Abstract

Purpose Pediatric surgeons routinely use fluoroscopy for central venous line (CVL) placement. We examined radiation safety practices and patient/surgeon exposure during fluoroscopic CVL. Methods Fluoroscopic CVL procedures performed by 11 pediatric surgeons in 2012 were reviewed. Fluoroscopic time (FT), patient exposure (mGy), and procedural data were collected. Anthropomorphic phantom simulations were used to calculate scatter and dose (mSv). Surgeons were surveyed regarding safety practices. Results 386 procedures were reviewed. Median FT was 12.8 seconds. Median patient estimated effective dose was 0.13 mSv. Median annual FT per surgeon was 15.4 minutes. Simulations showed no significant difference (p = 0.14) between reported exposures (median 3.5 mGy/minute) and the modeled regression exposures from the C-arm default mode (median 3.4 mGy/minute). Median calculated surgeon exposure was 1.5 mGy/year. Eight of 11 surgeons responded to the survey. Only three reported 100% lead protection and frequent dosimeter use. Conclusion We found nonstandard radiation training, safety practices, and dose monitoring for the 11 surgeons. Based on simulations, the C-arm default setting was typically used instead of low dose. While most CVL procedures have low patient/surgeon doses, every effort should be used to minimize patient and occupational exposure, suggesting the need for formal hands-on training for nonradiologist providers using fluoroscopy.

Original languageEnglish (US)
Pages (from-to)992-995
Number of pages4
JournalJournal of Pediatric Surgery
Volume50
Issue number6
DOIs
StatePublished - Jun 1 2015

Fingerprint

Pediatrics
Safety
Fluoroscopy
Radiation
Radiation Exposure
Surgeons
Occupational Exposure
Patient Safety

Keywords

  • Fluoroscopy
  • Occupational exposure
  • Pediatric
  • Radiation dose

ASJC Scopus subject areas

  • Surgery
  • Pediatrics, Perinatology, and Child Health

Cite this

Radiation exposure and safety practices during pediatric central line placement. / Saeman, Melody R.; Burkhalter, Lorrie S.; Blackburn, Timothy J.; Murphy, Joseph T.

In: Journal of Pediatric Surgery, Vol. 50, No. 6, 01.06.2015, p. 992-995.

Research output: Contribution to journalArticle

@article{e3c147895aee4b36934eb326225fea37,
title = "Radiation exposure and safety practices during pediatric central line placement",
abstract = "Purpose Pediatric surgeons routinely use fluoroscopy for central venous line (CVL) placement. We examined radiation safety practices and patient/surgeon exposure during fluoroscopic CVL. Methods Fluoroscopic CVL procedures performed by 11 pediatric surgeons in 2012 were reviewed. Fluoroscopic time (FT), patient exposure (mGy), and procedural data were collected. Anthropomorphic phantom simulations were used to calculate scatter and dose (mSv). Surgeons were surveyed regarding safety practices. Results 386 procedures were reviewed. Median FT was 12.8 seconds. Median patient estimated effective dose was 0.13 mSv. Median annual FT per surgeon was 15.4 minutes. Simulations showed no significant difference (p = 0.14) between reported exposures (median 3.5 mGy/minute) and the modeled regression exposures from the C-arm default mode (median 3.4 mGy/minute). Median calculated surgeon exposure was 1.5 mGy/year. Eight of 11 surgeons responded to the survey. Only three reported 100{\%} lead protection and frequent dosimeter use. Conclusion We found nonstandard radiation training, safety practices, and dose monitoring for the 11 surgeons. Based on simulations, the C-arm default setting was typically used instead of low dose. While most CVL procedures have low patient/surgeon doses, every effort should be used to minimize patient and occupational exposure, suggesting the need for formal hands-on training for nonradiologist providers using fluoroscopy.",
keywords = "Fluoroscopy, Occupational exposure, Pediatric, Radiation dose",
author = "Saeman, {Melody R.} and Burkhalter, {Lorrie S.} and Blackburn, {Timothy J.} and Murphy, {Joseph T.}",
year = "2015",
month = "6",
day = "1",
doi = "10.1016/j.jpedsurg.2015.03.022",
language = "English (US)",
volume = "50",
pages = "992--995",
journal = "Journal of Pediatric Surgery",
issn = "0022-3468",
publisher = "W.B. Saunders Ltd",
number = "6",

}

TY - JOUR

T1 - Radiation exposure and safety practices during pediatric central line placement

AU - Saeman, Melody R.

