Reproducibility of thoracic and abdominal aortic wall measurements with three-dimensional, variable flip angle (SPACE) MRI

Georgeta Mihai, Juliet Varghese, Bo Lu, Hong Zhu, Orlando P. Simonetti, Sanjay Rajagopalan

Research output: Contribution to journalArticlepeer-review

16 Scopus citations

Abstract

Purpose: To evaluate the reproducibility and repeatability of high-resolution, isotropic thoracic and abdominal aortic wall measurements, and determine the implications they have on the number of subjects necessary for future clinical trials.

Materials and Methods: Using a T1-weighted threedimensional MRI SPACE sequence, we evaluated the interobserver, intraobserver, and scan-rescan variability of isotropic thoracic and abdominal aortic wall measurements in 15 cardiovascular diseased patients and 6 normal volunteers. Main outcome analyses were intracorrelation coefficient (ICC), mean relative error (mRE), and sample size calculation at 80% power to be used to compare placebo group and treatment group means in future two-arm randomized clinical trials.

Results: Excellent reliability, ICC>0.8 (P<0.001) and small mRE<10% were demonstrated for the interobserver, intraobserver, and scan-rescan variability for all investigated measures: lumen area (LA), outer wall area (OWA), wall area (VWA), total wall volume (TWV), and percentage wall volume (%WV). Sample size calculation revealed slightly different sample size per treatment arm for thoracic and abdominal aorta segments (maximum number of subjects: 352 subjects for thoracic segment versus 421 subjects for abdominal segment for LA at 5% difference, and minimum of 3 thoracic versus 4 abdominal subjects needed for %WV evaluation at 25% difference).

Conclusion: Our study demonstrates the reproducibility and repeatability of SPACE aortic plaque measurements, and gives insight into the number of subjects needed for the design of therapeutic studies in aortic atherosclerosis.

Original languageEnglish (US)
Pages (from-to)202-212
Number of pages11
JournalJournal of Magnetic Resonance Imaging
Volume41
Issue number1
DOIs
StatePublished - Jan 1 2015

Keywords

  • Aorta
  • Atherosclerosis
  • Clinical trial
  • Magnetic resonance imaging
  • Reproducibility
  • Variable flip angle

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Reproducibility of thoracic and abdominal aortic wall measurements with three-dimensional, variable flip angle (SPACE) MRI'. Together they form a unique fingerprint.

Cite this