Abstract

Objectives/Hypothesis: The aims of this study were to investigate short- and long-term rates of hearing preservation after cochlear implantation and identify factors that impact hearing preservation. Study Design: Retrospective review. Methods: Patients undergoing cochlear implantation with conventional-length electrodes and air-conduction thresholds ≤80 dB HL at 250 Hz preoperatively were included. Hearing preservation was defined as air-conduction thresholds ≤80 dB HL at 250 Hz. Results: The sample included 196 patients (225 implants). Overall, the rate of short-term hearing preservation was 38% (84/225), with 18% (33/188) of patients preserving hearing long term. Multivariate analysis showed better preoperative hearing was predictive of hearing preservation at short (odds ratio [OR]: 0.93, 95% confidence interval [CI]: 0.91-0.95, P <.001) and long-term follow-up (OR: 0.94, 95% CI: 0.91-0.97, P <.001). Lateral wall electrodes and mid-scala electrodes had 3.4 (95% CI: 1.4-8.6, P =.009) and 5.6-times (95% CI: 1.8-17.3, P =.003) higher odds of hearing preservation than perimodiolar arrays at short-term follow-up, respectively. Long-term data revealed better hearing preservation for lateral wall (OR: 7.6, 95% CI: 1.6-36.1, P =.01), but not mid-scala (OR: 3.1, 95% CI: 0.4-23.1, P =.28), when compared to perimodiolar electrodes. Round window/extended round window (RW/ERW) approaches were associated with higher rates of long-term hearing preservation (21%) than cochleostomy approaches (0%) (P = 0.002) on univariate analysis. Conclusions: Better preoperative residual hearing, lateral wall electrodes, and RW/ERW approaches are predictive of higher rates of long-term functional hearing preservation. Level of Evidence: 4. Laryngoscope, 128:482–489, 2018.

Original languageEnglish (US)
Pages (from-to)482-489
Number of pages8
JournalLaryngoscope
Volume128
Issue number2
DOIs
StatePublished - Feb 2018

Keywords

  • Cochlear implant
  • electrode design
  • hearing preservation
  • surgical approach