AU - Burkhalter, Lorrie S.

AU - Blackburn, Timothy J.

AU - Murphy, Joseph T.

PY - 2015/6/1

Y1 - 2015/6/1

N2 - Purpose Pediatric surgeons routinely use fluoroscopy for central venous line (CVL) placement. We examined radiation safety practices and patient/surgeon exposure during fluoroscopic CVL. Methods Fluoroscopic CVL procedures performed by 11 pediatric surgeons in 2012 were reviewed. Fluoroscopic time (FT), patient exposure (mGy), and procedural data were collected. Anthropomorphic phantom simulations were used to calculate scatter and dose (mSv). Surgeons were surveyed regarding safety practices. Results 386 procedures were reviewed. Median FT was 12.8 seconds. Median patient estimated effective dose was 0.13 mSv. Median annual FT per surgeon was 15.4 minutes. Simulations showed no significant difference (p = 0.14) between reported exposures (median 3.5 mGy/minute) and the modeled regression exposures from the C-arm default mode (median 3.4 mGy/minute). Median calculated surgeon exposure was 1.5 mGy/year. Eight of 11 surgeons responded to the survey. Only three reported 100% lead protection and frequent dosimeter use. Conclusion We found nonstandard radiation training, safety practices, and dose monitoring for the 11 surgeons. Based on simulations, the C-arm default setting was typically used instead of low dose. While most CVL procedures have low patient/surgeon doses, every effort should be used to minimize patient and occupational exposure, suggesting the need for formal hands-on training for nonradiologist providers using fluoroscopy.

AB - Purpose Pediatric surgeons routinely use fluoroscopy for central venous line (CVL) placement. We examined radiation safety practices and patient/surgeon exposure during fluoroscopic CVL. Methods Fluoroscopic CVL procedures performed by 11 pediatric surgeons in 2012 were reviewed. Fluoroscopic time (FT), patient exposure (mGy), and procedural data were collected. Anthropomorphic phantom simulations were used to calculate scatter and dose (mSv). Surgeons were surveyed regarding safety practices. Results 386 procedures were reviewed. Median FT was 12.8 seconds. Median patient estimated effective dose was 0.13 mSv. Median annual FT per surgeon was 15.4 minutes. Simulations showed no significant difference (p = 0.14) between reported exposures (median 3.5 mGy/minute) and the modeled regression exposures from the C-arm default mode (median 3.4 mGy/minute). Median calculated surgeon exposure was 1.5 mGy/year. Eight of 11 surgeons responded to the survey. Only three reported 100% lead protection and frequent dosimeter use. Conclusion We found nonstandard radiation training, safety practices, and dose monitoring for the 11 surgeons. Based on simulations, the C-arm default setting was typically used instead of low dose. While most CVL procedures have low patient/surgeon doses, every effort should be used to minimize patient and occupational exposure, suggesting the need for formal hands-on training for nonradiologist providers using fluoroscopy.

KW - Fluoroscopy

KW - Occupational exposure

KW - Pediatric

KW - Radiation dose

UR - http://www.scopus.com/inward/record.url?scp=84929504863&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84929504863&partnerID=8YFLogxK

U2 - 10.1016/j.jpedsurg.2015.03.022

DO - 10.1016/j.jpedsurg.2015.03.022

M3 - Article

C2 - 25837269

AN - SCOPUS:84929504863

VL - 50

SP - 992

EP - 995

JO - Journal of Pediatric Surgery

JF - Journal of Pediatric Surgery

SN - 0022-3468

IS - 6

ER -