Novel rapid fat suppression strategy with spectrally selective pulses

Qi Peng, Roderick W. McColl, Jihong Wang, Paul T. Weatherall

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Short repetition time gradient echo sequences are gaining popularity in clinical applications such as dynamic contrast enhancement imaging, cardiac imaging, and MR angiography. Performing fat suppression in these sequences is usually time consuming and often somewhat ineffective, due to the relatively short T1 and long T2 of fat. A novel rapid fat suppression strategy using spectrally selective pulses is introduced and compared with clinically popular sequences such as fat presaturated fast field echo (FFE) and turbo field echo (TFE) and binomial water-selective spatial-spectral excitation (SSE, or SPSP excitation) FFE. The new strategy combines fat presaturation with low-order binomial water-selective SSE pulses in a TFE sequence. This enables the use of a long echo train length to decrease exam time, but without creation of excess fat signal contamination of the resultant images. The fat nullification is also more reliable as fat signals in central k-space data are suppressed twice. An implementation of this strategy is compared with traditional methods in both phantom and human studies, confirming that the new technique provides strong fat suppression with few artifacts despite the short scan duration.

Original languageEnglish (US)
Pages (from-to)1569-1574
Number of pages6
JournalMagnetic Resonance in Medicine
Volume54
Issue number6
DOIs
StatePublished - Dec 2005

Fingerprint

Fats
Water
Artifacts
Angiography

Keywords

  • Chemical shift selective imaging
  • Fat suppression
  • Frequency selective
  • Gradient echo
  • MRI
  • Rapid imaging
  • Spatial-spectral excitation

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Novel rapid fat suppression strategy with spectrally selective pulses. / Peng, Qi; McColl, Roderick W.; Wang, Jihong; Weatherall, Paul T.

In: Magnetic Resonance in Medicine, Vol. 54, No. 6, 12.2005, p. 1569-1574.

Research output: Contribution to journalArticle

@article{9c416e8aae5b4de38c9574a7fbae5bd0,
title = "Novel rapid fat suppression strategy with spectrally selective pulses",
abstract = "Short repetition time gradient echo sequences are gaining popularity in clinical applications such as dynamic contrast enhancement imaging, cardiac imaging, and MR angiography. Performing fat suppression in these sequences is usually time consuming and often somewhat ineffective, due to the relatively short T1 and long T2 of fat. A novel rapid fat suppression strategy using spectrally selective pulses is introduced and compared with clinically popular sequences such as fat presaturated fast field echo (FFE) and turbo field echo (TFE) and binomial water-selective spatial-spectral excitation (SSE, or SPSP excitation) FFE. The new strategy combines fat presaturation with low-order binomial water-selective SSE pulses in a TFE sequence. This enables the use of a long echo train length to decrease exam time, but without creation of excess fat signal contamination of the resultant images. The fat nullification is also more reliable as fat signals in central k-space data are suppressed twice. An implementation of this strategy is compared with traditional methods in both phantom and human studies, confirming that the new technique provides strong fat suppression with few artifacts despite the short scan duration.",
keywords = "Chemical shift selective imaging, Fat suppression, Frequency selective, Gradient echo, MRI, Rapid imaging, Spatial-spectral excitation",
author = "Qi Peng and McColl, {Roderick W.} and Jihong Wang and Weatherall, {Paul T.}",
year = "2005",
month = "12",
doi = "10.1002/mrm.20694",
language = "English (US)",
volume = "54",
pages = "1569--1574",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "6",

}

TY - JOUR

T1 - Novel rapid fat suppression strategy with spectrally selective pulses

AU - Peng, Qi

AU - McColl, Roderick W.

AU - Wang, Jihong

AU - Weatherall, Paul T.

PY - 2005/12

Y1 - 2005/12

N2 - Short repetition time gradient echo sequences are gaining popularity in clinical applications such as dynamic contrast enhancement imaging, cardiac imaging, and MR angiography. Performing fat suppression in these sequences is usually time consuming and often somewhat ineffective, due to the relatively short T1 and long T2 of fat. A novel rapid fat suppression strategy using spectrally selective pulses is introduced and compared with clinically popular sequences such as fat presaturated fast field echo (FFE) and turbo field echo (TFE) and binomial water-selective spatial-spectral excitation (SSE, or SPSP excitation) FFE. The new strategy combines fat presaturation with low-order binomial water-selective SSE pulses in a TFE sequence. This enables the use of a long echo train length to decrease exam time, but without creation of excess fat signal contamination of the resultant images. The fat nullification is also more reliable as fat signals in central k-space data are suppressed twice. An implementation of this strategy is compared with traditional methods in both phantom and human studies, confirming that the new technique provides strong fat suppression with few artifacts despite the short scan duration.

AB - Short repetition time gradient echo sequences are gaining popularity in clinical applications such as dynamic contrast enhancement imaging, cardiac imaging, and MR angiography. Performing fat suppression in these sequences is usually time consuming and often somewhat ineffective, due to the relatively short T1 and long T2 of fat. A novel rapid fat suppression strategy using spectrally selective pulses is introduced and compared with clinically popular sequences such as fat presaturated fast field echo (FFE) and turbo field echo (TFE) and binomial water-selective spatial-spectral excitation (SSE, or SPSP excitation) FFE. The new strategy combines fat presaturation with low-order binomial water-selective SSE pulses in a TFE sequence. This enables the use of a long echo train length to decrease exam time, but without creation of excess fat signal contamination of the resultant images. The fat nullification is also more reliable as fat signals in central k-space data are suppressed twice. An implementation of this strategy is compared with traditional methods in both phantom and human studies, confirming that the new technique provides strong fat suppression with few artifacts despite the short scan duration.

KW - Chemical shift selective imaging

KW - Fat suppression

KW - Frequency selective

KW - Gradient echo

KW - MRI

KW - Rapid imaging

KW - Spatial-spectral excitation

UR - http://www.scopus.com/inward/record.url?scp=28444480676&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=28444480676&partnerID=8YFLogxK

U2 - 10.1002/mrm.20694

DO - 10.1002/mrm.20694

M3 - Article

VL - 54

SP - 1569

EP - 1574

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 6

ER -