Sonar fetal cephalometry

Comparison of bistable with gray scale and real-time techniques

Rigoberto Santos-Ramos, Johann H. Duenhoelter, Joan S. Reisch

Research output: Contribution to journalArticle

Abstract

The fetal biparietal diameter was measured simultaneously with B-scan bistable and gray scale techniques and subsequently with real-time ultrasonography. Measurements were made from outer table to outer table with the bistable technique, which has been proven to be accurate and reliable. With the gray scale and real-time modalities, distances were measured between several landmarks from the same image. Of all measurements taken from gray scale and realtime images, those between the centers of each band outlining the fetal skull showed the best correlation and the closest values to measurements using the standard bistable technique. Discrepancies exceeded 2 mm in only 5% with the gray scale and in 2% with the real-time technique. Using the measurement between outer and inner aspects of the cephalic band, the percentages of discrepancies exceeding 2 mm were 7% with gray scale and 6% with real time.

Original languageEnglish (US)
Pages (from-to)805-807
Number of pages3
JournalAmerican Journal of Obstetrics and Gynecology
Volume136
Issue number6
StatePublished - Mar 15 1980

Fingerprint

Cephalometry
Skull
Ultrasonography
Head

ASJC Scopus subject areas

  • Medicine(all)
  • Obstetrics and Gynecology

Cite this

Sonar fetal cephalometry : Comparison of bistable with gray scale and real-time techniques. / Santos-Ramos, Rigoberto; Duenhoelter, Johann H.; Reisch, Joan S.

In: American Journal of Obstetrics and Gynecology, Vol. 136, No. 6, 15.03.1980, p. 805-807.

Research output: Contribution to journalArticle

@article{5cbeb7f38fbc48ec9b0e73fd0dbeace2,
title = "Sonar fetal cephalometry: Comparison of bistable with gray scale and real-time techniques",
abstract = "The fetal biparietal diameter was measured simultaneously with B-scan bistable and gray scale techniques and subsequently with real-time ultrasonography. Measurements were made from outer table to outer table with the bistable technique, which has been proven to be accurate and reliable. With the gray scale and real-time modalities, distances were measured between several landmarks from the same image. Of all measurements taken from gray scale and realtime images, those between the centers of each band outlining the fetal skull showed the best correlation and the closest values to measurements using the standard bistable technique. Discrepancies exceeded 2 mm in only 5{\%} with the gray scale and in 2{\%} with the real-time technique. Using the measurement between outer and inner aspects of the cephalic band, the percentages of discrepancies exceeding 2 mm were 7{\%} with gray scale and 6{\%} with real time.",
author = "Rigoberto Santos-Ramos and Duenhoelter, {Johann H.} and Reisch, {Joan S.}",
year = "1980",
month = "3",
day = "15",
language = "English (US)",
volume = "136",
pages = "805--807",
journal = "American Journal of Obstetrics and Gynecology",
issn = "0002-9378",
publisher = "Mosby Inc.",
number = "6",

}

TY - JOUR

T1 - Sonar fetal cephalometry

T2 - Comparison of bistable with gray scale and real-time techniques

AU - Santos-Ramos, Rigoberto

AU - Duenhoelter, Johann H.

AU - Reisch, Joan S.

PY - 1980/3/15

Y1 - 1980/3/15

N2 - The fetal biparietal diameter was measured simultaneously with B-scan bistable and gray scale techniques and subsequently with real-time ultrasonography. Measurements were made from outer table to outer table with the bistable technique, which has been proven to be accurate and reliable. With the gray scale and real-time modalities, distances were measured between several landmarks from the same image. Of all measurements taken from gray scale and realtime images, those between the centers of each band outlining the fetal skull showed the best correlation and the closest values to measurements using the standard bistable technique. Discrepancies exceeded 2 mm in only 5% with the gray scale and in 2% with the real-time technique. Using the measurement between outer and inner aspects of the cephalic band, the percentages of discrepancies exceeding 2 mm were 7% with gray scale and 6% with real time.

AB - The fetal biparietal diameter was measured simultaneously with B-scan bistable and gray scale techniques and subsequently with real-time ultrasonography. Measurements were made from outer table to outer table with the bistable technique, which has been proven to be accurate and reliable. With the gray scale and real-time modalities, distances were measured between several landmarks from the same image. Of all measurements taken from gray scale and realtime images, those between the centers of each band outlining the fetal skull showed the best correlation and the closest values to measurements using the standard bistable technique. Discrepancies exceeded 2 mm in only 5% with the gray scale and in 2% with the real-time technique. Using the measurement between outer and inner aspects of the cephalic band, the percentages of discrepancies exceeding 2 mm were 7% with gray scale and 6% with real time.

UR - http://www.scopus.com/inward/record.url?scp=0018842222&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0018842222&partnerID=8YFLogxK

M3 - Article

VL - 136

SP - 805

EP - 807

JO - American Journal of Obstetrics and Gynecology

JF - American Journal of Obstetrics and Gynecology

SN - 0002-9378

IS - 6

ER -