Reliability of digital videometry and acetate tracing in measuring the surface area of cutaneous wounds

Robert P. Wunderlich, Edgar J G Peters, David G. Armstrong, Lawrence A. Lavery

Research output: Contribution to journalArticle

26 Citations (Scopus)

Abstract

Purpose: The purpose of this study was to evaluate the reliability of digital videometry and acetate tracing in the measurement of cutaneous wound area. Methods: Four clinicians used both digital videometry and acetate tracing to measure five wounds that were artificially created on a cadaver specimen. In addition, the clinicians used an analog centimeter ruler to determine a rough estimate of the area of each wound. The wounds were measured a total of five times with each measurement instrument using a non- sequential repeat measures design. Associations between the three wound measurement techniques were examined with Pearson correlation coefficients. In addition, intraclass correlation coefficients (ICC) were calculated for each pair of the three measurement techniques. Results: Correlation between the measurement systems for all raters combined yielded Pearson r-values of 0.93 for ruler and acetate, 0.95 for ruler and digital and 0.97 for acetate and digital. Furthermore, the average measure ICC between acetate and digital was 0.94, between acetate and ruler was 0.76 and between digital and ruler was 0.57. Conclusion: These results suggest that wound area measurements obtained using digital videometry and acetate tracing are very similar and both techniques can be used interchangeably in either clinical or research settings. (C) 2000 Elsevier Science Ireland Ltd.

Original languageEnglish (US)
Pages (from-to)87-92
Number of pages6
JournalDiabetes Research and Clinical Practice
Volume49
Issue number2-3
DOIs
StatePublished - Aug 2000

Fingerprint

Acetates
Skin
Wounds and Injuries
Cadaver
Research

Keywords

  • Diabetes
  • Measurement
  • Neuropathy
  • Reliability
  • Ulcer
  • Wound

ASJC Scopus subject areas

  • Endocrinology
  • Endocrinology, Diabetes and Metabolism

Cite this

Reliability of digital videometry and acetate tracing in measuring the surface area of cutaneous wounds. / Wunderlich, Robert P.; Peters, Edgar J G; Armstrong, David G.; Lavery, Lawrence A.

In: Diabetes Research and Clinical Practice, Vol. 49, No. 2-3, 08.2000, p. 87-92.

Research output: Contribution to journalArticle

@article{ba3314752f4e4b34b7f67e5f1b38bcda,
title = "Reliability of digital videometry and acetate tracing in measuring the surface area of cutaneous wounds",
abstract = "Purpose: The purpose of this study was to evaluate the reliability of digital videometry and acetate tracing in the measurement of cutaneous wound area. Methods: Four clinicians used both digital videometry and acetate tracing to measure five wounds that were artificially created on a cadaver specimen. In addition, the clinicians used an analog centimeter ruler to determine a rough estimate of the area of each wound. The wounds were measured a total of five times with each measurement instrument using a non- sequential repeat measures design. Associations between the three wound measurement techniques were examined with Pearson correlation coefficients. In addition, intraclass correlation coefficients (ICC) were calculated for each pair of the three measurement techniques. Results: Correlation between the measurement systems for all raters combined yielded Pearson r-values of 0.93 for ruler and acetate, 0.95 for ruler and digital and 0.97 for acetate and digital. Furthermore, the average measure ICC between acetate and digital was 0.94, between acetate and ruler was 0.76 and between digital and ruler was 0.57. Conclusion: These results suggest that wound area measurements obtained using digital videometry and acetate tracing are very similar and both techniques can be used interchangeably in either clinical or research settings. (C) 2000 Elsevier Science Ireland Ltd.",
keywords = "Diabetes, Measurement, Neuropathy, Reliability, Ulcer, Wound",
author = "Wunderlich, {Robert P.} and Peters, {Edgar J G} and Armstrong, {David G.} and Lavery, {Lawrence A.}",
year = "2000",
month = "8",
doi = "10.1016/S0168-8227(00)00145-5",
language = "English (US)",
volume = "49",
pages = "87--92",
journal = "Diabetes Research and Clinical Practice",
issn = "0168-8227",
publisher = "Elsevier Ireland Ltd",
number = "2-3",

}

TY - JOUR

T1 - Reliability of digital videometry and acetate tracing in measuring the surface area of cutaneous wounds

AU - Wunderlich, Robert P.

AU - Peters, Edgar J G

AU - Armstrong, David G.

AU - Lavery, Lawrence A.

PY - 2000/8

Y1 - 2000/8

N2 - Purpose: The purpose of this study was to evaluate the reliability of digital videometry and acetate tracing in the measurement of cutaneous wound area. Methods: Four clinicians used both digital videometry and acetate tracing to measure five wounds that were artificially created on a cadaver specimen. In addition, the clinicians used an analog centimeter ruler to determine a rough estimate of the area of each wound. The wounds were measured a total of five times with each measurement instrument using a non- sequential repeat measures design. Associations between the three wound measurement techniques were examined with Pearson correlation coefficients. In addition, intraclass correlation coefficients (ICC) were calculated for each pair of the three measurement techniques. Results: Correlation between the measurement systems for all raters combined yielded Pearson r-values of 0.93 for ruler and acetate, 0.95 for ruler and digital and 0.97 for acetate and digital. Furthermore, the average measure ICC between acetate and digital was 0.94, between acetate and ruler was 0.76 and between digital and ruler was 0.57. Conclusion: These results suggest that wound area measurements obtained using digital videometry and acetate tracing are very similar and both techniques can be used interchangeably in either clinical or research settings. (C) 2000 Elsevier Science Ireland Ltd.

AB - Purpose: The purpose of this study was to evaluate the reliability of digital videometry and acetate tracing in the measurement of cutaneous wound area. Methods: Four clinicians used both digital videometry and acetate tracing to measure five wounds that were artificially created on a cadaver specimen. In addition, the clinicians used an analog centimeter ruler to determine a rough estimate of the area of each wound. The wounds were measured a total of five times with each measurement instrument using a non- sequential repeat measures design. Associations between the three wound measurement techniques were examined with Pearson correlation coefficients. In addition, intraclass correlation coefficients (ICC) were calculated for each pair of the three measurement techniques. Results: Correlation between the measurement systems for all raters combined yielded Pearson r-values of 0.93 for ruler and acetate, 0.95 for ruler and digital and 0.97 for acetate and digital. Furthermore, the average measure ICC between acetate and digital was 0.94, between acetate and ruler was 0.76 and between digital and ruler was 0.57. Conclusion: These results suggest that wound area measurements obtained using digital videometry and acetate tracing are very similar and both techniques can be used interchangeably in either clinical or research settings. (C) 2000 Elsevier Science Ireland Ltd.

KW - Diabetes

KW - Measurement

KW - Neuropathy

KW - Reliability

KW - Ulcer

KW - Wound

UR - http://www.scopus.com/inward/record.url?scp=0033848082&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033848082&partnerID=8YFLogxK

U2 - 10.1016/S0168-8227(00)00145-5

DO - 10.1016/S0168-8227(00)00145-5

M3 - Article

C2 - 10963818

AN - SCOPUS:0033848082

VL - 49

SP - 87

EP - 92

JO - Diabetes Research and Clinical Practice

JF - Diabetes Research and Clinical Practice

SN - 0168-8227

IS - 2-3

ER -