Residual thermal damage resulting from pulsed and scanned resurfacing lasers

Eric F. Bernstein, Douglas B. Brown, Jeffrey Kenkel, A. Jay Burns

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

BACKGROUND. Laser resurfacing with rapidly scanned or pulsed carbon dioxide (CO2) lasers has evolved rapidly in recent years. These lasers vaporize small amounts of tissue, while leaving minimal residual thermal damage. OBJECTIVE. To compare the depth of residual thermal damage of two of the most commonly used CO2 laser systems. A rapidly scanned laser was compared to a short-pulse laser system. METHODS. Laser treatment was performed on abdominoplasty specimens prior to removal in four subjects. One, two, or three passes of the two most commonly used energies were administered using each laser system. RESULTS. The depth of thermal damage increased with a greater number of passes with each laser system. Higher energies resulted in greater residual thermal damage with each system after the first pass up to three passes, which was the maximum number of passes administered. Combining the second and third passes, residual thermal damage was remarkably similar when comparing the pulsed and scanned lasers. CONCLUSIONS. The most commonly used energy settings of two lasers with very different modes of action resulted in remarkably similar depths of thermal damage, suggesting that the zone of thermal damage may correlate with clinical outcome. In addition, the zone of thermal damage enlarges as the number of passes increases from one to three.

Original languageEnglish (US)
Pages (from-to)739-744
Number of pages6
JournalDermatologic Surgery
Volume25
Issue number10
DOIs
StatePublished - 1999

Fingerprint

Lasers
Hot Temperature
Gas Lasers
Abdominoplasty

ASJC Scopus subject areas

  • Dermatology
  • Surgery

Cite this

Residual thermal damage resulting from pulsed and scanned resurfacing lasers. / Bernstein, Eric F.; Brown, Douglas B.; Kenkel, Jeffrey; Burns, A. Jay.

In: Dermatologic Surgery, Vol. 25, No. 10, 1999, p. 739-744.

Research output: Contribution to journalArticle

Bernstein, Eric F. ; Brown, Douglas B. ; Kenkel, Jeffrey ; Burns, A. Jay. / Residual thermal damage resulting from pulsed and scanned resurfacing lasers. In: Dermatologic Surgery. 1999 ; Vol. 25, No. 10. pp. 739-744.
@article{55583d93d25248708a7a7379b499caf1,
title = "Residual thermal damage resulting from pulsed and scanned resurfacing lasers",
abstract = "BACKGROUND. Laser resurfacing with rapidly scanned or pulsed carbon dioxide (CO2) lasers has evolved rapidly in recent years. These lasers vaporize small amounts of tissue, while leaving minimal residual thermal damage. OBJECTIVE. To compare the depth of residual thermal damage of two of the most commonly used CO2 laser systems. A rapidly scanned laser was compared to a short-pulse laser system. METHODS. Laser treatment was performed on abdominoplasty specimens prior to removal in four subjects. One, two, or three passes of the two most commonly used energies were administered using each laser system. RESULTS. The depth of thermal damage increased with a greater number of passes with each laser system. Higher energies resulted in greater residual thermal damage with each system after the first pass up to three passes, which was the maximum number of passes administered. Combining the second and third passes, residual thermal damage was remarkably similar when comparing the pulsed and scanned lasers. CONCLUSIONS. The most commonly used energy settings of two lasers with very different modes of action resulted in remarkably similar depths of thermal damage, suggesting that the zone of thermal damage may correlate with clinical outcome. In addition, the zone of thermal damage enlarges as the number of passes increases from one to three.",
author = "Bernstein, {Eric F.} and Brown, {Douglas B.} and Jeffrey Kenkel and Burns, {A. Jay}",
year = "1999",
doi = "10.1046/j.1524-4725.1999.99024.x",
language = "English (US)",
volume = "25",
pages = "739--744",
journal = "Dermatologic Surgery",
issn = "1076-0512",
publisher = "Wiley-Blackwell",
number = "10",

}

TY - JOUR

T1 - Residual thermal damage resulting from pulsed and scanned resurfacing lasers

AU - Bernstein, Eric F.

AU - Brown, Douglas B.

AU - Kenkel, Jeffrey

AU - Burns, A. Jay

PY - 1999

Y1 - 1999

N2 - BACKGROUND. Laser resurfacing with rapidly scanned or pulsed carbon dioxide (CO2) lasers has evolved rapidly in recent years. These lasers vaporize small amounts of tissue, while leaving minimal residual thermal damage. OBJECTIVE. To compare the depth of residual thermal damage of two of the most commonly used CO2 laser systems. A rapidly scanned laser was compared to a short-pulse laser system. METHODS. Laser treatment was performed on abdominoplasty specimens prior to removal in four subjects. One, two, or three passes of the two most commonly used energies were administered using each laser system. RESULTS. The depth of thermal damage increased with a greater number of passes with each laser system. Higher energies resulted in greater residual thermal damage with each system after the first pass up to three passes, which was the maximum number of passes administered. Combining the second and third passes, residual thermal damage was remarkably similar when comparing the pulsed and scanned lasers. CONCLUSIONS. The most commonly used energy settings of two lasers with very different modes of action resulted in remarkably similar depths of thermal damage, suggesting that the zone of thermal damage may correlate with clinical outcome. In addition, the zone of thermal damage enlarges as the number of passes increases from one to three.

AB - BACKGROUND. Laser resurfacing with rapidly scanned or pulsed carbon dioxide (CO2) lasers has evolved rapidly in recent years. These lasers vaporize small amounts of tissue, while leaving minimal residual thermal damage. OBJECTIVE. To compare the depth of residual thermal damage of two of the most commonly used CO2 laser systems. A rapidly scanned laser was compared to a short-pulse laser system. METHODS. Laser treatment was performed on abdominoplasty specimens prior to removal in four subjects. One, two, or three passes of the two most commonly used energies were administered using each laser system. RESULTS. The depth of thermal damage increased with a greater number of passes with each laser system. Higher energies resulted in greater residual thermal damage with each system after the first pass up to three passes, which was the maximum number of passes administered. Combining the second and third passes, residual thermal damage was remarkably similar when comparing the pulsed and scanned lasers. CONCLUSIONS. The most commonly used energy settings of two lasers with very different modes of action resulted in remarkably similar depths of thermal damage, suggesting that the zone of thermal damage may correlate with clinical outcome. In addition, the zone of thermal damage enlarges as the number of passes increases from one to three.

UR - http://www.scopus.com/inward/record.url?scp=0032862170&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032862170&partnerID=8YFLogxK

U2 - 10.1046/j.1524-4725.1999.99024.x

DO - 10.1046/j.1524-4725.1999.99024.x

M3 - Article

VL - 25

SP - 739

EP - 744

JO - Dermatologic Surgery

JF - Dermatologic Surgery

SN - 1076-0512

IS - 10

ER -