Observer variability in the assessment of disc degeneration on magnetic resonance images of the lumbar and thoracic spine

R. Raininko, H. Manninen, M. C. Battie, L. E. Gibbons, K. Gill, L. D. Fisher

Research output: Contribution to journalArticle

82 Citations (Scopus)

Abstract

Study Design. Intraobserver and interobserver reproducibility study. Objective. This study investigates the variability in the interpretation of degenerative disc findings using magnetic resonance imaging. Summary of Background Data. Magnetic resonance imaging has been used for years in clinical diagnostics, primarily to investigate disc herniation and spinal stenosis. Less attention has been paid to other disc findings and their assessment reliability. Methods. Three independent readers evaluated magnetic resonance images of the lumbar and the lower and middle thoracic spines of 122 subjects by grading 12 aspects of the intervertebral discs and adjacent endplates using written definitions and example images. Images of 20 subjects were reevaluated for the assessment of intraobserver agreement. Results. Agreement was highest in the lower lumbar and poorest in the middle thoracic spine. Intraobserver agreement was generally fair to excellent for almost all variables in the lumbar and lower thoracic spine (most intraclass correlation and kappa coefficients for these regions were above 0.70). Interobserver agreement was notably lower than intraobserver agreement, except for osteophytes and endplate defects in some regions. Conclusions. Intraobserver agreement in the evaluation of disc degeneration was at an acceptable level, in general, in the lumbar and lower thoracic spine. However, assessments were substantially more variable between readers, which limits comparisons of evaluations between different readers.

Original languageEnglish (US)
Pages (from-to)1029-1035
Number of pages7
JournalSpine
Volume20
Issue number9
StatePublished - 1995

Fingerprint

Intervertebral Disc Degeneration
Spine
Magnetic Resonance Spectroscopy
Thorax
Magnetic Resonance Imaging
Osteophyte
Spinal Stenosis
Intervertebral Disc

Keywords

  • disc degeneration
  • intervertebral disc
  • magnetic resonance imaging
  • reliability

ASJC Scopus subject areas

  • Physiology
  • Clinical Neurology
  • Orthopedics and Sports Medicine

Cite this

Raininko, R., Manninen, H., Battie, M. C., Gibbons, L. E., Gill, K., & Fisher, L. D. (1995). Observer variability in the assessment of disc degeneration on magnetic resonance images of the lumbar and thoracic spine. Spine, 20(9), 1029-1035.

Observer variability in the assessment of disc degeneration on magnetic resonance images of the lumbar and thoracic spine. / Raininko, R.; Manninen, H.; Battie, M. C.; Gibbons, L. E.; Gill, K.; Fisher, L. D.

In: Spine, Vol. 20, No. 9, 1995, p. 1029-1035.

Research output: Contribution to journalArticle

Raininko, R, Manninen, H, Battie, MC, Gibbons, LE, Gill, K & Fisher, LD 1995, 'Observer variability in the assessment of disc degeneration on magnetic resonance images of the lumbar and thoracic spine', Spine, vol. 20, no. 9, pp. 1029-1035.
Raininko, R. ; Manninen, H. ; Battie, M. C. ; Gibbons, L. E. ; Gill, K. ; Fisher, L. D. / Observer variability in the assessment of disc degeneration on magnetic resonance images of the lumbar and thoracic spine. In: Spine. 1995 ; Vol. 20, No. 9. pp. 1029-1035.
@article{65fed19b866b45d79dbe3346c1953dd5,
title = "Observer variability in the assessment of disc degeneration on magnetic resonance images of the lumbar and thoracic spine",
abstract = "Study Design. Intraobserver and interobserver reproducibility study. Objective. This study investigates the variability in the interpretation of degenerative disc findings using magnetic resonance imaging. Summary of Background Data. Magnetic resonance imaging has been used for years in clinical diagnostics, primarily to investigate disc herniation and spinal stenosis. Less attention has been paid to other disc findings and their assessment reliability. Methods. Three independent readers evaluated magnetic resonance images of the lumbar and the lower and middle thoracic spines of 122 subjects by grading 12 aspects of the intervertebral discs and adjacent endplates using written definitions and example images. Images of 20 subjects were reevaluated for the assessment of intraobserver agreement. Results. Agreement was highest in the lower lumbar and poorest in the middle thoracic spine. Intraobserver agreement was generally fair to excellent for almost all variables in the lumbar and lower thoracic spine (most intraclass correlation and kappa coefficients for these regions were above 0.70). Interobserver agreement was notably lower than intraobserver agreement, except for osteophytes and endplate defects in some regions. Conclusions. Intraobserver agreement in the evaluation of disc degeneration was at an acceptable level, in general, in the lumbar and lower thoracic spine. However, assessments were substantially more variable between readers, which limits comparisons of evaluations between different readers.",
keywords = "disc degeneration, intervertebral disc, magnetic resonance imaging, reliability",
author = "R. Raininko and H. Manninen and Battie, {M. C.} and Gibbons, {L. E.} and K. Gill and Fisher, {L. D.}",
year = "1995",
language = "English (US)",
volume = "20",
pages = "1029--1035",
journal = "Spine",
issn = "0362-2436",
publisher = "Lippincott Williams and Wilkins",
number = "9",

