TY - JOUR
T1 - Personalized assessment of kV cone beam computed tomography doses in image-guided radiotherapy of pediatric cancer patients
AU - Zhang, Yibao
AU - Yan, Yulong
AU - Nath, Ravinder
AU - Bao, Shanglian
AU - Deng, Jun
N1 - Funding Information:
This work was supported in part by National Basic Research Subject (973) of China (no. 2011CB707701 ), China Scholarship Council (no. 2010601107 ), and Joint Research Foundation of Beijing Education Committee of China (no. JD100010607 ).
Copyright:
Copyright 2012 Elsevier B.V., All rights reserved.
PY - 2012/8/1
Y1 - 2012/8/1
N2 - Purpose: To develop a quantitative method for the estimation of kV cone beam computed tomography (kVCBCT) doses in pediatric patients undergoing image-guided radiotherapy. Methods and Materials: Forty-two children were retrospectively analyzed in subgroups of different scanned regions: one group in the head-and-neck and the other group in the pelvis. Critical structures in planning CT images were delineated on an Eclipse treatment planning system before being converted into CT phantoms for Monte Carlo simulations. A benchmarked EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions of kVCBCT scans with full-fan high-quality head or half-fan pelvis protocols predefined by the manufacturer. Based on planning CT images and structures exported in DICOM RT format, occipital-frontal circumferences (OFC) were calculated for head-and-neck patients using DICOMan software. Similarly, hip circumferences (HIP) were acquired for the pelvic group. Correlations between mean organ doses and age, weight, OFC, and HIP values were analyzed with SigmaPlot software suite, where regression performances were analyzed with relative dose differences (RDD) and coefficients of determination (R 2). Results: kVCBCT-contributed mean doses to all critical structures decreased monotonically with studied parameters, with a steeper decrease in the pelvis than in the head. Empirical functions have been developed for a dose estimation of the major organs at risk in the head and pelvis, respectively. If evaluated with physical parameters other than age, a mean RDD of up to 7.9% was observed for all the structures in our population of 42 patients. Conclusions: kVCBCT doses are highly correlated with patient size. According to this study, weight can be used as a primary index for dose assessment in both head and pelvis scans, while OFC and HIP may serve as secondary indices for dose estimation in corresponding regions. With the proposed empirical functions, it is possible to perform an individualized quantitative dose assessment of kVCBCT scans.
AB - Purpose: To develop a quantitative method for the estimation of kV cone beam computed tomography (kVCBCT) doses in pediatric patients undergoing image-guided radiotherapy. Methods and Materials: Forty-two children were retrospectively analyzed in subgroups of different scanned regions: one group in the head-and-neck and the other group in the pelvis. Critical structures in planning CT images were delineated on an Eclipse treatment planning system before being converted into CT phantoms for Monte Carlo simulations. A benchmarked EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions of kVCBCT scans with full-fan high-quality head or half-fan pelvis protocols predefined by the manufacturer. Based on planning CT images and structures exported in DICOM RT format, occipital-frontal circumferences (OFC) were calculated for head-and-neck patients using DICOMan software. Similarly, hip circumferences (HIP) were acquired for the pelvic group. Correlations between mean organ doses and age, weight, OFC, and HIP values were analyzed with SigmaPlot software suite, where regression performances were analyzed with relative dose differences (RDD) and coefficients of determination (R 2). Results: kVCBCT-contributed mean doses to all critical structures decreased monotonically with studied parameters, with a steeper decrease in the pelvis than in the head. Empirical functions have been developed for a dose estimation of the major organs at risk in the head and pelvis, respectively. If evaluated with physical parameters other than age, a mean RDD of up to 7.9% was observed for all the structures in our population of 42 patients. Conclusions: kVCBCT doses are highly correlated with patient size. According to this study, weight can be used as a primary index for dose assessment in both head and pelvis scans, while OFC and HIP may serve as secondary indices for dose estimation in corresponding regions. With the proposed empirical functions, it is possible to perform an individualized quantitative dose assessment of kVCBCT scans.
KW - Image-guided radiotherapy
KW - Imaging dose
KW - Monte Carlo simulation
KW - Pediatric patients
KW - kVCBCT
UR - http://www.scopus.com/inward/record.url?scp=84863512814&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84863512814&partnerID=8YFLogxK
U2 - 10.1016/j.ijrobp.2011.10.072
DO - 10.1016/j.ijrobp.2011.10.072
M3 - Article
C2 - 22285667
AN - SCOPUS:84863512814
SN - 0360-3016
VL - 83
SP - 1649
EP - 1654
JO - International Journal of Radiation Oncology Biology Physics
JF - International Journal of Radiation Oncology Biology Physics
IS - 5
ER -