Single-camera motion measurement and monitoring for magnetic resonance applications

Chester Wildey, Duncan L. MacFarlane, Aman Goyal, Kaundinya Gopinath, Sergey Cheshkov, Richard Briggs

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

An optically based rigid-body six-degrees of freedom (DOF) measurement system optimized for prospective (real-time) motion correction in magnetic resonance imaging (MRI) applications is described. By optimizing system capabilities to the specific applications requirements, the six-DOF measurement is accomplished using a single camera and simple three-disc fiducial at rates of 50 Hz. The algorithm utilizes successive approximation to solve the three point pose problem for angles close to the origin. Convergence to submicroradian levels occurs within 20 iterations for angles in an approximate halfradian (29°) arc centered on the origin. The overall absolute accuracy of the instrument is 10-100 μm for translational and <100 μrad (0:005 °) for rotational motions. Results for head nodding and speech tasks are presented for subjects in the MR scanner, and the instrument results are compared to standard prospective acquisition correction.

Original languageEnglish (US)
Pages (from-to)2088-2097
Number of pages10
JournalApplied Optics
Volume50
Issue number14
DOIs
StatePublished - May 10 2011

Fingerprint

Magnetic resonance
magnetic resonance
degrees of freedom
Cameras
cameras
Monitoring
rigid structures
scanners
iteration
acquisition
arcs
Imaging techniques
requirements
approximation

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics

Cite this

Wildey, C., MacFarlane, D. L., Goyal, A., Gopinath, K., Cheshkov, S., & Briggs, R. (2011). Single-camera motion measurement and monitoring for magnetic resonance applications. Applied Optics, 50(14), 2088-2097. https://doi.org/10.1364/AO.50.002088

Single-camera motion measurement and monitoring for magnetic resonance applications. / Wildey, Chester; MacFarlane, Duncan L.; Goyal, Aman; Gopinath, Kaundinya; Cheshkov, Sergey; Briggs, Richard.

In: Applied Optics, Vol. 50, No. 14, 10.05.2011, p. 2088-2097.

Research output: Contribution to journalArticle

Wildey, C, MacFarlane, DL, Goyal, A, Gopinath, K, Cheshkov, S & Briggs, R 2011, 'Single-camera motion measurement and monitoring for magnetic resonance applications', Applied Optics, vol. 50, no. 14, pp. 2088-2097. https://doi.org/10.1364/AO.50.002088
Wildey C, MacFarlane DL, Goyal A, Gopinath K, Cheshkov S, Briggs R. Single-camera motion measurement and monitoring for magnetic resonance applications. Applied Optics. 2011 May 10;50(14):2088-2097. https://doi.org/10.1364/AO.50.002088
Wildey, Chester ; MacFarlane, Duncan L. ; Goyal, Aman ; Gopinath, Kaundinya ; Cheshkov, Sergey ; Briggs, Richard. / Single-camera motion measurement and monitoring for magnetic resonance applications. In: Applied Optics. 2011 ; Vol. 50, No. 14. pp. 2088-2097.
@article{a61eea80fc0546ce8b7150a101030094,
title = "Single-camera motion measurement and monitoring for magnetic resonance applications",
abstract = "An optically based rigid-body six-degrees of freedom (DOF) measurement system optimized for prospective (real-time) motion correction in magnetic resonance imaging (MRI) applications is described. By optimizing system capabilities to the specific applications requirements, the six-DOF measurement is accomplished using a single camera and simple three-disc fiducial at rates of 50 Hz. The algorithm utilizes successive approximation to solve the three point pose problem for angles close to the origin. Convergence to submicroradian levels occurs within 20 iterations for angles in an approximate halfradian (29°) arc centered on the origin. The overall absolute accuracy of the instrument is 10-100 μm for translational and <100 μrad (0:005 °) for rotational motions. Results for head nodding and speech tasks are presented for subjects in the MR scanner, and the instrument results are compared to standard prospective acquisition correction.",
author = "Chester Wildey and MacFarlane, {Duncan L.} and Aman Goyal and Kaundinya Gopinath and Sergey Cheshkov and Richard Briggs",
year = "2011",
month = "5",
day = "10",
doi = "10.1364/AO.50.002088",
language = "English (US)",
volume = "50",
pages = "2088--2097",
journal = "Applied Optics",
issn = "0003-6935",
publisher = "The Optical Society",
number = "14",

}

TY - JOUR

T1 - Single-camera motion measurement and monitoring for magnetic resonance applications

AU - Wildey, Chester

AU - MacFarlane, Duncan L.

AU - Goyal, Aman

AU - Gopinath, Kaundinya

AU - Cheshkov, Sergey

AU - Briggs, Richard

PY - 2011/5/10

Y1 - 2011/5/10

N2 - An optically based rigid-body six-degrees of freedom (DOF) measurement system optimized for prospective (real-time) motion correction in magnetic resonance imaging (MRI) applications is described. By optimizing system capabilities to the specific applications requirements, the six-DOF measurement is accomplished using a single camera and simple three-disc fiducial at rates of 50 Hz. The algorithm utilizes successive approximation to solve the three point pose problem for angles close to the origin. Convergence to submicroradian levels occurs within 20 iterations for angles in an approximate halfradian (29°) arc centered on the origin. The overall absolute accuracy of the instrument is 10-100 μm for translational and <100 μrad (0:005 °) for rotational motions. Results for head nodding and speech tasks are presented for subjects in the MR scanner, and the instrument results are compared to standard prospective acquisition correction.

AB - An optically based rigid-body six-degrees of freedom (DOF) measurement system optimized for prospective (real-time) motion correction in magnetic resonance imaging (MRI) applications is described. By optimizing system capabilities to the specific applications requirements, the six-DOF measurement is accomplished using a single camera and simple three-disc fiducial at rates of 50 Hz. The algorithm utilizes successive approximation to solve the three point pose problem for angles close to the origin. Convergence to submicroradian levels occurs within 20 iterations for angles in an approximate halfradian (29°) arc centered on the origin. The overall absolute accuracy of the instrument is 10-100 μm for translational and <100 μrad (0:005 °) for rotational motions. Results for head nodding and speech tasks are presented for subjects in the MR scanner, and the instrument results are compared to standard prospective acquisition correction.

UR - http://www.scopus.com/inward/record.url?scp=79958758630&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79958758630&partnerID=8YFLogxK

U2 - 10.1364/AO.50.002088

DO - 10.1364/AO.50.002088

M3 - Article

C2 - 21556110

AN - SCOPUS:79958758630

VL - 50

SP - 2088

EP - 2097

JO - Applied Optics

JF - Applied Optics

SN - 0003-6935

IS - 14

ER -