Microwave imaging (MI) technology has come a long way to introduce a noninvasive, inexpensive, fast, convenient, and safe screening tool for clinical breast monitoring. However, there is a niche between the existing understanding of MI by engineers versus clinicians. Our manuscript targets that niche and highlights the state of the art in MI technology compared to the existing breast cancer detection modalities (mammography, ultrasound, molecular imaging, and magnetic resonance). The significance of our review article is in consolidation of up-to-date breast clinician views with the practical needs and engineering challenges of a novel breast screening modality. We summarize breast tissue abnormalities and highlight the benefits as well as potential drawbacks of the MI as a cancer detection methodology. Our goal is to present an article that MI researchers as well as practitioners in the field can use to assess the viability of the MI technology as a competing or complementary modality to the existing means of breast cancer screening.

Original languageEnglish (US)
Pages (from-to)e446-e458
JournalMedical Physics
Volume44
Issue number12
DOIs
StatePublished - Dec 1 2017

Fingerprint

Microwaves
Breast
Technology
Breast Neoplasms
Molecular Imaging
Manuscripts
Mammography
Early Detection of Cancer
Ultrasonography
Magnetic Resonance Spectroscopy
Research Personnel
Neoplasms

Keywords

  • breast monitoring
  • ionizing radiation
  • mammography
  • microwave imaging

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

Review of breast screening : Toward clinical realization of microwave imaging: Toward. / Modiri, Arezoo; Goudreau, Sally; Rahimi, Asal; Kiasaleh, Kamran.

In: Medical Physics, Vol. 44, No. 12, 01.12.2017, p. e446-e458.

Research output: Contribution to journalReview article

@article{3ca921ba4eca4905adfdfa42dc78dd64,
title = "Review of breast screening: Toward clinical realization of microwave imaging: Toward",
abstract = "Microwave imaging (MI) technology has come a long way to introduce a noninvasive, inexpensive, fast, convenient, and safe screening tool for clinical breast monitoring. However, there is a niche between the existing understanding of MI by engineers versus clinicians. Our manuscript targets that niche and highlights the state of the art in MI technology compared to the existing breast cancer detection modalities (mammography, ultrasound, molecular imaging, and magnetic resonance). The significance of our review article is in consolidation of up-to-date breast clinician views with the practical needs and engineering challenges of a novel breast screening modality. We summarize breast tissue abnormalities and highlight the benefits as well as potential drawbacks of the MI as a cancer detection methodology. Our goal is to present an article that MI researchers as well as practitioners in the field can use to assess the viability of the MI technology as a competing or complementary modality to the existing means of breast cancer screening.",
keywords = "breast monitoring, ionizing radiation, mammography, microwave imaging",
author = "Arezoo Modiri and Sally Goudreau and Asal Rahimi and Kamran Kiasaleh",
year = "2017",
month = "12",
day = "1",
doi = "10.1002/mp.12611",
language = "English (US)",
volume = "44",
pages = "e446--e458",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "12",

}

TY - JOUR

T1 - Review of breast screening

T2 - Toward clinical realization of microwave imaging: Toward

AU - Modiri, Arezoo

AU - Goudreau, Sally

AU - Rahimi, Asal

AU - Kiasaleh, Kamran

PY - 2017/12/1

Y1 - 2017/12/1

N2 - Microwave imaging (MI) technology has come a long way to introduce a noninvasive, inexpensive, fast, convenient, and safe screening tool for clinical breast monitoring. However, there is a niche between the existing understanding of MI by engineers versus clinicians. Our manuscript targets that niche and highlights the state of the art in MI technology compared to the existing breast cancer detection modalities (mammography, ultrasound, molecular imaging, and magnetic resonance). The significance of our review article is in consolidation of up-to-date breast clinician views with the practical needs and engineering challenges of a novel breast screening modality. We summarize breast tissue abnormalities and highlight the benefits as well as potential drawbacks of the MI as a cancer detection methodology. Our goal is to present an article that MI researchers as well as practitioners in the field can use to assess the viability of the MI technology as a competing or complementary modality to the existing means of breast cancer screening.

AB - Microwave imaging (MI) technology has come a long way to introduce a noninvasive, inexpensive, fast, convenient, and safe screening tool for clinical breast monitoring. However, there is a niche between the existing understanding of MI by engineers versus clinicians. Our manuscript targets that niche and highlights the state of the art in MI technology compared to the existing breast cancer detection modalities (mammography, ultrasound, molecular imaging, and magnetic resonance). The significance of our review article is in consolidation of up-to-date breast clinician views with the practical needs and engineering challenges of a novel breast screening modality. We summarize breast tissue abnormalities and highlight the benefits as well as potential drawbacks of the MI as a cancer detection methodology. Our goal is to present an article that MI researchers as well as practitioners in the field can use to assess the viability of the MI technology as a competing or complementary modality to the existing means of breast cancer screening.

KW - breast monitoring

KW - ionizing radiation

KW - mammography

KW - microwave imaging

UR - http://www.scopus.com/inward/record.url?scp=85037850876&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85037850876&partnerID=8YFLogxK

U2 - 10.1002/mp.12611

DO - 10.1002/mp.12611

M3 - Review article

C2 - 28976568

AN - SCOPUS:85037850876

VL - 44

SP - e446-e458

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 12

ER -