}

TY - JOUR

T1 - Observer variability in the assessment of disc degeneration on magnetic resonance images of the lumbar and thoracic spine

AU - Raininko, R.

AU - Manninen, H.

AU - Battie, M. C.

AU - Gibbons, L. E.

AU - Gill, K.

AU - Fisher, L. D.

PY - 1995

Y1 - 1995

N2 - Study Design. Intraobserver and interobserver reproducibility study. Objective. This study investigates the variability in the interpretation of degenerative disc findings using magnetic resonance imaging. Summary of Background Data. Magnetic resonance imaging has been used for years in clinical diagnostics, primarily to investigate disc herniation and spinal stenosis. Less attention has been paid to other disc findings and their assessment reliability. Methods. Three independent readers evaluated magnetic resonance images of the lumbar and the lower and middle thoracic spines of 122 subjects by grading 12 aspects of the intervertebral discs and adjacent endplates using written definitions and example images. Images of 20 subjects were reevaluated for the assessment of intraobserver agreement. Results. Agreement was highest in the lower lumbar and poorest in the middle thoracic spine. Intraobserver agreement was generally fair to excellent for almost all variables in the lumbar and lower thoracic spine (most intraclass correlation and kappa coefficients for these regions were above 0.70). Interobserver agreement was notably lower than intraobserver agreement, except for osteophytes and endplate defects in some regions. Conclusions. Intraobserver agreement in the evaluation of disc degeneration was at an acceptable level, in general, in the lumbar and lower thoracic spine. However, assessments were substantially more variable between readers, which limits comparisons of evaluations between different readers.

AB - Study Design. Intraobserver and interobserver reproducibility study. Objective. This study investigates the variability in the interpretation of degenerative disc findings using magnetic resonance imaging. Summary of Background Data. Magnetic resonance imaging has been used for years in clinical diagnostics, primarily to investigate disc herniation and spinal stenosis. Less attention has been paid to other disc findings and their assessment reliability. Methods. Three independent readers evaluated magnetic resonance images of the lumbar and the lower and middle thoracic spines of 122 subjects by grading 12 aspects of the intervertebral discs and adjacent endplates using written definitions and example images. Images of 20 subjects were reevaluated for the assessment of intraobserver agreement. Results. Agreement was highest in the lower lumbar and poorest in the middle thoracic spine. Intraobserver agreement was generally fair to excellent for almost all variables in the lumbar and lower thoracic spine (most intraclass correlation and kappa coefficients for these regions were above 0.70). Interobserver agreement was notably lower than intraobserver agreement, except for osteophytes and endplate defects in some regions. Conclusions. Intraobserver agreement in the evaluation of disc degeneration was at an acceptable level, in general, in the lumbar and lower thoracic spine. However, assessments were substantially more variable between readers, which limits comparisons of evaluations between different readers.

KW - disc degeneration

KW - intervertebral disc

KW - magnetic resonance imaging

KW - reliability

UR - http://www.scopus.com/inward/record.url?scp=0028952216&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028952216&partnerID=8YFLogxK

M3 - Article

C2 - 7631232

AN - SCOPUS:0028952216

VL - 20

SP - 1029

EP - 1035

JO - Spine

JF - Spine

SN - 0362-2436

IS - 9

ER -