzhi Hu, Christian Stehning, Nghi Nguyen, Andrew Sher, Claudia Martinezrios, Zhiqiang Hu, Lingxiong Shao

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

MR based Attenuation Correction (MRAC) is essential for PET quantitation and image quality assurance in PET/MR. Ultra-short TE (UTE) sequence is promising in generating positive contrast for cortical bone but its further adoption is limited by prohibitively long scan time, lack of soft tissue contrast, and potential ambiguity in a tissue classification due to MR imaging artifacts. In this investigation, we aimed to develop a new MRAC method that consists an optimized under-sampled UTE-mDixon sequence and an iterative voxel-based tissue classification algorithm to generate 4-compartment μ-map, including water, fat, bone and air cavity. In vivo UTE-mDixon images were acquired on 12 human subjects and the developed segmentation method was employed for tissue classification. Diagnostic quality of MR images and the tissue classification accuracy for MRAC was evaluated by three radiologists independently. As a unique advantage over other MRAC sequences, the under-sampled UTE-mDixon of whole brain with retrospective trajectory delay calibration can be finished within less than 3 minutes providing both high quality water/fat separation images for anatomical localization and UTE images for bone segmentation. Robust tissue classification was achieved in all subjects as evaluated by radiologists. The developed MR scan methodology together with tissue classification algorithm may provide a one-scan solution for attenuation correction and anatomical localization in PET/MR.

Original languageEnglish (US)
Title of host publication2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Electronic)9781479960972
DOIs
StatePublished - Mar 10 2016
Externally publishedYes
EventIEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014 - Seattle, United States
Duration: Nov 8 2014Nov 15 2014

Publication series

Name2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014

Other

OtherIEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014
Country/TerritoryUnited States
CitySeattle
Period11/8/1411/15/14

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'MR based PET attenuation correction (MRAC) and anatomical localization ofhuman brain using an optimized UTE-mDixon pulse sequence'. Together they form a unique fingerprint.

Cite this